Adaptec 51645 Скачать руководство пользователя страница 56

Chapter 8: Installing the Driver on an Existing Operating System

56

Installing on Windows

Follow the instructions in this section for your version of Windows.

Installing on Windows Server 2003 or Windows XP

To install the driver on Windows:

1

Start or restart Windows.

The Found New Hardware Wizard opens and searches for the driver.

2

Insert the driver disk, select 

Floppy drive

, then click 

Next

.

3

Click 

Next

, then click 

Next

 again.

4

Follow the on-screen instructions to complete the driver installation.

5

Remove the driver disk and restart your computer.

6

Continue with 

Managing Your Storage Space

 on page 59

.

Installing with Windows Server 2008 or Windows Vista

1

Start or restart Windows.

The Found New Hardware Wizard opens and searches for the driver.

2

Insert the driver disk, then select 

Locate and Install Driver Software...

. and 

Don’t Search 

Online

.

3

Click 

Next

, then click 

Close

.

4

When the installation is complete, remove the driver disk and restart your computer.

5

Continue with 

Managing Your Storage Space

 on page 59

.

Installing on Red Hat or SUSE Linux

To install the module on Red Hat or SUSE Linux:

1

Insert and mount the RAID Installation CD:

Red Hat:

mount /dev/cdrom /mnt/cdrom

SUSE:

mount /dev/cdrom /media/cdrom

2

Install the module RPM:

rpm -Uvh 

mount-point/xxx/yyy.rpm

where 

mount-point

 is the specific mount point on the Linux system, 

xxx

 is the driver path, 

and 

yyy.rpm

 is the rpm file.

3

Reboot your computer to ensure the driver loaded correctly.

4

Run fdisk, mkfs, and create mount points for any new disk drives.

5

Continue with 

Managing Your Storage Space

 on page 59

.

Содержание 51645

Страница 1: ...Installation and User s Guide Serial Attached SCSI RAID Controllers...

Страница 2: ...s a trademark of Red Hat Inc in the US and other countries used under license All other trademarks are the property of their respective owners Changes The material in this document is for information...

Страница 3: ...act information North America Visit our Web site at www adaptec com Search the Adaptec Support Knowledgebase ASK at ask adaptec com for articles troubleshooting tips and frequently asked questions for...

Страница 4: ...e Adaptec at 691 South Milpitas Boulevard Milpitas CA 95035 800 959 7274 5 THIS LIMITED WARRANTY DOES NOT EXTEND TO ANY PRODUCT WHICH HAS BEEN DAMAGED AS A RESULT OF ACCIDENT MISUSE ABUSE OR AS A RESU...

Страница 5: ...en tested and found to comply with EMC Directive 89 336 EEC as amended by 92 31 EEC and 93 68 EEC in accordance with EN55022 1998 A1 2000 A2 2003 Emissions EN55024 1998 A1 2001 A2 2003 Immunity EN6100...

Страница 6: ...ures 16 Advanced Data Protection Suite 16 Adding a Battery Backup Module 17 Upgrading the Controller Firmware 17 About the Adaptec RAID 5085 18 About the Adaptec RAID 5405 19 About the Adaptec RAID 54...

Страница 7: ...o a System Backplane 39 Connecting MaxIQ Solid State Drives and other SSDs 40 Connecting External Devices 42 Next Steps 42 Creating a Bootable Array Setting the Boot Controller 44 Creating an Array 44...

Страница 8: ...bout the Adaptec Flash Utility 61 Which Utility Should I Use 61 Solving Problems Troubleshooting Checklist 63 Monitoring Disk Drives Status 63 Silencing the Alarm 63 Recovering from a Disk Drive Failu...

Страница 9: ...eate and Manage Arrays 84 Creating a New Array 84 Managing Existing Arrays 85 Initializing Disk Drives 86 Rescanning Disk Drives 86 Secure Erasing Disk Drives 87 Managing Global Hot Spares 87 Using th...

Страница 10: ...ce Adaptec RAID 5085 LED Connector Specification 111 Adaptec RAID 5405 5405Z LED and I2C Connector Specification 113 Adaptec RAID 5445 5445Z LED and I2C Connector Specification 114 Adaptec RAID 5805 5...

Страница 11: ...view of Serial Attached SCSI SAS and Redundant Array of Independent Disk RAID technology These RAID controller models are described in this Guide Adaptec RAID 5085 Adaptec RAID 5405 5405Z Adaptec RAID...

Страница 12: ...e In DAS environments Adaptec Storage Manager refers to arrays as logical drives Why Your RAID controller creates arrays which your operating system and Adaptec Storage Manager recognizes as logical d...

Страница 13: ...rements In this chapter Kit Contents 14 System Requirements 14 This chapter lists the contents of your Adaptec RAID controller kit and the system requirements that must be met for you to successfully...

Страница 14: ...Windows Server 2003 Enterprise and Standard with SP1 or SP2 32 bit and 64 bit Windows XP with SP1 SP2 or SP3 32 bit and 64 bit Red Hat Enterprise Linux 4 Red Hat Enterprise Linux 5 32 bit and 64 bit...

Страница 15: ...c RAID 5445 20 About the Adaptec RAID 5805 21 About the Adaptec RAID 51245 22 About the Adaptec RAID 51645 23 About the Adaptec RAID 52445 24 About the Adaptec RAID 5405Z 25 About the Adaptec RAID 544...

Страница 16: ...8 Power management of disk drives in your storage space to reduce cooling and electricity costs see page 85 Audible alarm I O statistics logging and automatic forwarding for remote analysis call home...

Страница 17: ...of one Dual Drive Failure Protection RAID 60 A RAID 60 array is similar to a RAID 50 array except that it includes four independent sets of parity data instead of two Adding a Battery Backup Module T...

Страница 18: ...xternal 2 mini SAS x4 SFF 8088 Maximum number of disk drives 8 direct attached or up to 256 with expanders Enclosure Support I2C and SGPIO Serial General Purpose Output Onboard speaker Yes Battery Bac...

Страница 19: ...1 mini SAS x4 SFF 8087 Maximum number of disk drives 4 direct attached or up to 256 with expanders Enclosure Support I2C and SGPIO Onboard speaker Yes Battery Backup Module Adaptec Battery Module 800...

Страница 20: ...ernal 1 mini SAS x4 SFF 8088 external Maximum number of disk drives 8 direct attached or up to 256 with expanders Enclosure Support I2C and SGPIO Onboard speaker Yes Battery Backup Module Adaptec Batt...

Страница 21: ...F 8087 Maximum number of disk drives 8 direct attached or up to 256 with expanders Enclosure Support I2C and SGPIO Onboard speaker Yes Battery Backup Module Adaptec Battery Module 800 800T sold separa...

Страница 22: ...nnectors Internal 3 mini SAS x4 SFF 8087 Connectors Exteneral 1 mini SAS x4 SFF 8088 Maximum number of disk drives 16 direct attached or up to 256 with expanders Enclosure Support I2C and SGPIO Onboar...

Страница 23: ...Internal 4 mini SAS x4 SFF 8087 Connectors Exteneral 1 mini SAS x4 SFF 8088 Maximum number of disk drives 20 direct attached or up to 256 with expanders Enclosure Support I2C and SGPIO Onboard speake...

Страница 24: ...FF 8087 Connectors Exteneral 1 mini SAS x4 SFF 8088 Maximum number of disk drives 28 direct attached or up to 256 with expanders Enclosure Support I2C and SGPIO Onboard speaker Yes Battery Backup Modu...

Страница 25: ...f disk drives 4 direct attached or up to 256 with expanders Enclosure Support I2C and SGPIO Onboard speaker Yes Zero Maintenance Cache Protection Module Adaptec ZMM 100DB daughterboard pre installed A...

Страница 26: ...rives 8 direct attached or up to 256 with expanders Enclosure Support I2C and SGPIO Onboard speaker Yes Zero Maintenance Cache Protection Module Adaptec ZMM 100DB daughterboard pre installed Adaptec Z...

Страница 27: ...ves 8 direct attached or up to 256 with expanders Enclosure Support I2C and SGPIO Onboard speaker Yes Zero Maintenance Cache Protection Module Adaptec ZMM 100DB daughterboard pre installed Adaptec ZMM...

Страница 28: ...width x8 PCIe bus speed 2 5 Gb s Phys Unified Serial Ports 4 Standard cache 128 MB DDR2 Connectors external 1 mini SAS x4 SFF 8088 Maximum number of disk drives 4 direct attached or up to 128 with ex...

Страница 29: ...s speed 2 5 Gb s Phys Unified Serial Ports 4 Standard cache 128 MB DDR2 Connectors internal 1 mini SAS x4 SFF 8087 Maximum number of disk drives 4 direct attached or up to 128 with expanders Enclosure...

Страница 30: ...Installation Options 33 Basic Installation Steps 34 This chapter provides the basic information you need to set up your disk drives and arrays the way you want them It also describes the options you h...

Страница 31: ...disk drives can be included see page 76 RAID 5 Array Stripes data for improved performance and uses parity data to provide redundancy see page 78 RAID 5EE Array Similar to a RAID 5 array but includes...

Страница 32: ...s in the array but the array will be limited to the capacity of the smallest and slowest disk drive For more information about arrays refer to the Adaptec Storage Manager User s Guide or online Help F...

Страница 33: ...choose to create a bootable array and then install your operating system and the controller driver on that array Alternatively you can complete a standard installation where the controller driver is...

Страница 34: ...Set the boot controller see page 44 3 Create a bootable array see page 44 4 Install your operating system and the controller driver see page 48 5 Install Adaptec Storage Manager and begin to manage yo...

Страница 35: ...e You Begin 36 Installing the Controller 36 Connecting Disk Drives to Your Controllers 38 Connecting External Devices 42 Next Steps 42 This chapter explains how to install your Adaptec RAID controller...

Страница 36: ...t zero maintenance cache protection see the following section To install an Adaptec RAID controller with zero maintenance cache protection see page 37 Installing a RAID Controller 1 Turn off your comp...

Страница 37: ...e with your RAID controller and remove the slot cover as shown at right PCIe bus compatibility is marked to the controller figures in About Your RAID Controller on page 15 Caution Touch a grounded met...

Страница 38: ...Your Controllers You can connect SAS disk drives SATA disk drives SATA Solid State Drives SSD and Adaptec MaxIQ Solid State Drives to your SAS RAID controller See www adaptec com compatibility for a...

Страница 39: ...ices on page 42 Connecting to a System Backplane In a backplane connection disk drives and SAS cards are attached to and communicate with each other through a system backplane The number of disk drive...

Страница 40: ...rive tray you must use a bracket SLED which enables the SSD to fit properly not included with MaxIQ SSD kit Note For MaxIQ caching applications Adaptec RAID controllers support Adaptec MaxIQ branded I...

Страница 41: ...ec RAID controllers support a maximum of 256 drives including SSDs for details see page 15 Note The following steps use an Adaptec MaxIQ SSD as an example but the procedure is suitable for any compati...

Страница 42: ...troller to your external device s such as disk drives or disk drive enclosures Adaptec recommends using only Adaptec cables For more information or to purchase cables visit the Adaptec Web site at www...

Страница 43: ...ble 47 This chapter explains how to set your Adaptec controller to be the boot controller and how to create a bootable array Note If you are completing a standard installation onto an existing operati...

Страница 44: ...ation running from a bootable RAID installation CD that you can navigate with your mouse see page 60 ARCCONF Command line utility For instructions refer to the Adaptec RAID Controller Command Line Uti...

Страница 45: ...ning message displays type Y 11 Once the array is created a message displays telling you that the array can now be used Press any key to return to the ACU Menu You can start using the array immediatel...

Страница 46: ...ation CD to complete this task To create a RAID 5 array 1 Insert the Adaptec Storage Manager Installation CD into your CD drive then restart your computer 2 When prompted select the language you want...

Страница 47: ...ogical drive The configuration is saved on the Adaptec controller as an array see page 12 and on the physical disk drives 9 Partition and format your logical drive The logical drive you created appear...

Страница 48: ...51 Installing with SUSE Linux 51 Installing with OpenServer 51 Installing with UnixWare 52 Installing with Solaris 52 Installing with VMware 53 Installing with FreeBSD 53 This chapter explains how to...

Страница 49: ...BIOS so that your computer boots from the CD drive For instructions refer to your computer documentation 2 Turn on your computer then insert the RAID Installation CD included in your RAID controller...

Страница 50: ...computer reads the disk 6 When the Adaptec driver is found press Enter 7 Follow the on screen instructions to complete the installation 8 Continue with Managing Your Storage Space on page 59 Installin...

Страница 51: ...lation CD 2 Restart your computer 3 When the SUSE installation selection screen appears choose the type of installation you want then press the F6 key to indicate the use of a driver disk If F6 is not...

Страница 52: ...more HBA drivers repeat this step 5 When all drivers have loaded select No 6 Complete the UnixWare installation following the instructions included with your operating system 7 Continue with Managing...

Страница 53: ...rom a remote GUI or use the ARCCONF utility See page 61 for more information Installing with FreeBSD Note You will need your FreeBSD Installation CD to complete this task To install the driver when in...

Страница 54: ...indows 56 Installing on Red Hat or SUSE Linux 56 Installing on OpenServer 57 Installing on UnixWare 57 Installing on Solaris 57 Installing on VMware 58 Installing on FreeBSD 58 This chapter explains h...

Страница 55: ...o create a driver disk 1 Set your system BIOS so that your computer boots from the CD drive For instructions refer to your computer documentation 2 Turn on your computer then insert the RAID Installat...

Страница 56: ...s The Found New Hardware Wizard opens and searches for the driver 2 Insert the driver disk then select Locate and Install Driver Software and Don t Search Online 3 Click Next then click Close 4 When t...

Страница 57: ...age 5 When the installation is complete select q to quit the installer 6 Reboot your computer and remove the driver disk 7 Continue with Managing Your Storage Space on page 59 Installing on Solaris To...

Страница 58: ...64607 esx drivers scsi aacraid 1 1 5 2457 i586 rpm Note The rpm version string may differ for your VMware distribution 4 Follow the on screen instructions to save the boot image and run the vmware mki...

Страница 59: ...figuration Utility 61 About the Adaptec Flash Utility 61 Which Utility Should I Use 61 Once you have installed your Adaptec RAID controller disk drives or other devices and device driver you can begin...

Страница 60: ...than the full application If your storage space includes systems that won t be connected to monitors and therefore won t require the user interface you can choose to run the agent only on those syste...

Страница 61: ...text based DOS utility that you can use to update save or verify your RAID controller s firmware BIOS and Non Volatile Random Access Memory NVRAM Caution Although the AFU contains safeguards to preven...

Страница 62: ...hapter Troubleshooting Checklist 63 Silencing the Alarm 63 Recovering from a Disk Drive Failure 64 Resetting the Controller 65 This chapter provides basic troubleshooting information and solutions for...

Страница 63: ...ms If you are still unable to resolve a problem you can find additional troubleshooting information and direction on the Adaptec Web site at www adaptec com or the Support Knowledgebase at ask adaptec...

Страница 64: ...is enabled Data is automatically moved back to its original location once the controller detects that the failed drive has been replaced No action is required Failed Disk Drive Not Protected by a Hot...

Страница 65: ...ide Note In some instances RAID 10 and RAID 50 arrays may survive multiple disk drive failures depending on which disk drives fail Failed Drive in MaxIQ Pool Because Solid State Drives SSD in the MaxI...

Страница 66: ...er see the figures in About Your RAID Controller on page 15 7 Reconnect the power cord power on your computer then boot to the floppy disk containing the AFU exe file see Step 3 8 At the prompt type a...

Страница 67: ...o SAS Cables Look Like 70 How are Disk Drives Identified in SAS 71 What are the SAS Connection Options 71 How is SAS Different from Parallel SCSI 73 This section provides a basic overview of the main...

Страница 68: ...ections or through expander devices SAS cards can typically support up to 128 end devices and can communicate with both SAS and SATA devices You can add 128 end devices or even more with the use of SA...

Страница 69: ...link is established from a phy in one port to a phy in the other port As shown in the figure above a wide port can support multiple independent links simultaneously Phys are internal within SAS conne...

Страница 70: ...esses and SAS addresses cannot be modified What s a SAS Connector A SAS or mini SAS connector is the physical plug or receptacle that you see on a SAS device It s what you plug a SAS cable into or the...

Страница 71: ...mini SAS cables One disk drive is attached to one SAS mini SAS connector with one SAS mini SAS cable or multiple disk drives are attached to one SAS mini SAS connector with one fan out cable The figur...

Страница 72: ...refer to the STA Web site at www scsita org You can connect up to 128 SAS ports to an edge expander A single edge expander can therefore support up to 128 SAS addresses You can connect up to 128 edge...

Страница 73: ...een the two interfaces Parallel SCSI Serial Attached SCSI Parallel interface Serial interface Maximum speed 320 MB sec shared by all devices on the bus Maximum speed 300 MB sec per phy when in half du...

Страница 74: ...Selecting the Best RAID Level 82 When you create arrays or logical drives you can assign a RAID level to protect your data Each RAID level offers a unique combination of performance and redundancy RAI...

Страница 75: ...qual sized sections However RAID 0 arrays do not maintain redundant data so they offer no data protection Compared to an equal sized group of independent disks a RAID 0 array provides improved I O per...

Страница 76: ...nced Arrays A RAID 1 Enhanced RAID 1E array also known as a striped mirror is similar to a RAID 1 array except that data is both mirrored and striped and more disk drives can be included A RAID 1E arr...

Страница 77: ...ive in the array For instance an array with two 250 GB disk drives and two 400 GB disk drives can create two mirrored drive segments of 250 GB for a total of 500 GB for the array as shown in this figu...

Страница 78: ...iped evenly across the disk drives with the stored data Drive segment size is limited to the size of the smallest disk drive in the array For instance an array with two 250 GB disk drives and two 400...

Страница 79: ...t following a disk drive failure A RAID 5EE array protects your data and increases read and write speeds However capacity is reduced by two disk drives worth of space which is for parity data and spar...

Страница 80: ...the size of the smallest disk drive in the array For example three 250 GB disk drives and three 400 GB disk drives comprise two equal sized RAID 5 arrays with 500 GB of stored data and 250 GB of parit...

Страница 81: ...size depends on the number of disk drives in the array RAID 60 Arrays Similar to a RAID 50 array see page 80 a RAID 60 array also known as dual drive failure protection is built from eight disk drive...

Страница 82: ...ty Disk drive usage read performance and write performance depend on the number of drives in the logical drive In general the more drives the better the performance RAID Level Redundancy Disk Drive Us...

Страница 83: ...dify Controller Settings 88 Formatting and Verifying Disk Drives 91 Locating Disk Drives 91 Identifying Disk Drives 92 Viewing the Event Log 92 The Adaptec RAID Configuration ARC utility is a BIOS bas...

Страница 84: ...system s configuration This is normal Navigating the ARC Utility All the tools within the ARC utility are menu based and instructions for completing tasks appear on screen Menus can be navigated usin...

Страница 85: ...array To make an array bootable 1 Select Manage Arrays from the main ACU menu 2 Select the array that you want to make bootable then press Ctrl B Note You cannot make an array bootable while it s buil...

Страница 86: ...ss Enter to accept the values Initializing Disk Drives If a disk drive appears grayed out unavailable for use in a new array it may need to be initialized To begin initializing a disk drive select Ini...

Страница 87: ...U window select Secure Erase 2 Select the disk drive being secure erased then press Ctrl Q The secure erase stops and the ACU returns to its main window Managing Global Hot Spares A hot spare is a dis...

Страница 88: ...cations Before you can enable MaxIQ caching on a logical device see page 86 you must assign at least one SSD to the MaxIQ pool Note Non Adaptec SSDs cannot be used for MaxIQ cache For more information...

Страница 89: ...oller General Controller Settings Note Default settings are shown in bold type Option Description Drive s Write Cache When set to Enable All write cache is enabled on all disk drives on the controller...

Страница 90: ...et to Fault Only the drive LEDs blink to indicate fault state only Default is Activity Fault Selectable Performance Mode When set to Dynamic performance criteria adjusts automatically based on control...

Страница 91: ...by blinking the LED To locate a disk drive 1 Start the ARC utility see page 84 2 Select the controller you want then press Enter 3 Select Disk Utilities 4 Select the disk drive you want then press En...

Страница 92: ...re information see Backplane Connections on page 71 Expanders The connections is determined by an expander Exp0 expander 0 is connected to phy0 phy 0 within a connector For more information see SAS Ex...

Страница 93: ...chapter describes the Array Configuration Utility ACU for DOS a text based utility that you can use to create configure and manage arrays A BIOS based ACU is also available See page 84 Note Adaptec r...

Страница 94: ...ler 2 Insert a bootable floppy disk and copy the acu exe file to it 3 Continue in one of two ways Work in the ACU using menus see the following section Run the ACU using scripts see page 95 Working in...

Страница 95: ...ll hot spares assigned to the RAID 10 For more information see Method Keyword on page 99 Switch Description P file Playback Mode The ACU reads the contents of the specified script file and creates arr...

Страница 96: ...placed in the same location as the ACU executable The ACU supports only a subset of available array types If it encounters an array it can t create a warning displays or is recorded in the log file i...

Страница 97: ...cript file is initialized which destroys any data on that disk drive Keyword Required Description Array Yes Indicates the start of an array definition block No default See page 97 Drives Yes Specifies...

Страница 98: ...the list to all arrays within the multilevel array InitializeAll Keyword If you want the ACU to initialize all drives connected to the controller and delete any existing arrays before any new arrays...

Страница 99: ...a by recreating the logical drive without the initialization step Omitting the initialization step reconstructs the logical drive metadata without modifying or destroying any other data on the disks F...

Страница 100: ...is used for this array if write caching is supported for the system Possible values are as follows Yes default Enable the write cache No Disable the write cache Setting an array s WriteCache keyword t...

Страница 101: ...found in system 8 Specified array size too small You specified an array size that is smaller than the minimum size allowed for this array 9 Specified array size too big You specified an array size th...

Страница 102: ...tspareDrives 0 3 0 End This sample script file creates a maximum size three disk drive RAID 5 Create a maximum size RAID 5 labeled MyData Array MyData Type RAID5 Size Maximum Use the maximum stripe si...

Страница 103: ...ased DOS utility that you can use to update save or verify the RAID controller s firmware BIOS and NVRAM Caution Although the AFU contains safeguards to prevent you from accidentally damaging your RAI...

Страница 104: ...y such as EMM386 SYS and DOS4GW Before You Begin 1 Obtain the firmware see the following section 2 Create firmware disks see page 105 There are two ways to run the AFU 1 Using the AFU menus see page 1...

Страница 105: ...le floppy disk enter the system setup utility and change the setting 2 Insert the firmware update disk created using the steps above containing AFU exe 3 At the DOS command prompt type AFU with no arg...

Страница 106: ...see page 106 and any switches you want Note To find a controller number type AFU LIST then press Enter The AFU processes the command prompts you to insert additional floppy disks as needed exits and...

Страница 107: ...ased on the RAID controller type In this example the AFU saves flash contents from RAID controller 0 to a UFI file in the current default drive and directory A AFU SAVE C 0 In this example the AFU sav...

Страница 108: ...ile Build 5748 Controller 0 Adaptec RAID 51645 ROM Checksum 797B VALID Build 5748 File Checksum 797B VALID Build 5748 Image Compares Correctly Version Displays version information about the flash comp...

Страница 109: ...you want 6 Update the flash using the instructions suitable for your requirements To update a single RAID controller AFU UPDATE C cont_number Where cont_number is the number of the RAID controller wh...

Страница 110: ...ptec RAID 5805 5805Z LED and I2C Connector Specification 116 Adaptec RAID 51245 LED and I2C Connector Specification 118 Adaptec RAID 51645 LED and I2C Connector Specification 120 Adaptec RAID 52445 LE...

Страница 111: ...equivalent Alarm Mating Cable Connector Molex 50 57 9002 or equivalent 2249100 R ASR 5085 512MB RoHS SGL J2 Pin Number Signal Description 22 55 2161 Pin Number 1 3 3V LED Anode 2 2 ACTIVITY CN0 LANE...

Страница 112: ...3V J14 Pin Number Signal Description 22 55 2161 Pin Number 1 3 3V LED Anode 2 2 STATUS CN0 LANE 0 LED Cathode 1 3 3 3V LED Anode 4 4 STATUS CN0 LANE 1 LED Cathode 3 5 3 3V LED Anode 6 6 STATUS CN0 LAN...

Страница 113: ...23 or equivalent Alarm Mating Cable Connector Molex 50 57 9002 or equivalent J12 Adaptec RAID 5405 5405Z I2C Board Connector Molex 22 43 6030 or equivalent 2258100 R ASR 5405 RoHS KIT 2258100JA R ASR...

Страница 114: ...ote For Adaptec RAID 5445 header J2 is a 16 pin connector pins 1 16 For Adaptec RAID 5445Z header J2 is an 8 pin connector pins 1 8 only J4 Pin Number Signal 3 I2C Clock 2 Ground 1 I2C Data J14 Pin Nu...

Страница 115: ...tus LED Board Connector Molex 10 89 7162 or equivalent Status LED Mating Cable Connector Molex 22 55 2161 or equivalent 5 3 3V LED Anode 6 6 ACTIVITY CN0 LANE 2 LED Cathode 5 7 3 3V LED Anode 8 8 ACTI...

Страница 116: ...ode 6 6 STATUS CN0 LANE 2 LED Cathode 5 7 3 3V LED Anode 8 8 STATUS CN0 LANE 3 LED Cathode 7 9 3 3V LED Anode 10 10 STATUS CN1 LANE 0 LED Cathode 9 11 3 3V LED Anode 12 12 STATUS CN1 LANE 1 LED Cathod...

Страница 117: ...30 or equivalent J4 Adaptec RAID 5805 5805Z I2C CN1 Board Connector Molex 22 43 6030 or equivalent I2C Mating Cable Connector Molex 22 43 3030 or equivalent 8 ACTIVITY CN0 LANE 3 LED Cathode 7 9 3 3V...

Страница 118: ...ock 2 Ground 1 I2C Data J14 Pin Number Signal Description 22 55 2161 Pin Number 1 3 3V LED Anode 2 2 STATUS CN0 LANE 0 LED Cathode 1 3 3 3V LED Anode 4 4 STATUS CN0 LANE 1 LED Cathode 3 5 3 3V LED Ano...

Страница 119: ...ACTIVITY CN0 LANE 0 LED Cathode 9 11 3 3V LED Anode 12 12 ACTIVITY CN0 LANE 1 LED Cathode 11 13 3 3V LED Anode 14 14 ACTIVITY CN0 LANE 2 LED Cathode 13 15 3 3V LED Anode 16 16 ACTIVITY CN0 LANE 3 LED...

Страница 120: ...c RAID 51645 Activity LED Header Connector for CN0 CN1 Molex 10 89 7162 or equivalent Activity LED Header Mating Cable Connector Molex 22 55 2161 or equivalent J3 J10 Pin Number Signal Description 2 A...

Страница 121: ...CN0 LANE 1 LED Cathode 11 13 3 3V LED Anode 14 14 ACTIVITY CN0 LANE 2 LED Cathode 13 15 3 3V LED Anode 16 16 ACTIVITY CN0 LANE 3 LED Cathode 15 J1 Pin Number Signal Description 22 55 2161 Pin Number 1...

Страница 122: ...CN1 Molex 10 89 7162 or equivalent Activity LED Header Mating Cable Connector Molex 22 55 2161 or equivalent J3 J10 Pin Number Signal Description 2 ACTIVITY LED Cathode 1 3 3V LED Anode J12 Pin Numbe...

Страница 123: ...2 LED Cathode 13 15 3 3V LED Anode 16 16 ACTIVITY CN0 LANE 3 LED Cathode 15 J1 Pin Number Signal Description 22 55 2161 Pin Number 1 3 3V LED Anode 2 2 ACTIVITY CN3 LANE 0 LED Cathode 1 3 3 3V LED An...

Страница 124: ...J25 J26 J27 J28 J29 J30 3 3 3V LED Anode 4 4 ACTIVITY CN4 LANE 1 LED Cathode 3 5 3 3V LED Anode 6 6 ACTIVITY CN4 LANE 2 LED Cathode 5 7 3 3V LED Anode 8 8 ACTIVITY CN4 LANE 3 LED Cathode 7 9 3 3V LED...

Страница 125: ...lent J2 Adaptec RAID 2405 Aggregate Activity LED Board Connector Molex 22 28 4023 or equivalent Aggregate LED Mating Cable Connector Molex 50 57 9002 or equivalent J1 2260300 R ASR 2045 RoHS SGL J1 Pi...

Страница 126: ...ED and I2C Connector Quick Reference 126 Adaptec RAID 2405 I2C Board Connector Molex 22 43 6030 or equivalent I2C Mating Cable Connector Molex 22 43 3030 or equivalent J4 J4 Pin Number Signal 3 I2C Cl...

Страница 127: ...le strap and ensure that it makes skin contact Connect the equipment end of the strap to an unpainted metal surface on the chassis If a wrist strap is not available ground yourself by touching the met...

Страница 128: ...H Technical Specifications In this appendix Environmental Specifications 129 DC Power Requirements 129 Current Requirements 129...

Страница 129: ...e Up to 3 000 meters Bus Type Description Requirements PCIe Ripple and noise 50 mV peak to peak max PCIe DC Voltage 3 3 V 9 12 V 8 Adaptec Model Typical Current Adaptec RAID 5085 0 45 A 3 3 VDC 1 0 A...

Страница 130: ...anager 60 creating arrays 46 installing 60 adapters See controllers advanced data protection 16 AFU 61 103 to 109 Alarm Control setting 90 ARCCONF 60 Array Background Consistency Check setting 89 90 A...

Страница 131: ...89 SAS Address setting 91 SAS cables 32 setting boot controller 44 specifications 128 standard features troubleshooting 63 updating firmware 104 upgrading firmware 17 copyback 16 CRC Checking setting...

Страница 132: ...nd OpenServer 51 driver and operating system 48 driver and UnixWare 52 driver and VMWare 53 driver and Windows 49 existing operating system 34 external devices 42 installation options 33 solid state d...

Страница 133: ...dress 70 SAS cards 68 SAS devices 68 SAS domain 72 terminology 68 transceivers 69 wide connectors 70 wide ports 70 SAS Address setting 91 SAS devices 68 SAS disk drive identifiers 71 scripts in ACU fo...

Страница 134: ...grading firmware 17 utilities Adaptec RAID Controller utility 61 AFU 61 ARCCONF 60 V verifying disk drives 91 VMWare driver installation 58 OS installation 53 W Windows driver installation 56 OS insta...

Страница 135: ...ilpitas Boulevard Milpitas CA 95035 USA 2009 Adaptec Inc All rights reserved Adaptec and the Adaptec logo are trademarks of Adaptec Inc which may be registered in some jurisdictions Part Number CDP 00...

Отзывы: