Adaptec 31205 - RAID Controller Скачать руководство пользователя страница 5

   - To use a VSS hardware provider to create snapshots (such as the 
     Adaptec VSS provider for external RAID storage), you must install 
     Microsoft hotfix 916048, as described in Microsoft KB article  
     915043. The hotfix is required for any VSS hardware provider,   
     not just the Adaptec VSS provider. You must install the hotfix   
     even if you intend to use the Adaptec VSS provider to create   
     snapshots from a 3rd-party backup application only.  
      
     If you will not be creating snapshots using a VSS hardware    
     provider, you do not need to apply the hotfix.  
 
     NOTE:  Adaptec has identified a conflict between the Microsoft  
            hotfix and the QLogic 4010 storport drivers for Windows.  
            After applying the hotfix, the storport driver for the  
            Qlogic 4010C does not reload after the system reboots.  
            As a result, you cannot use a VSS hardware provider and  
            a QLogic iSCSI adapter at same time. 
             
            The issue has been reported to both Microsoft and QLogic. 
            Be sure to check with your support representative to  
            determine if issue is resolved. 
             
   - You can only add a Management Service from an Adaptec Storage  
     Manager console (GUI) running on Windows or Linux. In addition, 
     the External RAID node won’t even appear in the GUI on operating   
     systems other than Windows and Linux. 
      
   - For proper operation of Adaptec Storage Manager and the 
     management service on Windows XP, you must unblock 'javaw'   
     in the Windows firewall: 
      
     1.  Unblock 'javaw' in the Windows firewall. 
      
     2.  Under Windows firewall -> Exceptions, click Add port. Enter   
         name. In the port field enter 8003. Select TCP. Then, click OK.           
          
     3.  Restart the Windows firewall. 
      
   - VLANs are not supported in this release. Do not attempt to set  
     the VLAN ID for iSCSI ports in the Adaptec Storage Manager  
     console (GUI) or CLI. 
 
-------------------------------------------------------------------- 
3. Adaptec Storage Manager General Cautions and Notes 
 
   3.1 General Cautions 
 
   - While building or clearing a pool, do not remove and  
     reinsert any drive from that pool. Doing so may cause  
     unpredictable results. 
      
   - While a drive is being cleared, do not try to include it in a 
     new pool. Doing so may cause unpredictable results. 
 
   - Do not move drives containing a pool or volume from one  
     controller to another while the power is on. Doing so could  
     cause the loss of the pool configuration or data, or both.  
     Instead, power off both affected controllers, move the drives,  
     and then restart. 
 
   - When using Adaptec Storage Manager and the CLI concurrently,  
     configuration changes may not appear in the Adaptec Storage  
     Manager console until you refresh the display (by pressing F5). 

Содержание 31205 - RAID Controller

Страница 1: ...ral Cautions 3 2 General Notes 4 Operating System Specific Issues and Notes 4 1 All 4 2 Windows All 4 3 Windows 2000 4 4 Windows for EM64T and AMD 64 4 5 Linux 4 6 NetWare 5 RAID Level Specific Notes...

Страница 2: ...indows XP Professional Microsoft Windows for EM64T and AMD 64 o Windows Server 2003 Enterprise Standard and Web Edition o Windows XP Professional Linux 32 Bit o Red Hat o Red Hat EL 3 0 AS ES WS o Red...

Страница 3: ...nstallation CD o compat libstdc 7 3 2 96 122 i386 rpm o compat libstdc devel 7 3 2 96 122 i386 rpm NOTE The version string in the file name may be different than above Be sure to check the version str...

Страница 4: ...to replicate the SMTP e mail notification list RaidJob ser to replicate the jobs in the Task Scheduler 6 Install Adaptec Storage Manager on the other servers 7 Copy the files from the diskette into th...

Страница 5: ...the External RAID node won t even appear in the GUI on operating systems other than Windows and Linux For proper operation of Adaptec Storage Manager and the management service on Windows XP you must...

Страница 6: ...0 bytes the file is copied to a new file with the extension OLD and the original that is the LOG file is deleted and recreated If a OLD file already exists the existing OLD file is destroyed The blink...

Страница 7: ...it within 3 seconds It has no affect on file I O or other system operations and can be ignored 4 3 Windows 2000 More event notifications are generated than pools degraded For example in a configuratio...

Страница 8: ...re To suppress these messages add the following line to your Xdefaults file stringConversionWarnings False On rare occasions the online help system may generate a Java exception This is due to a known...

Страница 9: ...ize one or more drives in a snapshot source pool the snapshot target cannot be deleted To avoid creating a snapshot drive that cannot be deleted you must delete the snapshot drive first before you ini...

Страница 10: ...n rare occasions Adaptec Storage Manager may report that there is insuffient space to create a mirror plex WORKAROUND Press F5 to refresh then try again A recurring job that creates and mounts a snaps...