background image

Fitting Instructions for Ritekey 30-01. Rev 3 June 2005.

3. To Change the Master Code

• Enter the default or old master code and wait for the LED to come on.
• Enter the default or old master code for a second time and wait for the green to come on.
• Press keys 00 and wait for the red LED
• Enter the new master code and the green LED will flash in standby.
• Write down the new master code and keep it in a safe place.  Do not use the master code as a user code.
• The green LED will flash in standby.

4. To Create/Change the User Code

• Enter the 4 or 5 digit master code and wait for the red LED to come on.
• Enter the master code for a second time and wait for the green LED to come on.
• Press any two keys i.e. 01 to 50 to store the User Code Position Number and wait for the red LED to come on.
• Enter the new User Code, which must consist of 4 digits for a 4 digit master code and 5 digits for a 5 digit master code.  

Regardless of the number of digits, do not use the master code as a user code.  Do not use the same User Code for other 
User Code Position Numbers.

• Write down the new 2 digit User Code Position Number and the new 4 or 5 digit User Code number.

5. Changing the Delay for the Back to Standby Mode

• Enter the Master Code and wait for the red LED to come on.
• Enter the Master Code for a second time and wait for the green LED to come on.
• Enter the code 66 and the green LED should be lit.
• Press any two keys from 01 to 99 for the new time delay (01 being 1 second and 99 being 99 seconds).
• The green LED will then flash in standby.

6. To Change the Duration of Door Latched Mode

• Enter the master code and wait for the red LED to light.
• Enter the master code for the second time and wait for the green LED to light.
• Press keys 71, and the green LED will light.
• Press any two keys from 01 to 99 for the new time delay in minutes (01 being 1 minute and 99 being 99 minutes).
• The green LED will then flash in standby.

7. To Change the Duration of Door Unlocked Mode

• Enter the master code and wait for the red LED to light.
• Enter the master code for the second time and wait for the green LED to light.
• Press keys 77, and the green LED will light.
• Press any two keys from 01 to 99 for the new time delay in seconds (01 being 1 second and 99 being 99 seconds).
• The green LED will then flash in standby.

8. To Delete all User Codes from Positions 01 to 50

• Enter the master code and wait for the red LED to light.
• Enter the master code for the second time and wait for the green LED to light.
• Press keys 88, and the red LED will light for approximately 3 seconds.
• The green LED will then flash in standby.

9. To Change the Duration the Exit Button Override Mode

• Enter the master code and wait for the red LED to light.
• Enter the master code for the second time and wait for the green LED to light.
• Press keys 99, and the green LED will light.
• Press any two keys from 01 to 99 for the new time delay in seconds (01 being 1 second and 99 being 99 seconds).
• The green LED will then flash in standby.

6

Содержание RiteKey 30-01

Страница 1: ...eKey 30 01 IP65 Rating Keypad Face Only Contents Installing Keypad and Backplate page 1 3 Wiring Details page 4 User Manual page 5 6 Adams Rite Europe Ltd Moreton Industrial Estate London Road Swanley Kent UK BR8 8TZ Tel 44 0 1322 668024 Fax 44 0 1322 660996 E mail info adamsrite co uk www adamsrite co uk ...

Страница 2: ...to brickwork use the rawl plugs provided and drill two 6mm diameter holes to suit Otherwise drill the two fixing holes 3mm in diameter to allow a 4mm button head screw to cut its own thread 3 Install the cable run to the power supply and the lock 4 Ensure the diameter of the cable is sufficient for the length of the run and the amperage draw of the lock so as to minimise line drop Alarm cable or b...

Страница 3: ...hich separates from the terminal pins by pulling on the terminal block As the terminal block is lifted away it will reveal the functions of the different pins written onto the PCB as shown in fig 4 Make the connections to the terminal block as per the diagram and refit the terminal block to the PCB Please take care to refit the block the correct way around with the cable entry pointing away from t...

Страница 4: ...ck plate Hook the keypad onto the back plate by the slot in the rear of the keypad located at the top of the aperture as per fig 4 Pivot the keypad so that it sits flat against the back plate and is in line with the tapped hole located in the underside of the flange of the back plate Tighten the Allen screw and complete the remaining tasks as described Fig 3 Inserting Keypad Cable into Back Plate ...

Страница 5: ...if Fail Safe 12V DC PSU Negative Connect to Negative Supply from Lock for both Fail Safe and Fail Secure 12V DC PSU Positive Link to Door Relay Common MOV LOCK PSU Wiring Diagram For Ritekey 30 01 12VDC Shown Specification Operating Voltage 12 to 18 Volts AC or DC Current Consumption standby mode approx 15ma Maximum Draw 130ma not including door lock Door Relay maximum rating 2 amps at the operati...

Страница 6: ...on Override Mode The period of time that can be set between 01 and 99 seconds for which the electrical locking hardware can be unlocked to allow exit from the building Setting Up 1 Factory Default Settings The Master Default Code is a 5 digit number and is factory set at 12345 The Duration of Door Unlocked Mode to unlock the electrical locking hardware is factory set at 10 seconds The Duration of ...

Страница 7: ...t Press any two keys from 01 to 99 for the new time delay 01 being 1 second and 99 being 99 seconds The green LED will then flash in standby 6 To Change the Duration of Door Latched Mode Enter the master code and wait for the red LED to light Enter the master code for the second time and wait for the green LED to light Press keys 71 and the green LED will light Press any two keys from 01 to 99 for...