background image

Fitting Instructions for Ritekey 30-01. Rev 3 June 2005.

Terminal block shown in position as shipped, note
its position with the cable entry pointing away
from the PCB.  (The wall of the keypad is 
particularly removed for clarity).

Fig.3 Position of Terminal Block

Fig.4 Diagram Showing PCB Connectio

ns

Remove the terminal block from the PCB, which separates from
the terminal pins by pulling on the terminal block.

As the terminal block is lifted away it will reveal the functions of
the different pins written onto the PCB as shown in fig. 4

Make the connections to the terminal block as per the diagram
and refit the terminal block to the PCB.  Please take care to refit
the block the correct way around with the cable entry pointing
away from the PCB as shown in diagram 3.

Fig 5. Connecting the Cable Run and 

Block to the Keypad

DOOR C 

EXIT B

RETURN

COM

N/O

N/C

POWER

AC/DC

11-16V

2

Содержание RiteKey 30-01

Страница 1: ...eKey 30 01 IP65 Rating Keypad Face Only Contents Installing Keypad and Backplate page 1 3 Wiring Details page 4 User Manual page 5 6 Adams Rite Europe Ltd Moreton Industrial Estate London Road Swanley Kent UK BR8 8TZ Tel 44 0 1322 668024 Fax 44 0 1322 660996 E mail info adamsrite co uk www adamsrite co uk ...

Страница 2: ...to brickwork use the rawl plugs provided and drill two 6mm diameter holes to suit Otherwise drill the two fixing holes 3mm in diameter to allow a 4mm button head screw to cut its own thread 3 Install the cable run to the power supply and the lock 4 Ensure the diameter of the cable is sufficient for the length of the run and the amperage draw of the lock so as to minimise line drop Alarm cable or b...

Страница 3: ...hich separates from the terminal pins by pulling on the terminal block As the terminal block is lifted away it will reveal the functions of the different pins written onto the PCB as shown in fig 4 Make the connections to the terminal block as per the diagram and refit the terminal block to the PCB Please take care to refit the block the correct way around with the cable entry pointing away from t...

Страница 4: ...ck plate Hook the keypad onto the back plate by the slot in the rear of the keypad located at the top of the aperture as per fig 4 Pivot the keypad so that it sits flat against the back plate and is in line with the tapped hole located in the underside of the flange of the back plate Tighten the Allen screw and complete the remaining tasks as described Fig 3 Inserting Keypad Cable into Back Plate ...

Страница 5: ...if Fail Safe 12V DC PSU Negative Connect to Negative Supply from Lock for both Fail Safe and Fail Secure 12V DC PSU Positive Link to Door Relay Common MOV LOCK PSU Wiring Diagram For Ritekey 30 01 12VDC Shown Specification Operating Voltage 12 to 18 Volts AC or DC Current Consumption standby mode approx 15ma Maximum Draw 130ma not including door lock Door Relay maximum rating 2 amps at the operati...

Страница 6: ...on Override Mode The period of time that can be set between 01 and 99 seconds for which the electrical locking hardware can be unlocked to allow exit from the building Setting Up 1 Factory Default Settings The Master Default Code is a 5 digit number and is factory set at 12345 The Duration of Door Unlocked Mode to unlock the electrical locking hardware is factory set at 10 seconds The Duration of ...

Страница 7: ...t Press any two keys from 01 to 99 for the new time delay 01 being 1 second and 99 being 99 seconds The green LED will then flash in standby 6 To Change the Duration of Door Latched Mode Enter the master code and wait for the red LED to light Enter the master code for the second time and wait for the green LED to light Press keys 71 and the green LED will light Press any two keys from 01 to 99 for...

Отзывы: