background image

©Adam Equipment Co. 2019 

11 

To  disable  the  Check-Weighing  function  enter  zero  into  both  limits  by  pressing  the 

[Func/Set]

 key when the current limits values are displayed during the setting procedure, 

then pressing 

[Tare/

]

 to store the zero values. 

The values set for the check-weighing will remain in memory when the weighing units or 
the function changes to parts counting but will not be active.  The will become active again 
when the weighing unit or parts counting that was active at the time the limits were set is 
reactivated.  

6.8 

ACCUMULATED

 

TOTAL 

The scale can be set to accumulate manually by pressing the 

[CHK/  Print]

key  or  automatically  when  a  weight  is  removed  from  the  scale.    The
accumulation  function  is  available  when  weighing  or  when  counting  parts.
However  the  memory  is  cleared  if  the  weighing  units  or  functions  are
changed.

When  the  weight  (or  count)  displayed  is  stored  in  memory  the  display  will
show “ACC 1” and then the total in memory for 2 seconds before returning to
weighing.  The RS-232 interface will output to a printer or PC.

Remove  the  weight,  allowing  the  scale  to  return  to  zero  and  put  a  second
weight on.  When this value is stored, the display will show “ACC   2”, then
the new total and finally the value of the second weight. Repeat as necessary
to add all the values needed to the memory.

To  view  the  total  in  memory  press  the 

[CHK/Print]

  key  when  there  is  no

weight  on  the  scale.    The  display  will  show  the  number  of  entries  and  the
total.

To clear the memory (set the value to zero) press the 

[Power/ST]

 key during

the time the totals are being displayed, “Clear” will flash on the display for 2-3
seconds and then return to the usual weighing display.

6.9 

PERCENT WEIGHING  

The scale can be set to perform percent weighing.  

The scale will use a mass on the platform as the 100% reference weight. 

Press the 

[Func/Set]

 key to select the weighing mode.

Using  the  directional  buttons 

  or 

,  scroll  through  to  the  parts  counting

mode, 

“Percent”

 will be shown on the display. Press 

[Tare/

to confirm. 

Once  in  percent  weighing  mode  the  “%”  indicator  will  appear  on  the  right-
hand side of the display.

Содержание AGF 600aM

Страница 1: ...Adam Equipment AGF Floor Scale Software rev V 1 00 above Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Страница 2: ...Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place...

Страница 3: ...HECK WEIGHING 9 6 7 1 Relay outputs and checkweighing 9 6 8 ACCUMULATED TOTAL 11 6 10 ANIMAL Dynamic WEIGHING 12 6 10 1 Animal weighing procedure 13 6 11 ANIMAL 2 DYNAMIC 2 WEIGHING 13 6 11 1 Animal 2...

Страница 4: ...ighing semi automatic tare and an accumulation facility that allows individual weights or counts to be stored and the total recalled The scales have a bi directional RS 232 interface for communicating...

Страница 5: ...ity 175lb 80kg 350lb 160kg 660lb 300kg 1320lb 600kg Readability 0 005lb 2g 0 01lb 5g 0 02lb 10g 0 05lb 20g Resolution 0 005lb 2g 0 01lb 5g 0 02lb 10g 0 05lb 20g Repeatability 0 005lb 2g 0 01lb 5g 0 02...

Страница 6: ...n the backlight is used Interface RS 232 bi directional Interface Display 6 digits 40mm digit height LCD digital display with backlight Balance Housing Indicator IP 67 rated Stainless Steel Scale Grad...

Страница 7: ...es Avoid unstable power sources Do not use near large users of electricity such as welding equipment or large motors Do not place near vibrating machinery Avoid air movement such as from fans or openi...

Страница 8: ...n for scrolling Also used for incrementing the active digit when setting a value for Parameters Disp Mode Selects the weighing unit to be displayed from those which are enabled See parameter rS1 in se...

Страница 9: ...ery 6 0 OPERATION 6 1 ZEROING THE DISPLAY You can press the 0 Esc key at any time to set the zero point This will usually be necessary when the platform is empty You can only zero off a weight up to a...

Страница 10: ...Again only the weight that is added after taring will be displayed When the container is removed a negative value will be shown If the scale was tared just before removing the container this value is...

Страница 11: ...known number of samples in the container if used The number should match the options for parts counting i e 10 20 50 100 or 200 pieces Press the Func Set key to select the weighing mode Using the dire...

Страница 12: ...o move to the next digit Press Tare to confirm Once confirmed Lo will appear on the display followed by a value on the display with a flashing digit To set the low limit follow the same process as bef...

Страница 13: ...n The beeper will be on when the weight is less than the High Limit Above the High Limit the beeper will be off CHK bP Out When set to bP OtL the indicator alarm will turn on below the high limit with...

Страница 14: ...memory for 2 seconds before returning to weighing The RS 232 interface will output to a printer or PC Remove the weight allowing the scale to return to zero and put a second weight on When this value...

Страница 15: ...eight of 100 on platform Press the Disp Mode key Display will show 100 The weight entered must be greater than 50 scale divisions Press the Func Set key to select a new weighing mode NOTE The display...

Страница 16: ...termined The time it takes for the stable value will depend upon the setting of the filter parameter in the first step When a stable reading is found the display will show this value and the display w...

Страница 17: ...kets alternatively a long press on the Tare key will retain the container or blanket value as NET Place the animals or sample to be weighed on the platform Press Tare key to start to the measurement T...

Страница 18: ...e top right corner of the display Once the weight has stabilised the weight value will remain on the display until either more weight is added onto the weighing pan or the weighing mode is changed If...

Страница 19: ...be changed when the display shows mmddyy ddmmyy or yymmdd by pressing the Pcs key then enter the date Enter the date format and then the numeric value manually mm dd yy bL Backlight set to always on...

Страница 20: ...directional keys Press Tare to enter the rs 1 or rs 2 parameters when appearing on the display Rs 1 will provide access to Print PC and Cmd settings Rs 2 includes PC and Cmd only Press Tare to confirm...

Страница 21: ...r 7 Lfcr 8 Lfcr 9 Lfcr 10 Lfcr 1 Lfcr Scale will perform the following depending on the Accumulation and Print Settings ACCUMULATION SETTINGS PRINT SETTINGS AC on AC Off AUto Accumulate and print auto...

Страница 22: ...The battery should be charged when only the battery outline is on Once the bars have been turned off the scale will still operate for a short time after which it will automatically switch off to prot...

Страница 23: ...eived Data 3 Pin TXD Transmitted Data As viewed from the back of the indicator The scale can be set to print text in English French German Spanish Italian or Portuguese See the RS 232 parameters secti...

Страница 24: ...lf Peak Holt Wt 1 500 Kg cr lf cr lf cr lf cr lf cr lf cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf Hold Wt 1 000 Kg cr lf cr lf cr lf...

Страница 25: ...00 cr lf Unit wt 1 0234g Pieces 1000 PCS cr lf cr lf cr lf cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf Net Wt 1 500 Kg cr lf Ref Wt 10...

Страница 26: ...Piezas Pezzi Pe as High Limit set by user High Limit Lim Sup rieure Obergrenze Lim Superior Lim Superiore Lim Superior Low Limit set by user Low Limit Lim Inf rieure Untergrenze Lim Inferior Lim Infe...

Страница 27: ...enter the password use the directional buttons or to scroll through numbers 1 9 Use the directional key to move to the next digit Entering the correct password 1000 will bring you to the user setup me...

Страница 28: ...em persists contact your dealer or Adam Equipment for assistance Err 6 A D out of range The values from the A D converter are outside the normal range Remove the weight from the scale if overloaded Ma...

Страница 29: ...ady A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods B Details of the unit purchased This part of information should always be ava...

Страница 30: ...aulty installation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual This product may include a rechargeable batter...

Страница 31: ...rcial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio c...

Страница 32: ...bed as follows Analytical and Precision Laboratory Balances Compact and Portable Balances High Capacity Balances Moisture analysers balances Mechanical Scales Counting Scales Digital Weighing Check we...

Отзывы: