© Adam Equipment Company 2012

 

 

 

 

    

 

4.1

 

REAR

 

PANEL 

The  rear  panel  has  a  connector  input  for  the  external  power  adaptor  (12  volts  DC 

@800ma). 

 

4.2

 

INTERNAL

 

RECHARGEABLE

 

BATTERY 

The  scale  can  be  operated  from  the  internal  rechargeable  battery  or  using  an 

adapter. The battery life is approximately 24 hours with the backlight off. Depending 

on the usage of the backlight the lifetime of the battery will reduce. 

The display will show an indication when the battery needs to be charged. To charge 

the  battery  plug  the  adapter  into  the  POWER  input  socket  in  the  rear  panel  and 

connect it to the mains power supply. The charging indicator in the lower left corner 

of the LCD will be on to show it is charging and will turn green when the battery is 

fully charged. 

KEYS 

PRIMARY FUNCTION 

SECONDARY FUNCTION 

 

To turn the scale On or Off.   

 

 

To clear the readings on the display 
ready for the next weighing 

 

 

To change the displayed height 
reading between cm, feet or feet and 
inches     

To save and escape back to the 
parameter settings 

 

To send a command to print the 
current displayed readings  

To change the setting when in a USER 
parameter 

 

To change the displayed weight 
reading between Kg, Lb’s or Lb’s and 
Ounces 

To change the USER parameter  

 

To Zero the scale before weighing  
To Tare any item to obtain net weight 

To enter the selected setting  when in a 
USER parameter  

 

All manuals and user guides at all-guides.com

all-guides.com

Содержание MUW 300L

Страница 1: ...1 Adam Equipment Company 2012 Adam Equipment MUW HEALTH AND FITNESS SCALE USER MANUAL P N 7 00 6 6 0229 Revision A July 2012 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...TS 9 5 7 CLEARING A PREVIOUS RESULT 9 6 0 PARAMETERS 10 6 1 SETTING THE BACKLIGHT OPERATION F1 EL 10 6 2 SETTING AUTO OFF F2 OFF 11 6 3 SETTING THE PRINTING CONTROLS F3 SEr 11 6 4 PRINTING DETAIL CONT...

Страница 3: ...nstructions as below 1 Remove the base and pillar sections from the packaging 2 Lift the lower pillar section and place it with the screw holes at the rear onto the back of the base allowing for the c...

Страница 4: ...Do not use near large users of electricity such as welding equipment or large motors Do not let the balance battery go flat If you are not using it for a long time you should charge the battery perio...

Страница 5: ...D DISPLAY FUNCTION The keypad and display have a number of features as shown and explained below Charging LED Battery Symbol Zero Indicator Stable Indicator Tare Symbol Ultrasonic Sensor Symbol All ma...

Страница 6: ...rging indicator in the lower left corner of the LCD will be on to show it is charging and will turn green when the battery is fully charged KEYS PRIMARY FUNCTION SECONDARY FUNCTION To turn the scale O...

Страница 7: ...e parameters section 6 0 5 2 ZEROING You can press the Zero key to set a new zero point and show a zero reading This may be necessary if the weight reading is not indicating zero with nothing on the p...

Страница 8: ...nified by the symbol in the upper right part of the display and start to determine the height When a stable reading of weight is obtained the three readings will be displayed The results will remain o...

Страница 9: ...rint and Clear keys to move the flashing digit and the kg lb and cm ft keys to enter the Id number you require and press Zero to save The display will now show the Patients Id screen use the keys as a...

Страница 10: ...T T T See section 6 7 Setting the date and time F8 F8 F8 F8 SET SET SET SET UP UP UP UP See section 6 8 Set up parameters F9 F9 F9 F9 TE TE TE TECH CH CH CH Service only 6 1 SETTING THE BACKLIGHT OPER...

Страница 11: ...PRINTING CONTROLS F F F F3 3 3 3 SE SE SE SER R R R The MUW can be set to automatically print AUTO or print on demand PrN by pressing the Print button The data transmission speed Bps of the MUW must...

Страница 12: ...s can all be enabled or disabled to suit the information you need to see 1 Switch on the scale then press the kg lb key during the self checking test of the display 2 The display will show the first f...

Страница 13: ...plete the display will show AdJUST XX If after calibration the height sensor is not measuring correctly press Print or Clear at point 3 to change XX A lower number will decrease the height measurement...

Страница 14: ...her the Print or Clear key to move the flashing digit to the left or right 8 Press Zero to save cm ft to exit then kg lb to select the next parameter 6 8 SET UP F8 F8 F8 F8 SET SET SET SET UP UP UP UP...

Страница 15: ...w kg or lb press Print to select the unit of weight being used for the calibration and then Zero to confirm 3 The display will show CAL XX XX being the last calibration weight to be used 4 Press the P...

Страница 16: ...be sent in upper case letters i e T not t Z cr lf Will Zero the scale performs the same functions as pressing the Zero key P cr lf Will send a Print command to a PC or Printer Performs the same funct...

Страница 17: ...too high Err L Calibration weight value used too low Weight on top pan exceeds 300kg 660Lbs 10 0 TECHNICAL SPECIFICATIONS Model MUW 300L Maximum Capacity 300kg 660Lbs Readability 0 05kg 0 1Lbs Repeat...

Страница 18: ...orrect documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accid...

Страница 19: ...likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure...

Страница 20: ...s Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of this public...

Отзывы: