background image

 

 

 

 

 

 

 

11

 

© Adam Equipment Company 2012

 

 

 

6.2 

SETTING

 

AUTO

 

OFF

 

F2

F2

F2

F2

    

OFF

OFF

OFF

OFF

 

An automatic power down time can be set so that the MUW turns off after a period 

where no activity is detected. This preserves the life time of the battery when used 

in this mode. 

Settings are OFF, 5, 10, 20, and 30 minutes. 

1)  Switch on the scale then press the 

[kg/lb] 

key during the self-checking test of 

the display. 

2)  The display will show the first function 

F1

F1

F1

F1

    

EL.

EL.

EL.

EL.

  

3)  Press the 

[kg/lb]

 key to select 

F2

F2

F2

F2

    

OFF

OFF

OFF

OFF

    

  

and then 

[Zero] 

to enter and

 

show the 

current setting, default is 

10. 

4)

 

Press the 

[Print]

 key to change the setting for the backlight and press 

[Zero]

 

to save, then 

[kg/lb]

 to select the next parameter. 

6.3 

SETTING

 

THE

 

PRINTING

 

CONTROLS

 

FFFF3

3

3

3

    

SE

SE

SE

SE

R

R

R

R

 

The MUW  can be set to  automatically print “AUTO”,  or print on demand “PrN” by 

pressing the 

[Print]

 button. 

The data transmission speed “Bps” of the MUW must match that of the Printer or 

other device being used to collect data information successfully. 

The printing control and speed can be selected as follows. 

1)  Switch on the scale then press the 

[kg/lb] 

key during the self-checking test of 

the display. 

2)  The display will show the first function 

F1

F1

F1

F1

    

EL.

EL.

EL.

EL.

  

3)  Press  the 

[kg/lb] 

key  to select 

FFFF3

3

3

3

    

S

S

S

S

ER

ER

ER

ER

 

and  then 

[Zero] 

to  enter  and  show  the 

current printing control setting “UArt”. 

4)  Either printing on demand (PrN), pressing the 

[Print]

 key following a weighing, 

or  printing  automatically  (AUTO),  automatically  prints  out  when  a  stable 

reading and BMI calculation is displayed can be selected. 

All manuals and user guides at all-guides.com

all-guides.com

Содержание MUW 300L

Страница 1: ...1 Adam Equipment Company 2012 Adam Equipment MUW HEALTH AND FITNESS SCALE USER MANUAL P N 7 00 6 6 0229 Revision A July 2012 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...TS 9 5 7 CLEARING A PREVIOUS RESULT 9 6 0 PARAMETERS 10 6 1 SETTING THE BACKLIGHT OPERATION F1 EL 10 6 2 SETTING AUTO OFF F2 OFF 11 6 3 SETTING THE PRINTING CONTROLS F3 SEr 11 6 4 PRINTING DETAIL CONT...

Страница 3: ...nstructions as below 1 Remove the base and pillar sections from the packaging 2 Lift the lower pillar section and place it with the screw holes at the rear onto the back of the base allowing for the c...

Страница 4: ...Do not use near large users of electricity such as welding equipment or large motors Do not let the balance battery go flat If you are not using it for a long time you should charge the battery perio...

Страница 5: ...D DISPLAY FUNCTION The keypad and display have a number of features as shown and explained below Charging LED Battery Symbol Zero Indicator Stable Indicator Tare Symbol Ultrasonic Sensor Symbol All ma...

Страница 6: ...rging indicator in the lower left corner of the LCD will be on to show it is charging and will turn green when the battery is fully charged KEYS PRIMARY FUNCTION SECONDARY FUNCTION To turn the scale O...

Страница 7: ...e parameters section 6 0 5 2 ZEROING You can press the Zero key to set a new zero point and show a zero reading This may be necessary if the weight reading is not indicating zero with nothing on the p...

Страница 8: ...nified by the symbol in the upper right part of the display and start to determine the height When a stable reading of weight is obtained the three readings will be displayed The results will remain o...

Страница 9: ...rint and Clear keys to move the flashing digit and the kg lb and cm ft keys to enter the Id number you require and press Zero to save The display will now show the Patients Id screen use the keys as a...

Страница 10: ...T T T See section 6 7 Setting the date and time F8 F8 F8 F8 SET SET SET SET UP UP UP UP See section 6 8 Set up parameters F9 F9 F9 F9 TE TE TE TECH CH CH CH Service only 6 1 SETTING THE BACKLIGHT OPER...

Страница 11: ...PRINTING CONTROLS F F F F3 3 3 3 SE SE SE SER R R R The MUW can be set to automatically print AUTO or print on demand PrN by pressing the Print button The data transmission speed Bps of the MUW must...

Страница 12: ...s can all be enabled or disabled to suit the information you need to see 1 Switch on the scale then press the kg lb key during the self checking test of the display 2 The display will show the first f...

Страница 13: ...plete the display will show AdJUST XX If after calibration the height sensor is not measuring correctly press Print or Clear at point 3 to change XX A lower number will decrease the height measurement...

Страница 14: ...her the Print or Clear key to move the flashing digit to the left or right 8 Press Zero to save cm ft to exit then kg lb to select the next parameter 6 8 SET UP F8 F8 F8 F8 SET SET SET SET UP UP UP UP...

Страница 15: ...w kg or lb press Print to select the unit of weight being used for the calibration and then Zero to confirm 3 The display will show CAL XX XX being the last calibration weight to be used 4 Press the P...

Страница 16: ...be sent in upper case letters i e T not t Z cr lf Will Zero the scale performs the same functions as pressing the Zero key P cr lf Will send a Print command to a PC or Printer Performs the same funct...

Страница 17: ...too high Err L Calibration weight value used too low Weight on top pan exceeds 300kg 660Lbs 10 0 TECHNICAL SPECIFICATIONS Model MUW 300L Maximum Capacity 300kg 660Lbs Readability 0 05kg 0 1Lbs Repeat...

Страница 18: ...orrect documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accid...

Страница 19: ...likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure...

Страница 20: ...s Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of this public...

Отзывы: