![Adam Equipment GBC 130a Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/adam-equipment/gbc-130a/gbc-130a_user-manual_2846098031.webp)
© Adam Equipment Company 2011
12.1.1
F1 ‐CALIBRATION
To enter the calibration parameter, press the
[Tare]
key when
“F1” “CAL”
is displayed.
The scale should be calibrated using a mass of approximately 2/3Maximum to
Maximum. If the scale has been calibrated previously the value will be stored. Details
of calibration are given is section 8.0 .
12.1.2
F2 –PIN
To enter this parameter, press the
[Tare]
key when
“F2” “Pin”
is shown.
The
“Weight”
display will show
“Pin 1”
Enter the new password. The
“Unit Weight”
display will show dashes.
Press
[Tare]
.
The
“Weight”
display will change to
“Pin 2 “
, Enter the password again
and press
[Tare]
.
The display will show
“donE”
indicating the new password has been
accepted and will return to the menu.
“F3” “Unit”
is shown.
Record the new password in a secured place.
Press
[Zero]
to return to weighing.
12.1.3
F3 –Unit
To enter this parameter, press the
[Tare]
key when
“F3” “unit”
is shown.
This parameter allows the user to enable or disable the weighing units
available in his scales.
To enter this parameter, press the
[Tare]
key when
“F3” “Unit”
is shown.
The display will show the first available weighing unit and if it is On or
Off.
Press the
[U.Wt./Units]
key to change the value. Press
[Tare]
to accept
the displayed setting and go to the next unit.
Press the
[Zero]
key to return to the menus. Press the
[Zero]
key again
to return to normal weighing.