P a g e                  

© Adam Equipment Company 2013

 

3.2 

LOCATING

 

AND

 

PROTECTING

 

YOUR

 

SCALE 

 
In  order  to  keep  you  scale  functioning  at  its  best  we  suggest  that  you  do  the 

following:  

 

Avoid  extremes  of  temperature.  Do  not  place  in 
direct sunlight or near air conditioning vents. 

 

Make sure the scale is located on a strong table and 
free from vibration.  

 

Avoid unstable power sources. Do not use near large 
users  of  electricity  such  as  welding  equipment  or 
large motors. Do not mix batteries and use only the 
factory  approved  power  adapter  supplied  with  the 
machine. Do not use batteries and the AC adapter at 
the same time.  

 

Keep free from vibration. Do not place near heavy or 
vibrating machinery. 

 

Avoid high humidity that might cause condensation. 
Keep  away  from  direct  contact  with  water.  Do  not 
spray or immerse the scales in water. 

 

Do  not  place  near  open  windows,  air-conditioning 
vents  or  fans  that  may  cause  a  draft  and  unstable 
readings.  

 

Keep  the  scales  clean.  Do  not  stack  material  on  the 
scale / balance when it is not in use. 

 

Содержание DCT 2000

Страница 1: ...Adam Equipment Company 2013 Adam Equipment DUNE DCT SERIES P N 9384 Revision B2 June 2013...

Страница 2: ...am Equipment Company 2013 Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and pl...

Страница 3: ...FF 5 6 0 CALIBRATION 5 7 0 TROUBLE SHOOTING 6 7 1 ERROR MESSAGES 6 7 2 REPLACEMENT PARTS AND ACCESSORIES 6 8 0 SPECIFICATIONS 7 9 0 WARRANTY INFORMATION 8 2 0 INTRODUCTION Thank you for purchasing the...

Страница 4: ...he packaging Take care not to apply pressure to the top of the scale 2 Connect the power adapter to the socket on the back of the machine Installing Batteries Remove the battery compartment cover and...

Страница 5: ...ity such as welding equipment or large motors Do not mix batteries and use only the factory approved power adapter supplied with the machine Do not use batteries and the AC adapter at the same time Ke...

Страница 6: ...the maximum capacity of the scale This may be necessary if the weight is not reading zero with nothing on the platform The zero indicators will light up 0 If you are using a container to weigh then yo...

Страница 7: ...f the cal mass is not displayed then the machine is not stable or is not within a zero range Turn off the unit and try zeroing the display before trying another calibration 5 Place the appropriate cal...

Страница 8: ...the pan when turning on the unit Calibrate the machine Possible damage to the internal weighing cell UnSt Unstable Make sure the balance is on a flat surface and away from vibration Possible damage t...

Страница 9: ...lisation Time 2 seconds Operating Temperature 10 C to 40 C 14 F to 104 F Power Supply 12VAC 150mA adapter or 6x AA batteries Calibration Push button calibration using external mass Calibration Mass 20...

Страница 10: ...ginal packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performa...

Страница 11: ...a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with thi...

Страница 12: ...Health and Fitness Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co All rights reserved N...

Отзывы: