background image

© Adam Equipment Company 2020

 

Adam Equipment 

Cruiser (CKT & CKT‐M) 

SERIES  

Adam Equipment strives to be more environmentally focused and uses recycled materials and environmentally 

friendly packaging where possible. As part of this initiative we have developed a short form manual that uses 
less paper and ink to describe the main functions of your new Adam scale. A complete version is available at 
www.adamequipment.com. Thank you for your support of Adam Equipment and we hope that you enjoy your 
new scale.  

Содержание CKT 16

Страница 1: ...ials and environmentally friendly packaging where possible As part of this initiative we have developed a short form manual that uses less paper and ink to describe the main functions of your new Adam...

Страница 2: ...am Equipment Company 2020 Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and pl...

Страница 3: ...SCALE 6 4 2 SCALE COMPONENTS 7 5 0 REPLACING THE LOAD CELL 8 6 0 REPLACING THE DISPLAY 8 6 1 MODULE OPTION COVERS BOARDS 9 7 0 REPLACING THE PCB 9 8 0 CALIBRATION LINEARITY SETTINGS 10 9 0 FACTORY PA...

Страница 4: ...gram or kilogram weighing units The scales have stainless steel weighing platforms on an ABS base assembly All scales are supplied with an RS 232 bi directional interface and real time clock The scale...

Страница 5: ...g Readability 0 1 g 0 1 g 0 2 g 0 5 g 1 g 2 g Repeatability S D 0 2 g 0 2 g 0 4 g 1 g 2 g 42 g Linearity 0 3 g 0 3 g 0 6 g 1 5 g 3 g 6 g CKT UH Series CKT 8UH CKT 16UH CKT 32UH CKT 48UH Kilograms Maxi...

Страница 6: ...D 0 02 oz 0 02 oz 0 02 oz 0 02 oz Linearity 0 06 oz 0 06 oz 0 06 oz 0 06 oz Tare range 16 _16 00 35 _16 0 70 _16 0 100 _16 0 OTHER SPECIFICATIONS Units of measure CKT Series kg g CKTa Series kg g lb o...

Страница 7: ...g Scales Functions Weighing Parts counting weighing Check weighing Check counting Accumulation of weights Date Time Real Time Clock RTC To print date and time information battery backed CKT 4M CKT 8M...

Страница 8: ...7 digits LCD digital display with symbols for units Scale Housing ABS Plastic Stainless Steel platform Pan Size 225 x 275 mm 8 9 x 10 8 Overall Dimensions wxdxh 315 x 355 x 110 mm 12 4 x 14 x 4 3 Net...

Страница 9: ...nector located on the base to the left of the scale 4 Plug the power cable into the mains 5 Press the power button located on scale keypad 6 The scale will then display the software revision and run a...

Страница 10: ...requires verification once opened 4 2 SCALE COMPONENTS 1 PCB 2 Keypad 3 Display 4 Spirit level 5 Load cell metal frame upper supporter 6 Load cell 7 Load cell metal frame lower supporter 8 Power cable...

Страница 11: ...he screw positions line up Screw in the 2 central screw points to hold the load cell in place then carefully screw in the 4 exterior screw points Once secure place the scale s exterior casing back ont...

Страница 12: ...w the plastic cover for the charging board and USB components located beneath the scale Remove the USB and charging component On the inside of the scale disconnect the battery display and power connec...

Страница 13: ...Entering the correct password will bring you to the setup menu Once in the setting menu use the directional keys 1 and 6 to scroll through the menu until L Cal appears on the display and press the Tar...

Страница 14: ...ider variety of settings and options such as language currency decimal and linear calibration settings The display will show the first parameter ADCnt To scroll through other parameters press the nume...

Страница 15: ...te between the options and press Tare to select 9 6 G1 and G2 These options are related to specific gravity parameters of the scale G1 is the gravitational acceleration at place of manufacture G2 is g...

Страница 16: ...press Tare to select Note Trade approved machines require this to be set in accordance with specific rules 9 10 AUTO ZERO TRACKING The auto zero function calculates the limits at which the scale can...

Страница 17: ...press Tare to select 9 13 DUAL The dual parameter concerns the scale s dual weighing interval and range settings To enter this parameter press the Tare key when Dual is shown Use the numeric 1 or 6 ke...

Страница 18: ...s of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a print out in yo...

Страница 19: ...ce faulty installation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual This product may include a rechargeable ba...

Страница 20: ...generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this...

Страница 21: ...rmany Phone 49 0 4340 40300 0 Fax 49 0 4340 40300 20 e mail vertrieb aeadam de Adam Equipment S A Pty Ltd 7 Megawatt Road Spartan EXT 22 Kempton Park Johannesburg Republic of South Africa Phone 27 0 1...

Страница 22: ...Adam Equipment Company 2020 19...