background image

 

 

© Adam Equipment Company 2007 

 

7.0  BATTERY  

 
 

  The  scales  can  be  operated  from  the  battery,  if  desired.  The 

battery life is approximately 90 hours. 

 
 

  When the battery needs charging a symbol on the display will turn 

on.  The  battery  should  be  charged  when  the  symbol  is  on.  The 
scale  will  still  operate  for  about  10  hours  after  which  it  will 
automatically switch off to protect the battery. 

 
 

  To  charge  the  battery,  simply  plug  into  the  mains  power  supply. 

The scale does not need to be turned on. 

 
 

  The battery should be charged for 12 hours for full capacity. 

 
 

  To the left of the display is a LED to indicate the status of battery 

charging.    When  the  scale  is  plugged  into  the  mains  power  the 
internal battery will be charged.  If the LED is green the battery is 
being  charged.    If  it  is  red  it  is  nearly  discharged  and  yellow 
indicates  the  battery  is  increasing  the  charge  level.    Continue  to 
charge overnight for a complete re-charge. 

 
 

8.0  BACKLIGHT 

 
The backlight for the LCD can be set by the user to always off, always on or 
automatic (on only when the scale is in use or a key is pressed). See setting 
of the parameter “

S2  bL

” in section 13.3. 

 

9.0  AUTO POWER OFF 

 
The auto power off can be set by the user to disable the feature or to a pre-
set  time  interval.  See  setting  of  the  parameter  “

S3    AoF

  “  in  section  13.3.

BALANCES.COM

Содержание CBK series

Страница 1: ...Adam Equipment Company 2007 Adam Equipment CBK SERIES P N 8509 Revision A7 August 2007 Software Rev 4 28 above 4 25H above for CBK 8H 16aH BALANCES COM...

Страница 2: ...Adam Equipment Company 2007 BALANCES COM...

Страница 3: ...10 5 1 Setting up check weighing while weighing 14 10 5 2 Setting up check weighing while parts counting or weighing 14 10 6 LIMITS STORING AND RECALLING 15 10 7 PERCENT WEIGHING 16 10 8 ACCUMULATED...

Страница 4: ...eight is below the low limit between the limits or above the high limit next to the display These can work in conjunction with an audible alarm for check weighing as well as LCD showing LO OK and HI A...

Страница 5: ...0 001 lb 0 002 lb 0 005 lb Linearity 0 0004 lb 0 0004 lb 0 001 lb 0 002 lb 0 004 lb 0 01 lb Ounces Maximum Capacity 128 oz 256 oz 256 oz 560 oz 1120 oz 1600 oz Readability 0 005 oz 0 005 oz 0 01 oz 0...

Страница 6: ...units Scale Housing ABS Plastic Stainless Steel platform Pan Size 225 x 275 mm 8 9 x 10 8 Overall Dimensions wxdxh 315 x 355 x 110 mm 12 4 x 14 x 4 3 Net Weight 4 1 kg 9 lb Applications Weighing Scale...

Страница 7: ...Avoid unstable power sources Do not use near large users of electricity such as welding equipment or large motors Do not place near vibrating machinery Avoid high humidity that might cause condensati...

Страница 8: ...bubble in the spirit level is in the centre of the level and the scale is supported by all four feet Attach the power cable to the connector on the base on the left of the scale Plug in the power cabl...

Страница 9: ...n parts counting or to change from weight to in percent weighing Low Limit High Limit It sets the limits for check weighing and allows setting of either the low limit or the high limit or both None Li...

Страница 10: ...n the pan bAt LO or Low battery The scale is in Percent weighing mode pcs The scale is in Parts counting mode HI OK LO The scale is in Check weighing mode The colons are used to separate pounds from o...

Страница 11: ...he left of the display is a LED to indicate the status of battery charging When the scale is plugged into the mains power the internal battery will be charged If the LED is green the battery is being...

Страница 12: ...scale if small amount of weight is still shown when the platform is empty 10 2 TARING 10 2 1 Manual tare Zero the scale by pressing Zero The zero indicator will be on Place a container on the pan and...

Страница 13: ...g Zero The zero indicator will be on Enter a value using the numeric keys Press Tare to tare the scale The value that was entered is stored as the tare value and it is subtracted from the display leav...

Страница 14: ...gh the samples and determine an average piece weight If the parts are too light to measure accurately the count may become faulty It is suggested that the samples to be weighed should each weigh more...

Страница 15: ...n the scale meets or exceeds the values stored in the memory The memory holds values for a high limit and a low limit Either or both the limits can be set by the user NOTE 1 The alarm and the LED barg...

Страница 16: ...red in pounds and decimal parts of pounds i e 6 0125 lb To set the high limit press High Limit the display will show the high limit the HI symbol will be on to the left side of the display Set the hig...

Страница 17: ...StOrE and rECALL If you want to store the limits press Tare when StOrE is displayed The display shows St Enter a number corresponding to the desired memory location 0 to 9 St X will be displayed for...

Страница 18: ...ale will use a mass on the platform as the 100 reference weight If the platform is empty or the scale is tared then the user can input a reference weight using the keypad Press Func The first option i...

Страница 19: ...the last weight used as a reference press CE to clear and use the numeric keypad to enter a new value Press Tare to accept the new reference weight The weight entered must be greater than 50 scale div...

Страница 20: ...tored in the memory when the Print key is pressed and the weight is stable Remove the weight and press Print when the scale is at zero The display will show ACC 1 and then the weight in memory for 2 s...

Страница 21: ...memory automatically Place a weight on the scale The beeper will sound when the scale is stable indicating the value is accepted Remove the weight The display will show ACC 1 and then the total in the...

Страница 22: ...e RS 232 parameters section for details Data Format Normal Output Only weight value along with the weighing unit is printed If Percent weighing is used then is shown in place of weighing units RS 232...

Страница 23: ...ser ID 234567 cr lf cr lf Net Wt 1 234 Kg cr lf Net Wt or Gross Wt Unit Wt 123 g cr lf g for metric and lb for pounds PCS 10 pcs cr lf cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale...

Страница 24: ...s No Nb Anzhl Num Total weight and count printed Total Total Gesamt Total Print date Date Date Datum Fecha Print time Time Heure Zeit Hora Scale ID number Scale ID Bal ID Waagen ID Bal ID User ID Numb...

Страница 25: ...nt is set the display will show Ld xx Place the suggested calibration mass on the pan It is best to use a weight close to the full capacity of the scale If the mass is different from the displayed val...

Страница 26: ...e will exit the User Parameter section and return to normal weighing 13 1 CHECK WEIGHING PARAMETERS Shortcut to enter this group is to press and hold the Func key for 4 seconds The display will go dir...

Страница 27: ...a spot LED bAr Bar type Spot Spot type oFF Off bAr F4 bEP This parameter sets the Beeper to off or on If set to on the beeper can further be set to sound when the weighing result is within or outside...

Страница 28: ...meter section and return to weighing This group of parameters can be set by the user for setting the language baud rate printing mode etc The user can also set a Scale ID number and a User ID number P...

Страница 29: ...s and hold the Count Key for 4 seconds The display will go directly to S1 Un Press Func to view the list of parameters Press Tare to enter a parameter Press Func to view the options for the parameter...

Страница 30: ...ettings Enter the time manually Enter the date manually 00 00 00 mm dd yy S5 diS Display all weights or only when stable ALL StAb ALL S6 Fi Filter setting to slow normal or fast SLow nor FASt nor S7 S...

Страница 31: ...ight on the pan when turning the scale on Excessive weight on the pan when zeroing the scale Platform is not installed Improper calibration of the scale Damaged load cell Damaged Electronics Err 6 A D...

Страница 32: ...ept ready A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods B Details of the unit purchased This part of information should always...

Страница 33: ...pment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipmen...

Страница 34: ...Adam Equipment Company 2007 32 18 0 APPENDIX BALANCES COM...

Страница 35: ...use harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compliance w...

Страница 36: ...ce computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted...

Отзывы: