background image

ZHT 

100 (6 in 1)

5

OPERATION INSTRUCTIONS

                                        

1. Unscrew and open the battery lid, place a 9V block battery and put back the battery lid.

2. Rotate the probe protection cap as the direction of arrow indicates while measuring, and make sure the sensor is fully exposed.

Press the power button to turn on the unit. To secure a stable reading, place the unit in the target environment for at least 1 minute. 

The relative humidity is displayed on the upper part of the LCD, while the temperature is at lower part. The backlight turns off itself 

in 10s, press any button to bring it back.

3. Switch between Celsius and Fahrenheit by pressing the C/F button. “°C” and “°F” will be shown accordingly.

4. Plug the external probe into unit’s JC port (refer to the product overview), to measure object’s surface and internal temperature.

5. If the external probe is not plugged in, press DEW button, and the temperature will be displayed on LCD screen switching between 

T1 and Dew point only.If the external probe is  plugged in, press DEW button,and the LCD screen will display the difference switch-

ing between T1,Dew point DP,Ambient temperature and ΔT=T1—T2.

6. If the external probe is not plugged in, press WBT button and it only shows WBT reading.If the external probe is plugged in,press 

WBT button, and the LCD screen will display the value switching between Condensation temperature difference and web bulb tem-

perature.If removed, WBT value will be immediately displayed only.

7. Press MAX/MIN button to get the maximum and minimum readings of temperature and humidity,the corresponding value will be 

displayed on the screen. Press continuously until the “MIN” and “MAX” symbol is not displayed to exit MAX/MIN mode.

8. Press HOLD to hold current temperature and humidity readings. Press again the release.

9. “Low battery” icon will be shown on the LCD when battery is low.

10. Press and hold the power button for 3s to power off the unit. When auto power off function is active, the unit will power off itself 

in 20 minutes. Place back the protection cap when the unit is off.

11. Auto power off mode can be deactivated.Press the HOLD button first then press the ON/OFF to power on, with the full-displayed 

information, the auto power off function will be deactivated.

Содержание ZHT 100 (6 in 1)

Страница 1: ...Operating manual Thermo Hygrometer Model ZHT 100 6 in 1 Manufacturer Address WWW ADAINSTRUMENTS COM...

Страница 2: ...uction 3 2 Appearance 3 3 Illustration of display screen 4 4 Operation instructions 5 5 Trouble shootings 8 6 Technical data 8 7 Warranty Exceptions from responsibility 9 Appendix 1 Certificate of acc...

Страница 3: ...ternal temperature probe INTRODUCTION ADAZHT 100 6 in 1 Thermo Hygrometer equipped with advanced sensor technology is used to measure environ mental parameters of storage and production warehouses It...

Страница 4: ...Celsius F Fahrenheit G Probe tempeartureT2 Wet bulb temperature H Wet bulb indicator I Condensation temperature difference T2 DP J Probe temperature K Ambient temperature T1 Dew point DP L Dew point i...

Страница 5: ...the LCD screen will display the difference switch ing between T1 Dew point DP Ambient temperature and T T1 T2 6 If the external probe is not plugged in press WBT button and it only shows WBT reading I...

Страница 6: ...bottle in the market A Please press to deactivate auto power off function and turn the unit on press the upper left button then press the middle power button When the screen be full displayed release...

Страница 7: ...ons and do not burn the batteries Strap insulated tape around the battery charges to avoid unsafe contacts with other objects Many countries have regulations about the batteries disposing Please follo...

Страница 8: ...TA TROUBLE SHOOTINGS Problems Causes Solutions No display on the screen Battery runs down Check and replace the battery is indicated Low battery Replace the battery Backlight Auto off About 10s Auto P...

Страница 9: ...perfect condition and adjustment the user is expected to carry out periodic checks of the product s accuracy and general performance The manufacturer or its representatives assumes no responsibility...

Страница 10: ...oducts or parts caused by misuse including without limitation misapplication or nrgligence of the terms of service instruction 6 Power supply units chargers accessories wearing parts 7 Products damage...

Страница 11: ...r is obligatory Technical examination of instruments for fault identification which is under the warranty is made only in the authorized service center In no event shall manufacturer be liable before...

Страница 12: ...____________________ _____________ name and model of the instrument Corresponds to ______________________________________________________________ designation of standard and technical requirements Dat...

Страница 13: ...ZHT 100 6 1 ADAINSTRUMENTS WWW ADAINSTRUMENTS COM...

Страница 14: ...ZHT 100 6 in 1 14 1 15 1 15 2 16 3 17 4 20 5 20 6 21 1 2...

Страница 15: ...ZHT 100 6 in 1 15 1 2 3 4 5 6 7 MAX MIN 8 9 10 MAX MIN 1 2 3 4 5 6 7 8 9 10...

Страница 16: ...ZHT 100 6 in 1 16 A B C MAX D MIN E F G T2 H I T2 DP J K T1 DP L DP M T1 T2 N 2 P...

Страница 17: ...ZHT 100 6 in 1 17 1 9 2 10 3 F C F 4 10 5 DEW 1 DP DEW DEW 1 2 T T1 T2 DP 1 6 WBT Wb WBT T2 DP Wb 2 7 MAX MIN MAX MIN MIN MAX 8 HOLD 9 10 3 20 11 HOLD ON OFF...

Страница 18: ...ZHT 100 6 in 1 18 1 2 3 4 5 a b 30 6 1 2 1 33 40 40 33 3 2 75 40 40 75...

Страница 19: ...ZHT 100 6 in 1 19 1 2 2...

Страница 20: ...ZHT 100 6 in 1 20 T1 0 C 50 C T2 10 C 70 C 0 99 9 1 C 1 5 C 5 95 3 25 C 0 1 C 0 1 10 20 1 9 6F22 6LR61 0 C 40 C 5 95 RH 30 60 C 85 RH 192 61 31 107...

Страница 21: ...ZHT 100 6 in 1 21 2...

Страница 22: ...1 2 3 4 5 6 7 8 9 WWW ADAINSTRUMENTS COM info adainstruments com...

Страница 23: ..._______________________________________________ ___________________ _________________ ___________________ 24 II 454 491 _________________________________...

Страница 24: ...___________________________ _____________________________________________________________________________ _______________ ______________________________________________________________________________...

Страница 25: ......

Страница 26: ...ADA MEASUREMENT FOUNDATION WWW ADAINSTRUMENTS COM...

Отзывы: