Smart SL-SLEW
: A1007850 - 661Y1700 • F - draft
Maintenance
SL
SLEW
1
Check the power supply.
2
Check the proper operation of the boiler and
the control thermostat of the tank.
3
Check if the charging pump works properly
and
replace if necessary.
4
Check the fuse and replace if necessary.
5
Check the safety thermostat on the tank and
reset if necessary.
6
Check the heating element and replace if
necessary.
FAULT FINDING
What to do if the DHW-water is not heated anymore?
1. Control thermostat [60/80°C]
2. Heating-element-on indicator
3. Summer/Winter switch
4. Fuse FF 12,5 Amp
5. Manual reset high limit thermostat [89°C max.]
6. Electric heating element
EN
36
6
5
1
2
3
4
Содержание Smart SL 100
Страница 5: ...ENERGY LABELLING Smart SL SLEW A1007850 661Y1700 F draft Product Information 5 EN...
Страница 6: ...Smart SL SLEW A1007850 661Y1700 F draft Product Information RATING PLATE EN 6...
Страница 37: ...Smart SL SLEW A1007850 661Y1700 F draft 37 EN...
Страница 38: ...Smart SL SLEW A1007850 661Y1700 F draft EN 38...
Страница 39: ...Smart SL SLEW A1007850 661Y1700 F draft 39 EN...
Страница 40: ......