background image

Smart Green : A1009652 - 661Y3000 • D

Appliance Description

MODELS - 

Smart  130 - 160 - 210 Green

"Smart Green" is a floor-standing hot water storage tank that operates within a 

heating system. Based on the ACV tank-in-tank design, this Energy Label A tank 

uses high performance insulation technology, for  minimized standing loss and 

improved energy efficiency. 

7

EN

1.  Polypropylene top lid

2.  Stainless steel tank (DHW)

3.  Vacuum insulation panel

4.  Dry well

5.  Polypropylene shell

6.  Polypropylene bottom lid

7.  Outer steel tank (primary circuit)

8.  Return connection (primary circuit)

9.  Dip tube

10.  Polyurethane foam insulation

11.  Flow connection (primary circuit)

12.  Control thermostat (60-80°C)

13.  Cold water inlet connection

14.  Auxiliary DHW connection

15.  Manual air bleed valve

16.  Hot water outlet connection

7

5

12

11

10

8

9

13

14

15

16

1

2

4

3

6

Содержание Smart Green 130

Страница 1: ...Smart Green 130 160 210 Installation Operation Maintenance Instructions for the User and the Installer A1009652 661Y3000 D...

Страница 2: ...RIPTION 7 Models Smart 130 160 210 Green 7 TECHNICAL CHARACTERISTICS 8 Dimensions and Main Characteristics 8 Electrical Characteristics 10 Performance 11 INSTALLATION 12 Safety Instructions 13 Packing...

Страница 3: ...Smart Green A1009652 661Y3000 D Table of Contents MAINTENANCE 21 Periodic Checks by the User 21 Annual Maintenance 21 Draining 22 Bringing back into Service after Maintenance 22 3 EN...

Страница 4: ...y only be replaced by genuine parts Our water heaters are designed and manufactured for the exclusive purpose of heating and storing domestic hot water The domestic hot water heaters must only be heat...

Страница 5: ...Smart Green A1009652 661Y3000 D Product Information ENERGY LABELLING 5 EN...

Страница 6: ...Smart Green A1009652 661Y3000 D Product Information RATING PLATE EN 6...

Страница 7: ...ss and improved energy efficiency 7 EN 1 Polypropylene top lid 2 Stainless steel tank DHW 3 Vacuum insulation panel 4 Dry well 5 Polypropylene shell 6 Polypropylene bottom lid 7 Outer steel tank prima...

Страница 8: ...61Y3000 D Technical Characteristics DIMENSIONS AND MAIN CHARACTERISTICS Tank dimensions Smart Green 130 160 210 A mm 1025 1225 1497 B mm 760 960 1232 C mm 235 235 235 Empty weight Kg 55 65 75 EN 8 A B...

Страница 9: ...10 10 Reheat Performance Primary Hea ting Power Input kW 24 7 32 2 39 2 Primary flow rate to achieve Reheat Performance L sec 0 70 0 70 1 25 Reheat time min 10 10 9 Standing Heat Loss kWh 24h 0 84 0 9...

Страница 10: ...10 Rated voltage V 230 230 230 Rated frequency Hz 50 50 50 Max Amp rating A 6 6 6 ELECTRICAL CHARACTERISTICS Wiring diagram 1 Control thermostat 60 80 C 2 Circulator pump option B Blue Bk Black Br Bro...

Страница 11: ...ak flow at 45 C L 10 275 348 469 Peak flow at 60 C L 10 161 209 272 Peak flow first hour at 45 C L 60 911 1156 1560 Peak flow first hour at 60 C L 60 549 689 913 Constant flow at 45 C L h 763 970 1309...

Страница 12: ...sion connect the stainless steel tank directly to the earth Use an adjustable earth clamp see example below on one of the DHW connections to connect to the earth Advised copper wire section 2 5mm Make...

Страница 13: ...teria exists including Legionella pneumophila if a minimum temperature of 60 C is not maintained in both the DHW tank and the hot water distribution network Essential instructions for the electrical s...

Страница 14: ...Package One Smart Green hot water tank Multilingual Installation Operation and Maintenance Instructions One energy label PACKING CONTENTS All appliances are delivered tested and packaged separately T...

Страница 15: ...tank and the safety valve is always open The third DHW tank connection if any can be used for the auxiliary DHW loop If the connection is not used replace the protective plug by a brass plug of the ap...

Страница 16: ...5 Safety valve set at 7 bar 6 Drain valve 7 Hot water outlet 8 Pressure gauge 9 Grounding 10 Stop valve 11 Thermostatic mixing valve CONNECTION TO THE PRIMARY CIRCUIT Typical floor installation Key 1...

Страница 17: ...to the ratio recommended in the local regulations Consult the manufacturer to determine the compatibility of the antifreeze with the tank s construction materials Essential instructions for the correc...

Страница 18: ...ARY CIRCUIT Figure 2 General remark If the tank is used within a heating system refer to the heating boiler manual 1 Check that the drain valve 3 of your primary circuit is tightly closed 2 Open the s...

Страница 19: ...Figure 1 Figure 2 1 3 3 2 2 4 2 3 1 1 Cold water Hot water Smart Green A1009652 661Y3000 D Starting Up 19 EN...

Страница 20: ...t the tank s upper air bleed valve is tight Check that the water side and heat source side pipes are correctly connected and not leaking STARTING UP To put the installation into service refer to the h...

Страница 21: ...y unit drips periodically it may be due to an expansion problem or clogging of the valve For internal inspections the hand hole can be used If there is none use one of the water connections to insert...

Страница 22: ...rcuit of the hot water heater 1 Stop the charging pump 2 Isolate the primary circuit by closing the stop valves 1 3 Connect the drain valve 2 to the sewer using a flexible hose 4 Open the drain valve...

Страница 23: ...Figure 3 Figure 4 4 1 2 3 Cold water Hot water 1 1 2 3 Smart Green A1009652 661Y3000 D Maintenance 23 EN...