installation of a prestige excellence or
prestige solo + a dhW tank Without hot
Water priority
GENERAL DIAGRAM
This configuration allows to control the hot water circuit without hot water
priority. It will be used in applications where heating needs are important in
regard to hot water needs. It is also possible to program a restricted hot water
priority: hot water and heating run in parallel while there is enough power for
hot water. When the boiler is not able anymore to produce enough hot water,
the heating switchs off. The ZMC1 module is able to control a second circuit in
addition
(see preceding configuration)
.
optional accessories
code
description
10800034
Room Unit RSC :
Supplied with outside temperature sensor
10800119
ZMC-1 module (kit) :
Controls the second heating circuit - alarm contact - operates only in conjonction with
the Room Unit RSC.
10800036
Clip-in interface RMCIEBV3 :
Enables communications between the MCBA and the Room Unit RSC.
10510100
Outside temperature sensor 12kΩ — AF120
10800079
Prestige Solo
version only
Domestic hot water hydraulic kit :
Kit to connect a Prestige Solo boiler to an external water heater.
The kit includes :
- one circulator
- one NTC sensor 12kΩ (L = 3,2 m)
- one check valve
- four copper pipes + gaskets
5476g003
NTC sensor 12kΩ :
Senses the temperature in the external hot water tank.
(Delivered with the kit 10800079)
INStAllAtIoN