![ACV MCBA Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/acv/mcba/mcba_manual_2845545006.webp)
21
MCBA FOR SPECIALISTS:
INSTALLER, SERVICE ENGINEER
COMMUNICATION MODE (WITH CODE)
When in this mode, the system displays the communication between
the boiler and the control module, the optional interface kit or the
optional programmable room thermostat.
FAN MODE (WITH CODE)
ERROR MODE (WITH CODE)
“ERROR” mode indicates the most recent error, as well as the
status of the boiler and its readings at the time this error occurred.
Fan speed
MODE
The current fan speed is 5,500 rpm.
STEP
Key
Display
Description of parameters
MODE
Code mode
(See the table on page 16 for a full list)
STEP
Status of the boiler at the time of the
error
(See the table on page 16)
STEP
Start temperature T1 at the time of
the error
MODE
Return temperature T2 at the time of
the error
STEP
Hot water temperature T3 at the time
of the error
STEP
Outdoor temperature T4 at the time of
the error
STEP
Key
Display
Key
Display
Description of parameters
MODE
No communication
Communication between the boiler
module and the optional control
modules only (RMCI)
STEP
Communication between all the
devices connected
Key
Display
Key
Display
Description of parameters
Temp. °C
R
Ω
Temp. °C
R
Ω
-20
98200
40
6650
-15
75900
45
5520
-10
58800
50
4610
-5
45900
55
3860
0
36100
60
3250
5
28600
65
2750
10
22800
70
2340
15
18300
75
1940
20
14700
80
1710
25
12000
85
1470
30
9800
90
1260
35
8050
95
1100
100
950
Temperature sensor resistance tables
Содержание MCBA
Страница 10: ......