24
Chapter 3-8 Alarm Settings
H.264 D1 video server or IP PTZ camera
’s hardware alarm system contains motion detection, alarm
sensors, and one alarm/relay output. Many alarm features such as motion/alarm email notification
and FTP archiving can be found at this section.
Chapter 3-8-1 Motion/Alarm Setup
There are motion detection zones allowed in the H.264 D1 video server or IP PTZ camera. A user
can enable the detection zones with different sensitivities ranging from 1 to 99 (highest to lowest) for
motion detection. Once a suspicious motion activity gets triggered, H.264 D1 video server or IP PTZ
camera can start to capture one JPEG snapshot on various recording mediums.
Chapter 3-8-2 Alarm (DI) Input Detection
Alarm Notification
—
Enable alarm notification.
Alarm Input Mode
—
Normal open/normal close for detecting alarm input
Alarm Output Time
—Trigger alarm output based on the dwell.
For video encoder model, since there are two alarm outputs, a user can specify alarm output time.
Chapter 3-8-3 Motion Area
Once above information get set, please configure the motion area of the monitored environment. To
configure motion area, perform mouse click on the video area.