Prosody X PCI Express R1 Card – Installation Guide
The identification of the input and output of the network termination point is the
responsibility of installation personnel.
120 ohm line interface
Each E1 interface on the card carries one 30-channel service connection via a
screened twisted pair cable of 120 ohm characteristic impedance. There is one
transmit pair and one receive pair.
120 ohm trunk connection
The 8-contact RJ45 modular plug on the cable between the adapter and the network
must be wired as follows:
Pin
Signal
Function
Direction
4 LTT Transmit
(tip) output
5 LTR
Transmit
(ring)
output
1 LRT Receive
(tip) input
2 LRR
Receive
(ring) input
The cable and plug must be shielded types to ensure EMC compliance.
If a cable is to be produced to wire into a network trunk connection, the connector on
the network end of the cable must be wired as appropriate for the network terminating
unit provided.
Service requirements
In case of equipment malfunction, Aculab plc should carry out all repairs. It is the
responsibility of users requiring service to report the need for service to our company.
Service can be obtained from:
Aculab plc
Lakeside, Bramley Road
Mount Farm, Milton Keynes
MK1 1PT
UK
Phone : +44 1908 273800
Fax : +44 1908 273801
E-mail : [email protected]
EN55022 declaration
This is a class A product. In a domestic environment, this product may cause radio
interference in which case the user may be required to take adequate measures.
No changes or modification to the Prosody X PCI Express card are allowed without
explicit written permission from Aculab, as these could void the end user's authority to
operate the device.
34 of 41