Prosody X PCI Express R1 Card – Installation Guide
Appendix B:
USA/Canada approval details
This section applies only to E1/T1 trunk interfaces configured for T1 operation.
FCC connection requirements
This equipment complies with Part 68 of the FCC rules and the requirements adopted
by the ACTA. On the exterior of the cabinet of this equipment is a label that contains,
among other information, a product identifier in the format
US:AAAEQ##TXXXX.
If
requested, this number must be provided to the telephone company.
ACTA Registration Number:
US: 5TCXDNAN PCIEX
Ringer Equivalence Number (REN):
NAN
Facility Interface Code (FIC):
04DU9.1SN, 04DU9.BN, 04DU9.DN &
04DU.1KN
Service Order Code (SOC):
6.0P
USOC Jack Type:
RJ48C
A FCC compliant telephone cord and modular plug is provided with this equipment.
This equipment is designed for connection to the telephone network or premises
wiring using a compatible modular jack that is Part 68 compliant. See Installation
Instructions for details.
The REN is used to determine the quantity of devices that may be connected to the
telephone line. Excessive RENs on the telephone line may result in the devices not
ringing in response to an incoming call. Typically, the sum of RENs should not
exceed five (5.0). To be certain of the number of devices that may be connected to a
line (as determined by the total RENs) contact the local telephone company.
If this equipment causes harm to the telephone network, the telephone company will
notify you in advance that temporary discontinuance of service may be required. But
if advance notice isn't practical, the telephone company will notify the customer as
soon as possible. Also, you will be advised of your right to file a complaint with the
FCC if you believe it is necessary.
The telephone company may make changes to its facilities, equipment, operations or
procedures that could affect the operation of the equipment. If this happens the
telephone company will provide advance notice so you can make the necessary
modifications to maintain uninterrupted service.
If trouble is experienced with this equipment
,
for repair or warranty information,
please contact Aculab INC, Customer Service, 197 First Avenue, Suite 130,
Needham, MA 02494 +1 781 433 6000. There are no user serviceable components
on the card. If the equipment is causing harm to the telephone network, the telephone
company may request that you disconnect the equipment until the problem is
resolved.
Connection to party line service is subject to state tariffs. (Contact the state public
utility commission, public service commission or corporation commission for
information.)
26 of 41