9.5.2
Saving Parameters
After setting one or more parameters as required, users must
write
them
into the sensor memory. Write parameter by clicking
File >Write
parameters
or by clicking the
button.
Be sure to perform testing of the sensor operation with the new parameters.
Once satisfied, it is necessary to store the new parameters in
nonvolatile
memory
by clicking
File > Write to flash
. This procedure saves the
parameters so that upon powering-up in the future will cause the sensor
to default to your new configuration and not factory default configuration.
9.5.3
Saving and Writing a Group of Parameters
Parameters of the sensor can be saved to a file on your computer. This is
done by selecting
File > Write
parameters set and saving the file in the
window offered.
To open a group of parameters from a file, select
File > Sensor
parameters
sets
and select the file required. This function is convenient
for writing identical parameters to several sensors. After loading the
parameters follow the instructions above for saving the parameters to non-
volatile memory.
9.6
Factory Reset
To
restore the sensor’s factory default parameters, use
File > Restore
defaults
. This recalls the factory settings to the interface. It will also be
necessary to save the parameters as described above.