![Acuity AccuRange AR500 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/acuity/accurange-ar500/accurange-ar500_user-manual_2844429022.webp)
AR500 User’s Manual
LLL00xxxx – Rev 1.0
15
When working with the parameters, it should be noted that when the
power is OFF, the parameter values are stored in nonvolatile FLASH-
memory of the sensor. When power is ON, the parameter values are read
out to RAM of the sensor. To retain these changes for the next power-up
state, a special command for saving current parameter values in the
FLASH-memory (04h) must be run.
To issue requests with sizes greater than one byte, set the high
byte ‘session’ then send the low byte request ‘session’.
Refer to Section 11for a list of all requests and parameters and Section 12
for Examples and Clarifications.
5.1.4
Data Stream
‘Data stream’ is an infinite sequence of data bursts or batches transmitted
from ‘slave’ to ‘master’, which can be interrupted by a new request. In
transmission of the ‘data stream’ one of the ‘slaves’ fully holds data
transfer channel, therefore, when ‘master’ produces any new request sent
to any address, the data streaming process is stopped. Also, there is a
special request to stop data streaming.
Содержание AccuRange AR500