Pendant mount

   

This unit must be mounted to a 1-1/2 NPT threaded pendant.  
Verify that the set screw, located in the mounting assembly, is 
backed out enough that it will not interfere with the mounting 
threads.  See Figure 1. Thoroughly inspect threads for damage. 
DO NOT attempt to assemble with another part if any thread 
damage is found on either part. Apply pipe thread sealant 
completely around the first 4 male threads on the mounting 
pendant.  

Force the sealant into the threads

, see Figure 2.   

Thread the mounting assembly onto the pipe threads. Tighten by 
hand at least 5 full turns to ensure the end of the conduit goes past 
the setscrew hole. 

 

CAUTION 

FIELD APPLICATION OF PIPE THREAD SEALANT IS 

REQUIRED.  FAILURE TO PROPERLY APPLY PIPE THREAD 

SEALANT COULD CAUSE THIS UNIT TO LEAK OR 

INADEQUATE THREAD ENGAGEMENT. PIPE THREAD 

SEALANT MUST BE APPLIED TO MALE THREAD ASSEMBLY 

TO ENSURE PROPER INSTALLATION. 

 
 
 

2.2.4

 

Rigid Pendant mounting

 - Thread the mounting assembly 

onto the pipe threads.  Tighten by hand at least 5 full turns to 
insure the end of the conduit goes past the setscrew hole. 
Continue to tighten with wrench until the threads tighten completely 
and the street side of luminaire is pointed in proper direction.  
Reflector assembly and refractor are marked "street side." 
 
 
 
 
 

 
 

Figure 2

 

 

 

GR1060A 

 
2.2.5

  Tighten the set screw to 12-15 ft-lbs. 

 
2.2.6 Stem Mount  

Refer to Installation Manual provided with the swivel fitter (IM-347) 
Attach the luminaire to the fitter by removing fitter door and 
inserting stem of luminaire into the fitter. (Fig 3) Do not to damage 
the electrical supply wires during attachment of the luminaire. Feed 
the electrical supply wires through the center of the stem grommet 
and make final connection per section 2.2.7. Replace the fitter door 
by engaging the lip of the door inside the fitter. Tighten the door 
screws to 5-6 Ft-lbs. Tighten the nuts on the U-bolts to 30-40  
Ft-lbs.  Allow luminaire to self-level and tighten the set screws to 
12-15 Ft-lbs. If necessary, adjust the leveling set screws so that 
the cover fitter is installed level. 
 
Figure 3 

 

 

GR2185 

 

2.2.7

 

Connect the electrical supply wires to the terminal block in 

the back of the electrical chamber.  The terminals are marked "L1" 
(Line 1).  "G" (Ground), and "L2" (Line 2).  If one of the supply lines 
is electrically neutral, it should be connected to terminal "L2".   See  
Figure 1. 

2.2.8

 Hang the electrical assembly on the mounting assembly 

hinge and plug in the electrical connector.  For Esplanade style 
fixtures, swing the electrical assembly closed, engage the closure 
screw and tighten securely.  For Memphis style fixtures, swing the 
electrical assembly closed and engage the latch to the cover catch 
location to securely close fixture.  See Figure 1.   