INSTALLATION GUIDE
Positioning the Fireplace
Using a hand truck or other appropriate equipment,
that is rated to handle the weight of the fireplace
safely move the fireplace into position. (estimated
weight 1500 lbs)
Determine the location of the appliance to ensure that
the combustion air supply and the flue gas/chimney
pipe connections are to be made as designed. The
appliance is designed to sit either directly on the floor
or to sit on a base designed to support the
weight of the appliance for proper elevation.
If shimming is required to level the appliance due to
uneven surfaces, shimming the perimeter of the base
is the preferred method. Anchor the appliance
adequately to prevent future movement.
Note:
The appliance should be positioned in a
manner that planned electrical and gas line access is
available with adequate clearance for servicing.
INSTALLATION GUIDE
9
Clearance to combustibles:
Top of appliance = 4”
Sides of appliance = 2”
Back of appliance = 2”
Bottom of appliance = 0”
Vent clearance to combustibles:
Class A exhaust flue = 2”
B-vent heat relief venting = 1”
IMPORTANT:
Clearances must be in accordance with
local installation codes and the requirements of
the gas supplier.
Les dégagements sont conformes aux codes d’instal
-
lation locaux et aux exigences du fournisseur de gaz.
DRAFT
Содержание circular 4
Страница 8: ...8 INSTALLATION GUIDE D R A F T...
Страница 24: ...SUPPLEMENTAL MATERIAL 24 Gas Valve Ignition Module D R A F T...
Страница 25: ...SUPPLEMENTAL MATERIAL 25 Gas Valve Ignition Module D R A F T...
Страница 35: ...NOTES D R A F T...
Страница 37: ...37 PRODUCT SPECIFICATIONS D R A F T...
Страница 38: ...38 PRODUCT SPECIFICATIONS D R A F T...
Страница 44: ...44 NOTES D R A F T...