Use allen wrench to slide brackets away from the reading head.
Remove alignment brackets and save for future use.
Drill / tap the first end mounting hole / Attach the linear encoder.
Align to within .005 TIR. to -A-, drill / tap second end hole.
Attach the linear encoder / Align to within .005 TIR. to -A-.
Center the axis and mark the reading head mounting holes.
Move axis, drill / tap holes for 8-32 (M4).
Attach head to axis / set leveling screws / secure fasteners.
Use the center support(s) when provided.
Place at equal intervals along the linear encoders length.
Center support
Alignment bracket
removal
Slide brackets away from reading
head and cable.
twist 45°
-A- = Axis travel
1/4-20 x 1 BHCS & Scale flat washer
(M6 x 25mm)
Align to within .005 TIR
to -A-
Drill / tap
for 1/4-20 (M6).
8-32 x 3/4 SHCS
(M4 x 20mm)
Do not tighten prior to adjusting
leveling set screws.
Drill / tap for 8-32 (M4).
ACU-RITE
®
10
Installation Procedure
ENC 150
8-32 x 1 SHCS
(M4 x 25mm)