Chaney and AcuRite atomic clocks use a radio-controlled signal to 

synchronize to the correct time broadcast by the National Institute 

of Standards and Technology (NIST) Radio Station WWVB, 

located near Fort Collins, Colorado. WWVB broadcasts the 

current time and date with split-second accuracy. 

Atomic clocks set themselves and automatically adjust for daylight 

saving time to provide the most accurate timekeeping standard 

possible. 

Introduction

Manual setup allows you to set the clock without the atomic 

signal. After manual setup, the clock will continue to search for 

the atomic signal.

• Press and hold the “M.SET” button (C) for 3 seconds. The 

clock will be in manual time set mode. 

• Press the “M.SET” button to advance the time by 1 minute.

• Press and hold the “M.SET” button to quickly advance the 

hour and minute hands.

• Press the REC button (D) to exit manual time set mode.  

• If no button is pressed for 3 minutes you will automatically 

exit manual time set mode. 

2

1

Overview

SETUP

1. Locate the Time Zone Switch (E) on the back of the clock.  

The switch has four time zone indicators: P, M, C & E 

(P=Pacific, M=Mountain, C=Cental, E=Eastern). Move the 

switch to select your time zone.

2. Slide the “DST” switch (F) to the ON position to allow the 

clock to automatically set itself for daylight saving time (DST). 

On the Spring and Fall DST dates, at 2:00 am, the clock will 

adjust itself until the correct time is reached. If you live in an 

area that does not observe daylight saving time and do not 

want the clock to change, place the “DST” switch in the 

“OFF” position. 

3. Find a suitable location for your clock. For the best possible 

reception, place the clock with the back side facing 

Colorado.

The atomic signal can be impacted by weather conditions, 

electrical interference and solar conditions. Although atomic 

clocks can work in most locations, the number of times they 

sychronize with the atomic signal depends on suitable clock 

placement. Signal reception is especially important for 

automatic daylight saving time updates, which can be 

delayed from poor signal reception.  

4. Insert one fresh 1.5 volt “AA” battery in the battery 

compartment (A) to power on the clock .

5. After the battery is inserted, the second hand will move 

clockwise to the 

12:00 position. Within 5 minutes the hour 

and minute hand will also move to the 

12:00

 standby 

position. The clock will then search for the atomic signal. If 

the signal in your area is strong, the clock will set itself within 

3-12 minutes. NOTE: Due to solar radiation in the 

atmosphere, a radio controlled clock signal is weaker during 

the day. Most synchronization with the atomic signal happens 

at night when there is less interference.

Setup Is Now Complete

Once the atomic signal has been received by the clock, the 

minute hand will advance or slow down as necessary until the 

clock sets itself to the correct time.

SETUP

MANUAL SETUP

Содержание Atomic Clock

Страница 1: ...ompartment Thermometer Calibration The pointer may move during shipping causing the thermometer to read temperature inaccurately If the thermometer is reading incorrectly compare the temperature reading to a known accurate thermometer Let both thermometers adjust to room temperature for at least three hours If the new thermometer continues to read inaccurately adjust the pointer by turning knob on...

Страница 2: ...S ALL LIABILITY FOR THE CONSEQUENCES ARISING FROM THEIR USE OR MISUSE NO PERSON FIRM OR CORPORATION IS AUTHORIZED TO ASSUME FOR CHANEY ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF ITS PRODUCTS FURTHERMORE NO PERSON FIRM OR CORPORATION IS AUTHORIZED TO MODIFY OR WAIVE THE TERMS OF THIS PARAGRAPH AND THE PRECEDING PARAGRAPH UNLESS DONE IN WRITING AND SIGNED BY A DULY AUTHORIZED AGENT OF CHANEY...

Страница 3: ... 00 am the clock will adjust itself until the correct time is reached If you live in an area that does not observe daylight saving time and do not want the clock to change place the DST switch in the OFF position 3 Find a suitable location for your clock For the best possible reception place the clock with the back side facing Colorado The atomic signal can be impacted by weather conditions electr...

Страница 4: ...ted from direct weather elements TROUBLESHOOTING Problem Possible Solution s Poor Signal Place clock near a window with the curtains or blinds open to improve signal reception Place clock more than 3 ft away from electronics or wiring to minimize interference Electronics computers TVʼs fluorescent lights microwaves etc can interfere with signal reception If you do not find good reception on your f...

Страница 5: ...and the clock will go back to the time that was set before the forced reception If the clock does not receive the atomic signal after 12 minutes restart the setup process by pressing the RESET button B Clock does not receive signal after 12 minutes or more TROUBLESHOOTING IMPORTANT NOTICE YOUR PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE www AcuRite com Register this product to receive 1...

Отзывы: