background image

11

Care & Maintenance

Display Unit Care

Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away 

from dust, dirt and moisture. Clean ventilation ports regularly with a gentle puff of air.

Calibration

The indoor / outdoor temperature and humidity readings, and barometric 

pressure can be calibrated on the display unit to improve accuracy. Calibration 

can improve accuracy when sensor placement or environmental factors impact 

the data accuracy.
1. To access calibration mode, press AND HOLD the “

T

”, “SET”, and “

V

” 

buttons simultaneously for at least 5 seconds.

2. To adjust the currently selected (flashing) item, press and release the “

T

“ 

or “

V

“ buttons to calibrate the data value higher or lower from the actual 

reading.

3. To save your adjustments, press and release the “SET” button to adjust the 

next preference. The “ ” icon will remain illuminated next to calibrated 

values.

  The preference set order is as follows: 

OUTDOOR TEMPERATURE 

OUTDOOR HUMIDITY 

INDOOR TEMPERATURE 

INDOOR HUMIDITY 

BAROMETRIC PRESSURE  (must be set to MANUAL mode to calibrate)*

  *To change from AUTO to MANUAL pressure mode and vice versa, press 

AND HOLD the “SET” button for at least 10 seconds. The display indicates 

the current pressure mode selected,“AUTO” or “MANUAL”. 

After 20 seconds of inactivity, the display will save the adjustments and exit 

calibration mode. Note: Calibrations will be erased if the display is reset or if 

batteries are removed and the power adapter is unplugged. 

Calibrate the Rain Gauge

The rain gauge on the 5-in-1 sensor can be calibrated to improve accuracy. 

Items Needed

: 5-in-1 sensor, display unit, plastic cup, pin, screw driver

1.  First, ensure 5-in-1 sensor is perfectly level using built-in bubble level.
2.  Place display unit close so you can monitor it during calibration.
3.  Make a pin hole in the bottom of a plastic cup. Hold the cup over the rain gauge 

and fill it with exactly 1 cup (8oz) of water, allowing the water to drip into the rain 

gauge. You should hear the internal buckets tip and see water drain through the rain 

gauge.

Содержание 01057RM

Страница 1: ... smartHUB will take a minute to start up POWER ON During startup the blue status lights will illuminate CREATE YOUR ACCOUNT 7Create your account and register your smartHUB at www MyAcuRite com or within the AcuRite mobile app Note It may take up to 10 minutes for the smartHUB to communicate with the My AcuRite servers OR DEVICE ID WRITE DOWN THE smartHUB Device ID printed on the bottom of the devi...

Страница 2: ... Chaney Instrument Co All rights reserved AcuRite is a registered trademark of the Chaney Instrument Co Lake Geneva WI 53147 All other trademarks and copy rights are the property of their respective owners AcuRite uses patented technology Visit www AcuRite com patents for details Limited 1 Year Warranty AcuRite is a wholly owned subsidiary of Chaney Instrument Company For purchases of AcuRite prod...

Страница 3: ... model 06016RM PRODUCT REGISTRATION Register online to receive 1 year warranty protection www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE Register a Product Package Contents 1 Display unit with tabletop stand 2 Power adapter 3 Instruction Manual This product requires an AcuRite 5 in 1 Weather Sensor sold separately to be operational ...

Страница 4: ...2 Features Benefits Display Unit 1 3 2 4 1 27 29 21 24 25 26 28 30 5 7 9 11 14 15 12 6 8 13 10 16 17 18 19 20 22 23 ...

Страница 5: ... Pressure Arrow icon indicates direction pressure is trending 16 RAINFALL Button Press to change the RAINFALL data being displayed Month Year All Time 17 T Button for setup preferences 18 SET Button for setup preferences 19 V Button for setup preferences 20 SELECT Button Press to change the WEATHER SELECT category data being displayed 21 Weather TickerTM 22 Heat Index Wind Chill Alert Indicator 23...

Страница 6: ...tary backlight while on battery power 3 Plug in for Power Adapter 4 Removable Tabletop Stand 5 CLEAR ALL RESET Button Press and HOLD for 10 seconds for full reset to factory defaults 6 A B C Switch ID code that must match 5 in 1 sensor s A B C switch to ensure units synchronize 7 Power adapter 8 Battery Compartment Cover not shown 1 3 2 4 5 6 7 ...

Страница 7: ...charge non rechargeable batteries DO NOT short circuit the supply terminals IMPORTANT Batteries are a backup power source to preserve records in the event of a power outage Power adapter is the recommended primary power source to enjoy the full functionality of this product Display Unit Setup AcuRite recommends high quality alkaline batteries for the best product performance Heavy duty or recharge...

Страница 8: ...AST You will automatically exit SET MODE if no buttons are pressed for 20 seconds Enter SET MODE at any time by pressing the SET button Display Backlight Settings This weather station s color display features three different lighting settings High 100 brightness Medium 60 brightness and Low 30 brightness Using battery power alone the backlight is available momentarily for 10 seconds by pressing th...

Страница 9: ...ocation View the complete list of icons at www AcuRite com acurite icons Weather Select Weather Select displays data including wind chill dew point heat index feels like days with rain this month and days since last recorded rainfall To change the Weather Select category shown press the SELECT button on the front of the display SNOW RAIN MIX LIKELY CHANCE OF RAIN SNOW LIKELY STORMY WINDY CLOUDY fl...

Страница 10: ...L RAINFALL 2 MONTHS AGO TOTAL RAINFALL CURRENT YEAR TOTAL RAINFALL PREVIOUS YEAR TOTAL RAINFALL ALL TIME TOTAL RAINFALL date shown is start date of the all time total the date the display was powered on Previous rainfall is the amount of rain recorded from 12 00am to 11 59pm on the date shown TOTAL RAINFALL FOR DATE SHOWN TOTAL RAINFALL FOR MONTH SHOWN CURRENT YEAR TOTAL RAINFALL ALL TIME TOTAL RA...

Страница 11: ... TEMP XXX RECORDED MM DD YY 24 HOUR TEMP CHANGE XX ALL TIME HIGH WIND XX MPH RECORDED MM DD YY 7 DAY AVERAGE WIND XX MPH TODAY S AVERAGE WIND XX MPH MOON NEW MOON WAXING CRESCENT MOON FIRST QUARTER MOON WAXING GIBBOUS MOON FULL MOON WANING GIBBOUS MOON LAST QUARTER MOON WANING CRESCENT INDOOR HUMIDITY OK INDOOR HUMIDITY HIGH INDOOR HUMIDITY LOW NEW LOW TEMP RECORD XX NEW HIGH TEMP RECORD XX NEW WI...

Страница 12: ...ing lever is moving freely by dripping a little water through the rain collector You should hear the lever tipping If you do not hear it you may need to clean inside the sensor Video available at www acurite com 5in1 Inaccurate wind readings What is wind reading being compared to Pro weather stations are typically mounted at 30 ft high or more Make sure to compare data using a sensor positioned at...

Страница 13: ...ows OUTDOOR TEMPERATURE OUTDOOR HUMIDITY INDOOR TEMPERATURE INDOOR HUMIDITY BAROMETRIC PRESSURE must be set to MANUAL mode to calibrate To change from AUTO to MANUAL pressure mode and vice versa press AND HOLD the SET button for at least 10 seconds The display indicates the current pressure mode selected AUTO or MANUAL After 20 seconds of inactivity the display will save the adjustments and exit c...

Страница 14: ...il an equal number of water drops are tipping the buckets Then restart the calibration procedure If you don t hear the buckets tipping and see water dripping alternately out of each drain there may be an issue with the rain gauge or it s adjustment See Troubleshooting on page 15 Adjustment If the rain gauge doesn t register close to 1 06 make an EQUAL adjustment to the two calibration screws on th...

Страница 15: ... and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one...

Страница 16: ...ies are hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose Chaney expressly disclaims all liability for special consequential or incidental damages whether arising in tort or by contract from any breach of this warranty Some states do not allow the exclusion or limitation of incidental or con...

Страница 17: ...15 ...

Страница 18: ... AcuRite uses patented technology Visit www AcuRite com patents for details It s More than Accurate it s AcuRite offers an extensive assortment of precision instruments designed to provide you with information you can depend on to Plan your day with confidence www AcuRite com Weather Stations Temperature Humidity Weather Alert Radio Kitchen Thermometers Timers Clocks Printed in China 06016RM INST ...

Страница 19: ...her Sensor model 06014RM Package Contents 1 5 in 1 PRO Weather Sensor 2 Mounting Hardware 3 Sensor Mounting Bracket 4 Instruction Manual PRODUCT REGISTRATION Register online to receive 1 year warranty protection www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE Register a Product ...

Страница 20: ...eating resulting in more accurate temperature measurement 3 A B C Switch ID code that must match display s A B C switch to ensure units synchronize 4 Battery Compartment 5 Temperature Humidity Sensors internal 6 Mounting Point 7 Wind Speed Anemometer 8 Wind Direction Vane 9 Mounting Bracket 10 Mounting Hardware includes anchors screws Qty Diameter Length 5 4 3 4 1 4 1 2 1 6 1 2 11 Debris Filter Pr...

Страница 21: ... 4ºF 20ºC Remove Rain Gauge Stabilizer Locate and remove the rain gauge stabilizer plastic tab taped into the bottom of the sensor The rain gauge will not function until this is removed 2 3 1 PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS BATTERY SAFETY Clean the battery contacts and also those of the device prior ...

Страница 22: ...alls metal surfaces or other objects that may limit wireless communication LOCATE AWAY FROM HEAT SOURCES Position sensor away from heaters air conditioners chimneys exhaust vents asphalt and concrete surfaces that radiate heat LOCATE AWAY FROM HUMIDITY SOURCES Avoid installing the sensor near pools spas or other bodies of water Water sources may impact humidity accuracy LOCATE AWAY FROM SPRINKLER ...

Страница 23: ...r with the solar cell facing SOUTH This ensures the cell receives as much sun as possible and orients wind direction 5 in 1 Sensor Installation 1 Fasten mounting base included to a post or pole not included using the 4 longer screws included in the hardware bag 2 Insert the mounting base into the hole on the bottom of the sensor 3 Make sure the arrows on the top of the sensor are pointed in the pr...

Страница 24: ...ister 1 06 Tips There should be nearly an equal number of water drops about 25 water drops between bucket tips If not adjust the calibration screws on the bottom of the 5 in 1 sensor until an equal number of water drops are tipping the buckets Adjustment If the rain gauge doesn t register close to 1 06 make an EQUAL adjustment to the two calibration screws on the bottom of the 5 in 1 sensor Turnin...

Страница 25: ...d by a duly authorized agent of Chaney This warranty gives you specific legal rights and you may also have other rights which vary from state to state For in warranty claims Chaney Instrument Co 965 Wells St Lake Geneva WI 53147 Limited One Year Warranty FCC Information This device complies with part 15 of FCC rules Operation is subject to the following two conditions 1 This device may NOT cause h...

Страница 26: ... AcuRite uses patented technology Visit www AcuRite com patents for details Printed in China 06014RM INST 090215 It s More than Accurate it s AcuRite offers an extensive assortment of precision instruments designed to provide you with information you can depend on to Plan your day with confidence www AcuRite com Weather Stations Temperature Humidity Weather Alert Radio Kitchen Thermometers Timers ...

Отзывы: