14. Maximum Cable Length
3
2
OPTIONAL
REMOTE SENSOR AND DUCT BEAD SENSOR
LM-RS-2
OPTIONAL
REMOTE SENSOR
AERSS
OPTIONAL
DUCT BEAD SENSOR
TO
PACKAGE UNIT PCB
WALL CONTROLLER
C7-4
FAMILY
MASTER BED
RUMPUS
BEDROOM 1
1
3
2
4
FAN
CONTROL
SET
TEMP
AUTO
HEAT/COOL
TIMER
DISPLAY
EXIT
CANCEL
RESTORE
REPEAT
TIME CLOCK
PROGRAM
ON
OFF
CONT HIGH LOW AUTO HEAT COOL RUN STAGE ROOM
MON TUE WED THU FRI SAT SUN TIMER FILTER AH
AM
PM
SET BACK EVENT 1 2
o C TIME CLOCK ON OFF
PACKAGE UNIT
1
2 CORE 14/0.20 (0.44mm)
Shielded Data Cable
NOTES
• Diagram shown above is a general representation only. Refer to individual unit wiring diagram for complete wiring
connection details.
• Long runs beside Mains cables or TV antenna cables should be avoided where possible.
Item
Description
Maximum Cable Length *
1 to 2
Outdoor PCB to Master Controller
50 m (60 m without CZ-1)
2 to 3
Master Controller to Remote Sensor (Max. of 2 Optional Sensors)
50 m each
*Total Cumulative length of all the aggregate cable lengths must not exceed 500 meters. Consult ActronAir for longer cable
length requirement.