Installation and Commissioning Guide - Split Ducted Variable Capacity Commercial Indoor Unit
Doc. No. 0525 - 068
Ver. 3 201104
Installation and Commissioning Guide
Variable Capacity Commercial
2 Core Twisted Data Cable Shielding Instructions
(ActronAir Part Number: AEDC2)
NOTES
• Maintain the twist of the core wires up to the Green Terminal Plug.
• Maximum strip length of outer insulation to the Green Terminal Plug is 50mm.
• Make sure the cable colours used for the Data Terminal in Outdoor Unit match the Data Terminal in Indoor unit.
Outdoor Unit Data Terminal (Green Plug)
“Terminal A” - White Wire
“Terminal B” - Black Wire
“Terminal G” - Shield Wire
Indoor Unit Data Terminal (Green Plug)
“Terminal A (+)” - White Wire
“Terminal B (-)” - Black Wire
“Terminal G” - Shield Wire
Insert data cable through the lower snap bushing and first cable tie on the right hand side of the electrical panel.
Connect core wires and shield wire into the Outdoor Board green terminal plug marked “ INDOOR A, B and G”.
(Refer to unit wiring diagram for complete wiring connection details).
OUTDOOR
BOARD
OUTDOOR BOARD
TERMINAL PLUG
CIRCUIT BREAKER SIZE AND CABLE SIZE REQUIREMENT
Model
Circuit Breaker Size
Cable Size
*
(mm
2
)
Amps
MAIN
O.D. to I.D.
EVA290T / EVA330T
32.0
6.0
1.0
*
Suggested Minimum Cable Size should be used as a guide only, refer to the latest edition of the AS/NZS 3000
“Australian / New Zealand Wiring Rules” for more details.