![ActronAir ERQ2-16AS Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/actronair/erq2-16as/erq2-16as_installation-and-commisioning-manual_2844125015.webp)
Installation and Commissioning Guide
ESP Platinum QUE - Three Phase
15
ActronAir is constantly seeking ways to improve the design of its products, therefore specifications are subject to change without notice.
Copyright © 2019 Actron Engineering Pty. Ltd.
09. Indoor Unit Wiring Diagram
DESIGNS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
FIELD WIRING BY
INSTALLER
REFER TO QUE CONTROL SYSTEM
INSTALLATION & COMMISSIONING
MANUAL FOR WIRING INSTRUCTIONS
IF-1
1 EC
ECM
CONTROL
MODULE
INDOOR FAN (IF)
INTERNAL AUTO RESET
OVERLOAD PROTECTION
FERRITE
EMC-1
E
N
A
N
A
PCB JUMPER PIN
POSITION TABLES
Jumper Pin
Position
A/C Model
D
PCB Model: QUEIB3-1
C
B
A
E
ERQ3-18AS
ERQ5-21AS #
ERQ5-24AS #
N/A
ERQ2-16AS
EART
H
N
EUT
ACT
EC
C
O
N
TR
O
L
FERRITE
FIELD WIRING BY INSTALLER -
CABLE MUST BE 2 CORE 7/0.30 SHIELDED
TWISTED PAIR DATA CABLE WITH SCREEN
WIRE CONNECTED TO TERMINAL "G" ON
OUTDOOR & INDOOR UNIT
POWER
& DATA
(YELLOW
CAT5E
CABLE)
POWER
ONLY
(YELLOW
CAT5E
CABLE)
M
A
ST
ER
SE
CO
NDA
RY
- O
PT
IO
NA
L
WiFi
WiFi
RF
RF
MODULATION
ZONING
QUEIB
DATA
ZONE
8
ZONE
7
ZONE
6
ZONE
5
ZONE
4
ZONE
3
ZONE
2
ZONE
1
TO ZONE 2 - 8
240V
MAINS
ZONE
MOTOR
ZONE
CONTROL 1
REMOTE
SENSOR 1
LOG
RJ45 SOCKETS FOR ACTRON AIR
CAT5E SPEC CABLES ONLY
REFER TO QUE CONTROL SYSTEM
INSTALLATION & COMMISSIONING
MANUAL FOR ALL AVAILABLE
CONFIGURATIONS
FIELD WIRING
RF
RF
OPTIONAL WIRED
CONNECTION
- POWER ONLY
TO
O
UT
DO
O
R
UNI
T
8Z-VAQ DATA CABLE
(GREEN CAT5E CABLE)
SEE JUMPER PIN POSITION
TABLES FOR CORRECT SETTING
INDOOR
COIL IN
SENSOR
D
AT
A
MAINTAIN TWISTED
PAIR UNTIL TERMINAL
ON QUEIB
SHIELD
WIRE
O
U
TD
OOR
A
G
B
DESIGNS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
FIELD WIRING BY
INSTALLER
REFER TO QUE CONTROL SYSTEM
INSTALLATION & COMMISSIONING
MANUAL FOR WIRING INSTRUCTIONS
IF-1
1 EC
ECM
CONTROL
MODULE
INDOOR FAN (IF)
INTERNAL AUTO RESET
OVERLOAD PROTECTION
FERRITE
EMC-1
E
N
A
N
A
PCB JUMPER PIN
POSITION TABLES
Jumper Pin
Position
A/C Model
D
PCB Model: QUEIB3-1
C
B
A
E
ERQ3-18AS
ERQ5-21AS #
ERQ5-24AS #
N/A
ERQ2-16AS
EART
H
NE
UT
ACT
EC
C
O
N
TR
O
L
FERRITE
FIELD WIRING BY INSTALLER -
CABLE MUST BE 2 CORE 7/0.30 SHIELDED
TWISTED PAIR DATA CABLE WITH SCREEN
WIRE CONNECTED TO TERMINAL "G" ON
OUTDOOR & INDOOR UNIT
POWER
& DATA
(YELLOW
CAT5E
CABLE)
POWER
ONLY
(YELLOW
CAT5E
CABLE)
M
A
ST
ER
SE
CO
NDA
RY
- OP
TI
ON
AL
WiFi
WiFi
RF
RF
MODULATION
ZONING
QUEIB
DATA
ZONE
8
ZONE
7
ZONE
6
ZONE
5
ZONE
4
ZONE
3
ZONE
2
ZONE
1
TO ZONE 2 - 8
240V
MAINS
ZONE
MOTOR
ZONE
CONTROL 1
REMOTE
SENSOR 1
LOG
RJ45 SOCKETS FOR ACTRON AIR
CAT5E SPEC CABLES ONLY
REFER TO QUE CONTROL SYSTEM
INSTALLATION & COMMISSIONING
MANUAL FOR ALL AVAILABLE
CONFIGURATIONS
FIELD WIRING
RF
RF
OPTIONAL WIRED
CONNECTION
- POWER ONLY
TO
O
UT
DO
O
R
UNI
T
8Z-VAQ DATA CABLE
(GREEN CAT5E CABLE)
SEE JUMPER PIN POSITION
TABLES FOR CORRECT SETTING
INDOOR
COIL IN
SENSOR
D
AT
A
MAINTAIN TWISTED
PAIR UNTIL TERMINAL
ON QUEIB
SHIELD
WIRE
O
U
TD
OOR
A
GB
R
R
This drawing remains the intellectual property of Actron Engineering Pty Ltd.
Reproduction, modification and/or distribution are prohibited without written consent.
This drawing remains the intellectual property of Actron Engineering Pty Ltd.
Reproduction, modification and/or distribution are prohibited without written consent.
Rev.
Rev.
Description
Description
Date
Date
By
By
PCR
PCR
ORIGINAL
ORIGINAL
A
A
QUE INDOOR BOARD
WITH 2 TOUCH CONTROLLERS
QUE INDOOR BOARD
WITH 2 TOUCH CONTROLLERS
Revision
Revision
Description:
Description:
A
A
WD2022
WD2022
A5
A5
Size:
Size:
Base
Model No:
Base
Model No:
Variation:
Variation:
VARIOUS
VARIOUS
Variation Code:
Variation Code:
Drawing No:
Drawing No:
Drawn:
Drawn:
Date:
Date:
02-11-2018
02-11-2018
RL
RL
Approved:
Approved:
MJH
MJH
Date:
Date:
15-01-2019
15-01-2019