CHANGING THE BALLAST 

(continued)

LAMP INDICATOR

6.  Place new ballast into original 

location and secure using the 
two (2) nuts removed in step 4.

7.  Replace cover and secure with 

the original four (4) screws.

8.  Re-install unit if removed from duct. 

Reconnect power and check for 
proper operation (Lamp indicator 
should be lit when in operation).

Содержание INDUCT 10000

Страница 1: ...READ MANUAL CAREFULLY FOR PROPER PROCEDURES AND OPERATION Electronic Air Purification System...

Страница 2: ...Please record the serial number of your activTek INDUCT 5000 10000 Serial _________________________________________ CONGRATULATIONS This owner s manual is also available online at http www activTek n...

Страница 3: ...river Phillips Screwdriver 3 8 Drill Bit if installing into fiberglass ducting with toggle bolts 1 4 1 4 Nut Driver Bit 8 8 75 1 4 Self tapping screws Item US70679 4 6 32 X 2 inch Threaded bolts Item...

Страница 4: ...elements WARNING If installed near a furnace or where emergency heat coils could raise the temperature inside the plenum cycle the AC unit through three full heating cycles assuring that the temperat...

Страница 5: ...5...

Страница 6: ...6 ACTIVTEK INDUCT 5000 10000 CELL HOLE PLACEMENT TEMPLATE activTek INDUCT 5000 Min 10 x 10 activTek INDUCT 10000 Min 12 x 12...

Страница 7: ...7...

Страница 8: ...8...

Страница 9: ...lation 3 Using a 4 4 inch hole saw cut opening s into duct work Cut the second hole for activTek INDUCT 10000 only 4 Place the mounting plate squarely into place and fasten to duct work with sheet met...

Страница 10: ...licensed HVAC installer or qualified electrical contractor only 120VoltUnit BlackWire L1 WhiteWire Neutral GreenWire Ground 220VoltUnit BlackWire L1 WhiteWire L2 GreenWire Ground InternationalUnit Bro...

Страница 11: ...G THE ACTIVEPURE CELL WARNING UV Light in operation Disconnect unit from power supply before servicing Failure to follow warnings may result in severe eye damage 2 Remove the activTek INDUCT ballast a...

Страница 12: ...prevent accidental exposure to electrical energy 3 Remove the two 2 thumb nuts on the top and bottom side of the ballast to pull ballast from assembly 4 Remove the wires from ballast by pressing a sma...

Страница 13: ...t into original location and secure using the two 2 nuts removed in step 4 7 Replace cover and secure with the original four 4 screws 8 Re install unit if removed from duct Reconnect power and check f...

Страница 14: ...hrough activTek Distributors only Warranties are voided if a product is purchased through unauthorized channels this includes websites that are not authorized touseactivTek strademarkednames imagesand...

Страница 15: ...15...

Страница 16: ...installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communicatio...

Отзывы: