10
WIRING THE UNIT
1.
Connect wires coming from the activTek INDUCT 5000/INDUCT 10000
unit to the fan relay as follows:
NOTE: Disconnect power at the breaker or fuse panel before servicing unit. Always follow OSHA
lockout procedures to prevent accidental exposure to electrical energy.
2. Connect the unit to the load side of the proper fan relay.
3. Be sure to ground the ballast by securing the unit to the metal
surface of the AC unit or power box.
4. Check indicator light for proper operation with fan on.
NOTE: All units come standard with a blunt cord.
WARNING: Hard wiring unit into HVAC system should be done by a licensed HVAC installer or
qualified electrical contractor only.
120 Volt Unit:
Black Wire L1
White Wire Neutral
Green Wire Ground
220 Volt Unit:
Black Wire L1
White Wire L2
Green Wire Ground
International Unit:
Brown Wire L1
Blue Wire Neutral
Green with
Yellow Stripe Ground
Your activTek INDUCT 5000/10000 unit requires no periodic maintenance
beyond normal replacement of the ActivePure® cell every year. UV bulb
has an effective life of 9,000 hours.
NOTE: For optimal performance, we recommend the replacement of
the ActivePure® cell every year, even if the UV lamp appears to be
operating normally.
The UV lamp operation indicator on the face of the unit will glow when
the UV lamp is in use. If the indicator does not glow and the unit has
power, the ActivePure® cell should be replaced.
Lamp Indicator
MAINTENANCE/UV LAMP INDICATOR