Activeforever AquaGuard Скачать руководство пользователя страница 9

AquaGuard Owner’s Guide

  

RJE Technologies, Inc. 

 

 

10 

The Detector Unit's "anti-theft" alarm will sound if the Unit is dismantled while the 
system is on. Enter 

1234

 on the Detector unit keypad to deactivate the "anti-theft" 

alarm. 

STEP 6  -  Mount the Detector Unit Base Plate (optional) 

 

Turn off the system by pressing 1234*99 before opening the detector.   

 

Mark the location of the Detector Unit on the pool deck. Remove the Detector Unit from the 
pool.  

 

Remove the two screws at the rear of the Detector Unit, and slide the base plate off the 
Detector Unit housing. Remove the batteries from the Detector Unit to prevent the "anti-
theft" alarm from activating.  

 

Place the base plate at the previously marked position. Use a permanent marker to 
mark the locations of the three holes in the base plate. Set the base plate aside.  

 

Use a drill and ¼”(7 mm) masonry bit to drill three holes, ¾” (19 mm) deep, at the 
marked locations.  

Be sure

 to drill the holes straight and perpendicular to the surface of the pool deck. If the 

hoes are drilled at an 

angle

, the base plate may not secure properly. 

 

Install one plastic insert (provided) into each of the drilled holes.  

 

Place the base plate on the pool deck over the drilled holes. Secure the base plate to 
the pool deck with the three screws provided.  

 

Re-install the batteries in the Detector Unit. Place the Detector Unit housing over the 
base plate. Lift up slightly on the rear of the housing. Slide the tab on the front of the 
base plate into the slot in the nose of the Detector Unit housing; then lower the housing 
onto the base plate.  

 

Re-install the two screws at the rear of the Detector Unit. 

STEP 7  -  Confirm the System is On and Armed 

 

Wait 6 to 10 minutes to allow the unit to automatically “arm.” When the water has 
stabilized and the unit is “armed”, the 

“ARMED” 

LED will blink and the beep sequence 

will repeat.  

 

Establish the radio link as described in step 4.  

 

Repeat the tests described in step 5. 

 
 
 
 
 

 

 

 

Extreme environmental conditions (strong wind, heavy rain) can affect AquaGuard’s 
performance, or in rare cases, cause a false alarm. The time required to return to “armed” 
mode under these conditions may be longer than normal. 

 

In order to properly 

detect

, the AquaGuard Detector Unit 

must

 be installed within 

22 feet (7 

meters)

 of all possible fall locations. Larger pools should be equipped with an 

additional

 

Detector Unit to meet this requirement. (Maximum 2 detectors on a pool) 

 

Pools with perimeter overflow are not compatible with AquaGuard. 

 

Vanishing edge (Infinity or zero edge) pools typically require two AquaGuard Detector Units. 

Tools Required 

You will need the following tools and materials to install and test the AquaGuard system: 

 

Marking pen 

 Flat-head 

screwdriver 

 

Drill 

  2.5 (19.5 liter) gallon water container 

 

¼” (7 mm) Masonry drill bit 

 Rope 

 

Phillips-head screwdriver 

Installation 

Permanent installation of the Detector Unit on the pool deck (as described in STEP 6) is 

optional

STEP 1  -  Choose the Detector Unit Installation Site 

 

The Detector Unit 

must

 be installed within 

22 feet (7 meters)

 of all possible fall locations 

and must have 

direct

 view of the rest of the pool. In most cases, this location will be at 

the 

middle

 of the 

longest side

 of your pool. Typical examples of installation are shown 

below. 

22 FEET

(7 METERS)

22 FEET

(7 METERS)

22 FEET

(7 METERS)

22 FEET

(7 METERS)

 

 

Be sure

 that the Detector Unit 

is not

 installed next to any pool features (jets, water 

features, etc.) that may cause disturbance.  

 

Be sure

 that the Detector Unit can be accessed easily.  

 
 

 

Содержание AquaGuard

Страница 1: ...OWNER S MANUAL Revision 1 3...

Страница 2: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference with radi...

Страница 3: ...except conditions that do or will affect performance Conditions resulting from improper pool maintenance water level and pool equipment usage Items consumed through use Warranty Disclaimers and Additi...

Страница 4: ...and other life saving techniques Keep the pool area CLEAR of toys and other obstructions Keep the water CLEAN and uncontaminated Keep security gates CLOSED when the pool is unattended IF AN ACCIDENT O...

Страница 5: ...at the rear of the Detector Unit 6 The system will now start the arming sequence The Detector Unit will emit 10 short beeps followed by one long beep indicating that the system is armed The rear LED...

Страница 6: ...ivity in the pool while system is in ARMED mode Siren sounds Siren sounds Press any key on the Detector Unit keypad or Press the OK key on the Remote Unit once Immediately determine whether an acciden...

Страница 7: ...FF To turn the system OFF Enter 1234 99 on the Detector Unit keypad To turn the system ON Enter 1234 on the Detector Unit keypad Managing the System You can use the LED indicators and alarm siren on t...

Страница 8: ...e your home Be sure to verify that the alarm can be heard inside your home when testing the system during installation Care should be taken to place the Remote Unit in an accessible location and in di...

Страница 9: ...m is On and Armed Wait 6 to 10 minutes to allow the unit to automatically arm When the water has stabilized and the unit is armed the ARMED LED will blink and the beep sequence will repeat Establish t...

Страница 10: ...to the wall outlet Wait for remote unit to establish radio link with detector This may take up to 5 minutes Remote Unit will beep once when RF Link has been established and Armed LED should be blinkin...