STEP 2  -  Position the Detector Unit at the Chosen Site 

 

Place the Detector Unit at the installation site so the Sensor Tube extends into the 
water. 

 

Make sure

 the bottom of the Sensor Tube is between 

5 - 7 inches (13 – 18 cm) below the water’s surface. 

If the Sensor Tube is too short, install a Tube 
Extension on the Sensor Tube to meet the required 
depth (see 

 

 

 
Assembling the Detector Base Unit and Sensor

 

Tube

 on page 6 for details). 

If the Sensor Tube is too long, it may be necessary to cut the Tube to the proper length. 
BE SURE the water in the pool is at its normal level before measuring. Fill the pool if 
necessary. BE SURE to measure carefully before cutting the Tube. 

If the tube end is at less than 5 inches (15 cm), unwanted alarms may occur. If the tube 
end is deeper than 7 inches (18 cm), the unit’s “detection” sensitivity will be decreased. 

STEP 3  -  Choose a Location for the Remote Unit 

 

The Remote Unit 

must

 be placed within 100 feet (33 meters) of the Detector Unit and in 

direct line of sight.  

The Selected location should have as few obstructions between the Remote Unit and 
the Detector Unit as possible. Interior and exterior walls or other obstacles will reduce 
the range of the Remote Unit. 

 

The remote must be at the same level or a level above the pool. The ideal location 
would be a window overlooking the pool. 

 

Do not place the remote unit in an underground basement. 

 

Choose a location that will allow the Remote Unit alarm to be heard throughout the 
house.  

 

Choose a location that is near an AC outlet to allow the Remote Unit to be powered by 
the AC adapter.  

The Remote Unit must 

always

 be powered by the AC adapter. The battery is for back-up 

and emergency use 

only

STEP 4  -  Establish the Radio Link 

The AquaGuard system uses a radio transmitter/receiver to allow communication between 
the Detector Unit and the Remote Unit. You 

must

 establish the radio link to use the Remote 

Unit to monitor and control your AquaGuard system. Perform the following: 

 

Power up the Remote Unit by plugging the AC Adapter into the wall outlet. 

 

Wait for remote unit to establish radio link with detector. This may take up to 5 minutes. 

 

Remote Unit will beep once when RF Link has been established and “Armed” LED 
should be blinking if detector is armed. 

5 - 7 INCHES

(13 - 18 CM)

 

 

 

Press the 

OK

 button on the Remote Unit three times to put the Detector Unit into “swim” 

mode, then press the 

OK

 button on the Remote Unit three times again to put the Detector 

Unit into “armed” mode. 

STEP 5  -  Test the System for Detection 

Prepare a Test Simulator 

 

Fill a 2.5-gallon (19.5 liter) water container with enough water to weigh approximately 18 
pounds (8 kg). 

 

Tie a 6-foot (1.8 meter) length of rope to the container handle.  

Perform Test One 

 

Make sure

 both the 

“ARMED”

 LED on the Detector Unit and the “green” LED on the 

Remote Unit are on.  

If the LEDs 

are not

 on, the system 

is not

 “armed”. Allow 

additional time

 for the water in 

the pool to settle enough to allow the Detector Unit to “arm.” 

 

Place the test simulator on the edge of the pool, 4 - 6 feet (1.2 – 1.8 meters) from the 
Detector Unit.  

 

Hold the rope, and roll the test simulator into the pool. Both the Detector Unit and the 
Remote Unit alarms should sound.  

If the alarms 

do not

 sound, it may be necessary to change the location of the Detector 

Unit. 

Reset the System 

 

Press any key on the Detector Unit keypad to turn the alarm off.  

 

Remove the test simulator from the pool.  

 

Wait 6 to 10 minutes to allow the unit to automatically “re-arm.” When the water has 
stabilized and the unit is “armed”, the 

“ARMED”

 LED will blink and the beep sequence 

will repeat.  

Perform Test Two 

 

Make sure

 both the 

“ARMED”

 LED on the Detector Unit and the “green” LED on the 

Remote Unit are on.  

If the LEDs 

are not

 on, the system 

is not

 “armed”. Allow 

additional time

 for the water in 

the pool to settle enough to allow the Detector Unit to “arm.” 

 

Place the test simulator on the edge of the pool, at the point 

farthest

 from the Detector 

Unit, not to exceed 22 feet (7 meters). 

 

Hold the rope, and roll the test simulator into the pool. Both the Detector Unit and the 
Remote Unit alarms should sound.  

If the alarms 

do not

 sound, it may be necessary to change the location of the Detector 

Unit. 

Reset the System 

 

Press any key on the Detector Unit keypad to turn the alarm off.  

 

Remove the test simulator from the pool.  

Содержание AquaGuard

Страница 1: ...OWNER S MANUAL Revision 1 3...

Страница 2: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference with radi...

Страница 3: ...except conditions that do or will affect performance Conditions resulting from improper pool maintenance water level and pool equipment usage Items consumed through use Warranty Disclaimers and Additi...

Страница 4: ...and other life saving techniques Keep the pool area CLEAR of toys and other obstructions Keep the water CLEAN and uncontaminated Keep security gates CLOSED when the pool is unattended IF AN ACCIDENT O...

Страница 5: ...at the rear of the Detector Unit 6 The system will now start the arming sequence The Detector Unit will emit 10 short beeps followed by one long beep indicating that the system is armed The rear LED...

Страница 6: ...ivity in the pool while system is in ARMED mode Siren sounds Siren sounds Press any key on the Detector Unit keypad or Press the OK key on the Remote Unit once Immediately determine whether an acciden...

Страница 7: ...FF To turn the system OFF Enter 1234 99 on the Detector Unit keypad To turn the system ON Enter 1234 on the Detector Unit keypad Managing the System You can use the LED indicators and alarm siren on t...

Страница 8: ...e your home Be sure to verify that the alarm can be heard inside your home when testing the system during installation Care should be taken to place the Remote Unit in an accessible location and in di...

Страница 9: ...m is On and Armed Wait 6 to 10 minutes to allow the unit to automatically arm When the water has stabilized and the unit is armed the ARMED LED will blink and the beep sequence will repeat Establish t...

Страница 10: ...to the wall outlet Wait for remote unit to establish radio link with detector This may take up to 5 minutes Remote Unit will beep once when RF Link has been established and Armed LED should be blinkin...

Отзывы: