background image

 

QUICK START GUIDE 

HARRIER AF-ZOOM SDI CAMERAS 

Version 1.0.1 - March 2022

 

 

March 2022

 

Page 5 of 10 

 

Setting up the System 

To get the Harrier AF-Zoom SDI camera running, follow the instructions below (also see figure 8): 
 

1.

 

Connect the 9-way 1.0mm pitch FFC connector on the camera (J202 / J205 shown below) to 
the FFC breakout board using the 9-way 1.0mm pitch FFC cable.  
 

         

               

 

 

2.

 

Connect the 10-way wire cable from the FFC breakout board to the Harrier Evaluation Board 
I/O connector (J103).  See figure 8. 

3.

 

For capturing 

analog

 

camera output

 connect the J301 (Analog) BNC socket on the Harrier 

Evaluation Board to an analog monitor/display using a suitable coaxial cable. 

4.

 

For 

EX-SDI/HD-SDI

 

camera output

, connect the MMCX-BNC adaptor cable to the MMCX 

socket on the top of the camera.  Using a 75 Ohm 3G-SDI/HD-SDI digital video quality BNC 
cable, connect the BNC end of the adapter to an EX-SDI/HD-SDI capable monitor/display.  

5.

 

For 

serial communications 

with the camera, use the mini USB–USB Type-A cable to 

connect the mini USB socket (CN1) on the Harrier Evaluation Board to a PC.  The USB PWR 
LED should light up indicating a live connection to the PC.  Three serial interfaces will appear 
as COM ports on the PC and be accessible to PC software, one of these will be the serial 
connection to the camera and can be used with th

HarrierControl

 command line software, 

or other serial control applications, to communicate with the camera.  The HarrierControl 
application can be downloaded a

www.activesilicon.com

 from the 

Software

 page. 

6.

 

Set the Harrier Evaluation Board power switch (SW302) to OFF (left viewed from above). 

7.

 

Connect the power supply barrel connector to the Harrier Evaluation Board power input 
connector (J306). 

8.

 

Plug in the power supply and switch ON the Harrier Evaluation Board power switch (SW302).  
The PWR ON should light up.  

9.

 

The camera will make audible mechanical noises as it goes through its power up sequence 
and after a short time the video outputs will start working. 
Note: the camera will power up in the last video mode used, some monitors cannot display 
all the modes supported by the camera (notably 1080p30).  If you have no visible SDI output 
use the HarrierControl application to check/change the EX-SDI/HD-SDI video output mode 
set on the camera to ensure that the camera output can be displayed on the SDI monitor. 

10.

 

If an analog monitor is connected to the Harrier Evaluation Board, and the camera analog 
output is enabled you will see the camera output on the analog monitor. 

11.

 

If the EX-SDI/HD-SDI output is connected you will see the camera output on the  
EX-SDI/HD-SDI monitor/display.

 

 

J202 

J205 

Содержание AS-CIB-3GSDI-002-EVAL-B

Страница 1: ...ier 36x AF Zoom SDI Camera AS CAM 36SGHD A This document should be read in conjunction with the Harrier AF Zoom SDI camera technical reference manual and other documents available on Active Silicon s...

Страница 2: ...eparately Please check that you have all the parts listed below Harrier Evaluation Board Figure 2 9 way FFC breakout board with 10 way wire cable and 9 way FFC cable Figure 3 MMCX BNC adapter cable Fi...

Страница 3: ...BNC adapter cable example only actual part may be different Figure 5 Harrier Evaluation Board cables only for use with the Harrier 3G SDI Camera Interface Board Figure 6 30 way micro coax cable KEL ca...

Страница 4: ...rd is connected to a PC using the mini USB cable the Windows 10 operating system will see three virtual COM ports these ports are automatically assigned incrementing numbers by Windows To identify the...

Страница 5: ...ssible to PC software one of these will be the serial connection to the camera and can be used with the HarrierControl command line software or other serial control applications to communicate with th...

Страница 6: ...ou may need to install the latest drivers from FTDI These are available here https www ftdichip com Drivers D2XX htm The HarrierControl application is Windows 10 command line program that relies on se...

Страница 7: ...ation can be used with command line arguments as follows HarrierControl P1 P2 P3 P4 Argument P1 This specifies the type of Interface Serial communication to be used displays help text h displays help...

Страница 8: ...tation for your camera Argument P4 This is an optional parameter If you set P4 to P HarrierControl will attempt to parse the command and response and print a description of the command response on the...

Страница 9: ...SDI mode use the HarrierControl application or other serial control software to send the VISCA command that changes the SDI output format Command CAM_RegisterValue 8x 01 04 24 mm 0p 0q FF mm mm regis...

Страница 10: ...mail to techsupport activesilicon com Headquarters Active Silicon Ltd Pinewood Mews Bond Close Iver Bucks SL0 0NA UK Tel 44 0 1753 650600 Fax 44 0 1753 651661 Email info activesilicon com Website www...

Отзывы: