Questions? Call 866.621.4933 or visit www.activecaremed.com.
Pilot Owner’s Manual
24
The diagnostic flash codes for your scooter are designed to help you perform basic
troubleshooting quickly and easily. A diagnostic flash code flashes from the Status
LED in the event one of the conditions listed below develops.
Table 2: Scooter Controller Internal Diagnostics
Flash
code
Possible Cause
Solution
1
The battery needs charging.
The battery voltage has
dropped below 23.3 volts in
neutral. Recharge batteries.
2
Battery voltage is too low.
The battery has dropped
past 16.5 volts and is not
sufficient to allow safe
driving. Check the battery
condition and the
connections.
3
Battery voltage too high
The battery has exceeded 32
volts. Check the battery
condition and the
connections.
4
Current limit time out
The motor current has
reached too high a value.
Check the condition of the
motor and loom. Contact
your Service Agent.
5
Park brake fault
Check park brake conditions.
6
Speed control out of neutral
Return speed pod to neutral
and rest system. Readjust
the speed lever to neutral if
necessary. Contact your
Service Agent.
7
Speed control fault
Check speed pod wiring for
open or short circuits. Check
speed pot set-up. Contact
your Service Agent.
8
Motor fault
Contact your Service Agent.
9
Internal (controller) fault
Contact your Service Agent.
Содержание Pilot 2310