11. Connecting the gas cylinder and checking for leaks
Observe the following safety-related instructions for the gas supply installation:
Read the instructions before installation!
Observe the recommended frequency of checking the pipelines and hose lines (at least
once a month and every time the liquid gas cylinder is replaced) and the need for regular
replacement if indicated on the pipelines or hose lines.
The following parts are required to connect the unit:
•
Commercially available camping gas bottle 5 - 11kg filling weight, e.g., grey camping
propane gas bottle. You buy these from a liquid gas dealer. The empty cylinder is re-
placed for refilling.
•
Fixed, DVGW-approved pressure reducer, max. 1.5 kg/h, operating pressure 50
mbar, suitable for the gas cylinder used included in delivery.
•
DVGW-approved hose line of sufficient length (included in the scope of delivery)
which allows kink-free installation. It is part of the appliance. A porous or damaged
hose line must be replaced immediately. The hose line is already pre-assembled at
the factory.
•
Leak detection agent, e.g., leak detection spray or soapy water.
1. Check the presence and proper condition of the cylinder valve thread seal, also at
each cylinder change. Do not use any additional seals.
2. Connect the union nut of the pressure regulator to the cylinder valve thread by turning
it counter clockwise by hand. Do not use any tools, as this may damage the cylinder
valve seal and thus the tightness is no longer guaranteed.
3. The hose line must be connected firmly and tightly to the pressure regulator outlet
thread by turning it to the left using an SW 17 spanner.
4. The connection of the other end of the hose line to the threaded connection piece of
the unit is already pre-assembled. This connection must also always be very tight. Al-
ways check all connections carefully before using the appliance.
5. Check all connections for leaks under operating pressure using a leak detector. Leak
tightness is ensured if no bubbles form.
Checking for leaks with an open flame is not permitted. Leaky or damaged hoses and
fittings must be replaced without exception
6. In the event of gas leaks, shut off the gas supply immediately and repair the leak or
replace the defective part.
Содержание 12241 Dakota
Страница 6: ...Art Nr 12241 Dakota Seite 6 von 23 D 7 Exploded view ...
Страница 10: ...Art Nr 12241 Dakota Seite 10 von 23 D A M6x10 4 Pieces Step 5 A M6x10 4 Pieces Step 6 ...
Страница 11: ...Art Nr 12241 Dakota Seite 11 von 23 D Step 7 A M6x10 4 Pcs F Collar screw 4 Pcs Step 8 ...
Страница 12: ...Art Nr 12241 Dakota Seite 12 von 23 D Step 9 A M6x10 4 Pcs Step 10 ...
Страница 13: ...Art Nr 12241 Dakota Seite 13 von 23 D C M4x10 2 Pcs Step 11 C M4x10 2 Pcs Step 12 ...
Страница 14: ...Art Nr 12241 Dakota Seite 14 von 23 D C M4x10 2 Pcs Step 13 Step 14 ...