background image

Page 5

© 2005 Active Research Limited

General features

4 NMEA 0183 data input ports

Each NMEA 0183 input port has a priority level. This is fixed

to the logical order that matches the port numbers, i.e. port 

1 has the highest priority and port 4 has the lowest.

An NMEA 0183 data combined output port

This  output  combines  the  input  data  into  one  standard 

NMEA output. The NMEA inputs and output have the same 

baud rate. This means that the output can only carry as 

much data as one of the inputs - therefore the combined 

data from all four NMEA input channels could exceed the 

data carrying capacity of the NMEA output channel. The 

combiner  contains  special  software  to  ensure  that  when 

the output channel is overloaded, new data of the same 

type as older data, still in the buffer, will overwrite the older 

sentence.  This  will  only  happen  when  the  output  load 

becomes too high, and ensures that the combiner cannot 

build  up  excess  old  data  in  the  case  where  the  output 

stream is fully loaded or overloaded.

A PC compatible RS-232 bi-directional port

A PC can use the RS-232 port to read all the NMEA data 

traversing through the NDC. This allows for the possibility 

of a “virtual cockpit” of instruments displaying all available 

data  in  any  manner  the  user  requires  (available  from  a 

number of manufacturers).

Technical features

High-speed  micro-controller

  capable  of  10  million 

instructions per second.

Flash  ROM  technology

  that  supports  automatic 

programming for quick and easy updates, 10,000+ erase 

cycles  and  a  10-year  Data  Retention  provides  carefree 

user configuration.

On-chip  memory  store

  allows  buffering  of  short  term 

NMEA data, allowing the unit to smooth short-term peaks 

in the NMEA data flow.

NMEA 0183 inputs

 are opto-isolated differential inputs to 

fully comply with the NMEA 0183 standard specification.

This allows the inputs to work correctly with long cable runs 

and in a noisy environment. Typical operating voltage is 

2.0v to 15.0v. The unit can wit/- 35v continuously, 

and +/- 40v transients. The Opto-isolator can protect any 

upstream equipment (chart plotter, laptop PC, radar etc.) 

from up to 2000v of common mode voltage difference.

NMEA 0183 full-differential output driver

.  This can drive 

up to 15 fully compliant NMEA 0183 device loads, with a 

30mA  (maximum)  drive  capability.  The  full-differential 

output  ensures  better  quality  communications  and  lower 

noise emissions on unshielded twisted pair cabling.

Full  specification RS232 interface

ensures  that  any 

marine electronic device (or PC) that has an RS-232 port 

receives  all  the  input  NMEA  data,  and  can  add  its  own 

NMEA data to the combined output. This connection also 

allows the unit to be updated via the free flash upgrade

software that will be made available on the 

Actisense™

 

website if the NDC-3 software has been enhanced.

Wide  battery  input  voltage  range

  to  offer  maximum 

compatibility, the NMEA 0183 NDC-3 can operate from a 

battery supply anywhere between 8 and 35 volts.

Low Power Consumption 

that is typically 26-30mA at 12 

volts and 16-18mA at 24 volts.

A  diagnostic  LED

  indicates  the  operation  mode  of  the 

NDC-3, if any faults have been detected, or the peak load 

currently on any one of the NMEA inputs.

Very  tough  Polycarbonate  case

  is  certified to IP66

(classified as “totally protected against dust and protection

against  low  pressure  jets  of  water  from  all  directions”). 

Being Polycarbonate, it is also incredibly strong, offering 

a wide temperature range and superior protection to the 

electronics  inside.  The  IP66  rating  of  the  case  is  only 

limited by the sealing gasket strip, which can be enhanced 

by applying a suitable non-acid based marine sealant to 

the gasket after wiring and testing. This will allow use of 

the unit in areas where salt spray could enter, accidental 

immersion may occur, or in environments where maximum 

long-term reliability is paramount.

Robust Nylon grommets

 are certified to IP68 (classified

as immersible for long periods without water ingress). Note 

that  to  achieve  this  level  of  water  integrity  all  grommets 

must be occupied by round-section cables.

Large  range  of  possible  cable  diameters

  of  between 

4.5 mm and 10 mm, single or multi-pair wire types can be 

easily accepted.

Software updates

The  NDC-3’s  built-in  firmware is held in “flash” memory,

allowing quick and easy upgrades using a simple Microsoft 

Windows (95/98/ME/NT/2000/XP) user interface program 

(Flash Centre) running on a connected PC.

It is our policy to provide these updates free on our website, 

www.actisense.com

, so that your combiner can become 

more  sophisticated  with  time,  and  should  there  be  any 

bugs reported in the software, they can be promptly fixed

without the unit coming out of commission. This upgrade 

can be performed with the unit completely in-situ, via a PC 

connected to the RS232 port.

Содержание NDC-3

Страница 1: ...er NDC 3 B User Manual Issue 1 31 Multiple talker interface for use with the NMEA 0183 standard Serial data networking of marine electronic devices instruments Personal computer RS232 interface to NME...

Страница 2: ......

Страница 3: ...mpatible RS 232 bi directional port 5 Technical features 5 Software updates 5 Connecting devices together 6 The basics 6 The NMEA signals 6 The different NMEA standards 6 Connections 7 Connecting to N...

Страница 4: ...n the NMEA sentence is validated Therefore the electronic device s supplying the NDC 3 with NMEA data retain s the sole responsibility for the NMEA data s validity Foreword Actisense recognises that i...

Страница 5: ...m drive capability The full differential output ensures better quality communications and lower noise emissions on unshielded twisted pair cabling Full speci cation RS232 interface ensures that any ma...

Страница 6: ...ine Tx or Out and used the ground as the other line similar to the way a computer serial port works This connection method is referred to as single ended instead of the differential method used by NME...

Страница 7: ...to a Personal Computer PC or other marine device capable of interfacing to a standard RS 232 port 4 Battery supply input Note 1 To complete the NMEA 0183 standard all device interconnection NMEA cable...

Страница 8: ...connection ID s Simply connect A to A and B to B refer to gure 2 NMEA Talker device 3 This device does not conform completely to the NMEA 0183 standard However by connecting to A and its G Ground to t...

Страница 9: ...ine and one for the RX line Use the spare wire in each pair as ground and connect the cable shield to ground only at the computer end 3 The TX of the NDC 3 should be connected to the RX of the compute...

Страница 10: ...ion Also indicates that no data is currently being received by the NDC 3 hardware Green Flashing 1 10 per second Normal and data Rx mode No error No response required A normal operation mode that indi...

Страница 11: ...e reduces to 2v 32 mA Output short circuit current 50 55 mA Baud rate xed see note 3 4 8 kbit sec Data propagation delay 1 0 100 ms RS 232 Input voltage range 15 15 V Input voltage threshold LOW 0 8 1...

Страница 12: ...202 746682 International 44 1202 746682 Fax 01202 746683 International 44 1202 746683 Actisense on the Web For advice support and product details E mail support actisense com Website www actisense com...

Отзывы: