Product Specification 

 

TCM-5111

 • Device

Device Type

Box Camera

Image Sensor

Progressive Scan CMOS

Sensor Size

1/3” (4.8 x 3.6 mm)

Day / Night

Yes

Minimum Illumination

Color: 0.5 lux at F1.0 (30 IRE, 2400°K)

B/W: 0.05 lux at F1.0 (30 IRE, 2400°K)

Color to B/W switch

CDS sensor based switch

Mechanical IR Cut Filter

Yes

IR Sensitivity Range

700 - 1100 nm

IR LED

No

Electronic Shutter

1/30 - 1/1,000 sec (60Hz); 1/25 - 1/1,000 sec (50Hz) (manual mode)

1/5 - 1/15,000 sec (auto mode)

• Lens

Focal Length

Fixed focal, f4.2 mm / F1.8

Iris

Fixed iris

Focus

Manual Focus

Mount Type

C/CS mount (interchangeable lens)

Horizontal Viewing Angle

64.4°

• Video

Compression

H.264, MPEG-4 SP, MJPEG

Maximum Frame Rate
vs. Resolution

18 fps at 1280 x 1024 (SXGA); 26 fps at 1280 x 720 (HD 720p) ; 30 fps at 640 x 480 (VGA);

30 fps at 320 x 240 (QVGA); 30 fps at 160 x 112 (QQVGA)

Multi-Streaming

Simultaneous dual streams based on two configurations

Bit Rate

28 Kbps - 6 Mbps (per stream)

Bit Rate Mode

Constant, Variable

S/N Ratio

More than 44 dB

Image Enhancement

White balance: automatic, hold, predefined and manual; Brightness; Saturation; Contrast; Sharpness;

Automatic gain control; Auto exposure: automatic, predefined and manual; Flickerless

Privacy Mask

4 configurable regions

Text Overlay

User defined text on video

Image Orientation

 Image flip and mirror

• Network

Protocol & Service

TCP, UDP, HTTP, HTTPS, DHCP, PPPoE, RTP, RTSP, IPv6, DNS,

DDNS, NTP, ICMP, ARP, IGMP, SMTP, FTP, UPnP, SNMP, Bonjour

Ethernet Port

1, Ethernet (10/100 Base-T), RJ-45 connector

Security

IP address filtering; HTTPS encryption; Password protected user levels; IEEE 802.1X network access

control

• Alarm

Alarm Trigger

Video motion detection (3 regions)

Alarm Response

Notify control center; Change camera settings; Command other devices; E-mail notification with snapshots;

Upload video, snapshot to FTP server

• General

Power Source / Consumption

PoE Class 3 (IEEE802.3af) / 4.51 W

Weight

400 g (0.88 lb)

Dimensions (Φ x H)

67 mm x 55 mm x 129.5 mm (2.64” x 2.17” x 5.10")

Operating Temperature

-10 °C ~ 50 °C (14 °F ~ 122 °F)

Operating Humidity

10% ~ 85% RH

Approvals

CE, FCC

• Integration

Unified Solution

Fully compatible with ACTi software

ISV Integration

Software Development Kit (SDK) available

Firmware Access Browser

Microsoft Internet Explorer 6.0 or newer

Содержание TCM-5111

Страница 1: ...TCM 5111 H 264 Megapixel IP D N PoE Box Camera Ver 2011 11 29...

Страница 2: ...1 Introduction 4 Package Contents 4 Features and Benefits 5 Safety Instructions 6 Physical description 8 Basic Connections 9 Product Specification 10 2 Accessing Camera 11 If you have DHCP server rou...

Страница 3: ...ng the writing of this manual Please inform your local office if you find any inaccuracies or omissions We cannot be held responsible for any typographical or technical errors and reserve the right to...

Страница 4: ...www acti com TCM 5111 Hardware User s Manual 4 1 Introduction Package Contents TCM 5111 Product CD Warranty Card Accessory...

Страница 5: ...tuning the object size and sensitivity it will reliably detect objects passing though in view Hardware motion detection also offers better sensitivity and faster response time than software motion det...

Страница 6: ...en sink or laundry tub in a wet basement or near a swimming pool and the like Don t use accessories not recommended by the manufacturer Only install this device and the power supply in a dry place pro...

Страница 7: ...t of other controls may result in damage and will often require extensive work by a qualified technician to restore the video product to its normal operation Safety Check Upon completion of any servic...

Страница 8: ...reset button The Power LED light will flash on for 3 second first turn off for about 15 seconds flash on for another second and turn off again By this time the reset to default operation is already co...

Страница 9: ...o connect the IP device to the respective apparatuses You have to use a PoE Power over Ethernet supported switch or injector 1 Connect your IP Box Camera to the Switch Injector by CAT5 or CAT6 cables...

Страница 10: ...ge Enhancement White balance automatic hold predefined and manual Brightness Saturation Contrast Sharpness Automatic gain control Auto exposure automatic predefined and manual Flickerless Privacy Mask...

Страница 11: ...t detail Software ACTi_Utility_Suite If you do NOT have DHCP server router in your network 1 Configure your PC to use the same subnet by changing your PC s IP address to the subnet with prefix 192 168...

Страница 12: ...efault User Admin Password 123456 6 After logging in you will see the video from camera To go to the main menu click the Setup button on the top left Please set the settings as below IP address 192 16...

Страница 13: ...used IP address so that when the next device is connected to the network no two devices use the same IP Please perform the following steps 7 Go to IP Settings Connection Type 8 Change the IP mode to S...

Страница 14: ...Apply Internet Explorer will close after a few seconds This is normal 12 Wait for 30 seconds and open IE again to connect to the new IP In this example 192 168 0 101 For the second device or more you...

Страница 15: ...www acti com TCM 5111 Hardware User s Manual 15...

Отзывы: