Method 2: Using the Flush Mount 

You can use the 

PMAX-1008

 flush mount to mount the camera on ceilings. 

 

Prepare the following: 

 

PMAX-1008 Flush Mount 

 

Drilling template 

 

Screws (3) 

 

Foam rubber pads (3) 

 

Jig saw (not supplied) 

 

Phillips screwdriver (not supplied) 

   

To mount the camera, follow the procedures below: 

 

1)

 

Drill a Hole on the Ceiling 

Drill a 184-mm diameter hole on the ceiling where you want to mount the camera, then route the 

network cable through the hole. 

 

 

 

 

Содержание KCM-3311

Страница 1: ...Encoder Firmware V4 06 09 User s Manual KCM 3311 3 6x Zoom H 264 4 Megapixel IP D N PoE Indoor Dome with P Iris Advanced WDR 2013 10 31...

Страница 2: ...ction 5 Package Contents 5 Physical Description 6 Installation 8 Method 1 Surface Installation 8 Method 2 Using the Flush Mount 9 Adjusting the Viewing Angle 19 Accessing the Camera 21 If you have DHC...

Страница 3: ...riting of this manual Please inform your local office if you find any inaccuracies or omissions We cannot be held responsible for any typographical or technical errors and reserve the right to make ch...

Страница 4: ...e personnel under the following conditions 1 When the power supply cord or plug is damaged 2 If liquid has been spilled or objects have fallen into the video product 3 If the inner parts of the video...

Страница 5: ...www acti com Hardware Manual 5 Introduction Package Contents KCM 3311 QIG Accessories Warranty Card Drill Template...

Страница 6: ...ond first turn off for about 15 seconds flash on for another second and turn off again By this time the reset to default operation is already completed This will take around 20 seconds from power up Y...

Страница 7: ...he Power Button and then camera will reboot automatically 3 Ethernet Port The IP device connects to the Ethernet via a standard RJ45 connector Supporting NWAY this IP device can auto detect the speed...

Страница 8: ...wall or the ceiling and directly install the camera on a surface To do this follow the procedures below 1 Drill the holes Using the supplied drill template in the camera package mark the holes on the...

Страница 9: ...the following PMAX 1008 Flush Mount Drilling template Screws 3 Foam rubber pads 3 Jig saw not supplied Phillips screwdriver not supplied To mount the camera follow the procedures below 1 Drill a Hole...

Страница 10: ...www acti com Hardware Manual 10 2 Remove the Camera Casing Remove the three 3 screws to detach the camera casing...

Страница 11: ...w acti com Hardware Manual 11 3 Prepare the Flush Mount 1 Unpack the flush mount 2 Peel off the lining of the three 3 foam rubber pads and attach a rubber pad to each retaining bracket Retaining brack...

Страница 12: ...www acti com Hardware Manual 12 4 Attach the Camera to the Mount 1 Align the screw holes on the camera to the screw holes on the mount 2 Attach the three 3 screws to secure the camera to the mount...

Страница 13: ...taining Brackets Using a screwdriver loosen the retaining brackets according to the thickness of the ceiling 6 Connect the Network Cable Route the network cable to pass through the gap of the mount an...

Страница 14: ...s are flat on the ceiling 2 Position the retaining brackets to hold the mount on the ceiling NOTE The following illustration shows how the flush mount will look like when viewed from inside the ceilin...

Страница 15: ...amera has zoom lens and auto focus capabilities so you do not need to manually adjust the focus Position the lens on the target view area To accurately position the target area view the camera s Live...

Страница 16: ...ng 1 Align the screw holes on the camera and the camera casing 2 Attach the three 3 screws supplied with the flush mount package to secure the camera casing 10 Attach the Flush Mount Cover 1 Align the...

Страница 17: ...www acti com Hardware Manual 17 2 Push to firmly secure the flush mount cover latches The mounted camera should look like the image below...

Страница 18: ...t the camera or reposition the lens follow the procedures below 1 Use your fingers to pry the flush mount cover off the ceiling 2 Insert a pointed object through the reset hole or position the lens 3...

Страница 19: ...mera Parts Overview Adjustment Procedures 1 Loosen the tilt adjustment screws adjust the tilt and then tighten back the screws to fix the tilt position 2 Move the rotation adjustment to rotate the vie...

Страница 20: ...e Manual 20 NOTE If you need to tighten or loosen the pan adjustment knob and adjustment by hand is not enough insert the bundled pan bracket wrench into the hole on the knob and then push it to the l...

Страница 21: ...y changing your PC s IP address to the subnet with prefix 192 168 0 XXX The last number should be anything from 1 to 254 except 100 and other occupied IP addresses Subnet mask should be 255 555 255 0...

Страница 22: ...192 168 0 100 5 When you see the login window please input default user and password Default User Admin Password 123456 6 After logging in you will see the video from camera To go to the main menu cli...

Страница 23: ...0 101 or any other unused IPs Do NOT use the PC s IP address or 192 168 0 100 If this is not the first device you add to the network please also avoid other devices IPs 10 Click Apply 11 Please go to...