Adding a Card Batch using the keypad:
Step
Keypad Entry
Operation
1
16
Add Card Batch
2
Enter 10-digit card number
10-digit First Card number with
leading zeros
. Eg. Card
54321 enter 0000054321.
3
Enter 10-digit card number
Second Card number
4 1-8,
(optional)*
Select each door this Card is deleted from
5 Press
✔
End Adding Card Batch
Deleting a Card or Card and PIN using the keypad:
Step
Keypad Entry
Operation
1
17
Delete Card or Card and PIN
2
Enter 10-digit card number
10-digit Card number with
leading zeros
. Eg. Card 54321
enter 0000054321.
3 1-8,
(optional)*
Select each door this Card is deleted from
4 Press
✔
End deleting Card (Card and PIN)
Set Door Relay Time:
Step
Keypad Entry
Operation
1
20
Set Door Relay Time – (default 5 seconds)
2 Enter
3
digit time
000-255 seconds – (
leading
zeros
required).
3
1-8 (optional)*
Select each door this timer is set for
4 Press
✔
End setting Door Relay Timer
Set Door Ajar Time:
Step
Keypad Entry
Operation
1
21
Set Door Ajar Time – (default 30 seconds)
2 Enter
3
digit time
000-255 seconds – (
leading
zeros
required).
3
1-8 (optional)*
Select each door this timer is set for
4 Press
✔
End setting Door Ajar Time
Set Guest Buzzer Time:
Step
Keypad Entry
Operation
1
22
Set Guest Buzzer Time – (default 2 seconds)
2 Enter
3
digit time
000-255 seconds – (
leading
zeros
required).
3
1-8 (optional)*
Select each door this timer is set for
4 Press
✔
End setting Guest Buzzer Time
Change Programming Code:
Step
Keypad Entry
Operation
1 23
Change
Programming
code
2
0001-9999
New 4 - 8 digit programming code
Change Number of PIN Digits:
Step
Keypad Entry
Operation
1
24
Change Number of PIN digits
2
4-8
Select number of PIN digits in range 4 to 8. When set, the codes
require
leading zeros
Eg. Code 9999 becomes 009999 for 6 digits.