7.2 Service and Repair 

Warranty period

:

 1-year limited warranty 

 
Warranty Section from ACT’s PURCHASE ORDER TERMS AND CONDITIONS 

 

 

Buyer’s Property.

 All drawings, tools, fixtures, materials and other items supplied or paid for by Buyer 

shall be and remain the property of Buyer. All such items shall be used only in the performance of work 

under this Order unless Buyer consents otherwise in writing. Seller shall have the obligation to maintain 

any and all property furnished by Buyer to Seller and shall be responsible for all loss or damage to said 

property except for normal wear and tear. 

 

Warranty.

 Seller warrants that all Goods furnished under this Order shall conform to all specifications 

and appropriate standards, will be new, and will be free from defects in material or workmanship. Seller 

warrants that all Goods furnished hereunder will be merchantable, and will be safe and appropriate for 

the purpose for which Goods of that kind are normally used. If Seller knows or has reason to know the 

particular purpose for which Buyer intends to use the Goods, Seller warrants that such Goods will be fit 

for such particular purpose. Inspection, test, acceptance or use of Goods furnished hereunder shall not 

affect Seller’s obligations under this warranty, and such warranty shall survive inspection, test, 

acceptance and use. Seller’s warranty shall run to Buyer, its successors, assigns and customers, and 

users of products sold by Buyer. Seller agrees to replace or correct defects of any Goods not 

conforming to the foregoing warranty promptly, without expense to Buyer, when notified of such 

nonconformity by Buyer, provided that Buyer elects to provide Seller with an opportunity to do so. In the 

event of failure of Seller to correct defects in or replace nonconforming Goods, Buyer, after reasonable 

notice to Seller, may make such corrections or replace such Goods and charge Seller for the costs 

incurred by Buyer in doing so. Seller shall be liable for and save Buyer harmless from any loss, damage, 

or expense whatsoever that Buyer may suffer from a breach of these warranties. 

 

Inspection and Acceptance.

 All Goods are subject to Buyer’s inspection, testing and approval, both at 

Seller’s facility and Buyer’s point of destination. Buyer reserves the right to reject and refuse acceptance 

of any Goods which do not comply with all the terms of this Order. Acceptance, payment, use, or resale 

of Goods by Buyer shall not release Seller of any of Seller’s obligations, representations, or warranties 

hereunder. Payment for any Goods shall not be deemed an acceptance hereof. 

 
Please see ACT’s current full Terms & Conditions:

 

https://www.1-act.com/termsandconditions/

 

 

Disclaimer 

The warranty is limited to the delivered product(s) and ACT is not responsible for any loss that may be derived 

by equipment failure. 

 

 

 

Содержание ACT-VCC-5000

Страница 1: ...ACT VCC 5000 AC Cabinet Air Conditioner User Manual Read this manual carefully before installation and use...

Страница 2: ...s 4 2 3 Working Principles 4 2 4 Product features 4 2 5 Technical Specifications 5 2 6 Air Circulation and Remote Mounting 5 2 7 Operation of the Unit 6 2 8 Condensate Handling 6 2 9 LED Display Param...

Страница 3: ...e cooling device intended for applications where the internal air of a sealed electrical enclosure must be cooled or maintained at a particular temperature This manual will provide an overview of the...

Страница 4: ...ressure vapor travels through a condenser where it dissipates heat to the environment The high pressure condensate then flows through an expansion valve which reduces the fluid s pressure and partiall...

Страница 5: ...plications If the unit is to be mounted remotely to cool an enclosure ductwork and a separting plate must be used as shown in Figure 2 3 Ductwork should be made as short as possible to minimize the im...

Страница 6: ...its lowest speed o Active Cooling mode If the air temperature is greater than the setpoint temperature the unit will run on normal cooling mode to achieve the setpoint temperature o Heating mode Optio...

Страница 7: ...12 hours 0 72 hours P97 Return to factory setting Pressing the S key will return the product to default factory settings Heating functions are optional and not included on all units The above paramete...

Страница 8: ...ervoltage warning E10 AC Power undervoltage warning E11 Refrigerant circuit pressure is too high warning E12 Refrigerant circuit pressure is too low warning E13 Heater current overload warning E14 Hea...

Страница 9: ...ing straps are unbroken and that the wooden box is undamaged not deformed or wet Use scissors or a knife to dismantle the packing belt then open the wooden box After opening the package please check t...

Страница 10: ...ed gasket Do not turn the unit on immediately after finishing the installation the unit must remain standing vertically for more than 30 minutes before being turned on to allow the compressor oil to d...

Страница 11: ...e All wires must be properly torqued to the relevant terminals All national wiring regulations and local electrical codes should be followed based upon instalation location Safety Reminder notes befor...

Страница 12: ...e IN N Line L Line Lighting Arrester CTRL NO COM NC T R T R INT Temp Sensor Cond Temp Sensor Inter Fan Exter Fan1 R S C Compressor 4 F 1 4 F 2 8 F J7 J8 J6 J32 J28 Evap Temp Sensor L Line J31 J30 rela...

Страница 13: ...wer supply voltage is normal and consistent with the requirements on the nameplate 6 2 Operating the Unit Apply power to the unit The product will first run a self test program and then the unit will...

Страница 14: ...arameter setting mode The display will show the Pxx code Use arrow keys to choose the desired item Press the S button to select The display will show the selected item s current parameter values use a...

Страница 15: ...the cable if damaged 2 Voltage Stability Use the multimeter to measure the Air Conditioner input voltage in order to gauge whether the voltage is within normal range If the voltage is not within the n...

Страница 16: ...larm stops Supply voltage overload The compressor current is not within the normal range Turn off the power supply immediately Use a multimeter to measure the voltage do not power on the switch until...

Страница 17: ...ve inspection test acceptance and use Seller s warranty shall run to Buyer its successors assigns and customers and users of products sold by Buyer Seller agrees to replace or correct defects of any G...

Страница 18: ...Rev A ACT VCC 5000 AC 18 IDEAL APPLICATIONS Questions or Comments ACT Quality Department quality 1 act com or call 717 295 6061 to reach the Sales staff for assistance on custom orders...

Отзывы: