BioSIMKey - ADT60 Reference Manual
rev 1.0, April, 2002
Advanced Card Systems Ltd.
Page 19 of 26
8.1.4 RESET
This section describes the
RESET
command only for the case when no card type is selected
or when the card type 00
H
is selected. For all other cases, please refer to the specific section
described for each individual card type.
Command format
Instruction Code
Data length
80
H
00
H
Response data format
ATR
ATR
The answer-to-reset string returned by the card.
The return status code for this command is 90 00
H
when the inserted card is a T=0 card, 90
01
H
when the inserted card is a T=1 card, and 90 10
H
when the inserted card is a memory
card; otherwise the status code is 60 20
H
.
8.1.5 SET_NOTIFICATION
This command disables / enables the Card Status Messages transmitted by the reader to
notify the host computer of the insertion or removal of a card.
Command format
Instruction Code
Data length
Data
NOTIFY
06
H
01
H
NOTIFY
Specifies whether the Card Status Message shall be transmitted to notify the
host computer of card insertion / removal
01
H
: transmit Card Status Message
02
H
: do not transmit Card Status Message
Response data format
No response data