Document Title Here
Document Title Here
Document Title Here
ACR33U-A1 SmartDuo Reference Manual
Version 1.00
Page 13 of 56
www.acs.com.hk
8.1.5.
PC_to_RDR_GetParameters
Get slot parameters.
Offset
Field
Size
Value
Description
0
bMessageType
1
6Ch
1
DwLength
4
00000
000h
Size of extra bytes of this message
5
BSlot
1
00-
05h
Identifies the slot number for this
command
6
BSeq
1
00-
FFh
Sequence number for command
7
AbRFU
3
Reserved for future use
The response to this message is the
RDR_to_PC_Parameters
message.
8.1.6.
PC_to_RDR_ResetParameters
Reset slot parameters to default value.
Offset
Field
Size
Value
Description
0
bMessageType
1
6Dh
1
DwLength
4
00000
000h
Size of extra bytes of this message
5
BSlot
1
00-
05h
Identifies the slot number for this
command
6
BSeq
1
00-
FFh
Sequence number for command
7
AbRFU
3
Reserved for future use
The response to this message is the
RDR_to_PC_Parameters
message.