ACS 882.03168.00 Скачать руководство пользователя страница 31

Compressed Air Dryer 

Chapter 7: Appendix 

31 of 31 

 

  Technical Assistance 

Parts Department 

Call toll-free 7am–5pm CST [800] 423-3183 or call [262] 641-8600 Fax: [262] 641-8653 
 
The  ACS  Customer  Service  Group  will  provide  your  company  with  genuine  OEM  quality  parts 
manufactured to engineering design specifications, which will maximize your equipment’s performance 
and  efficiency.    To  assist  in  expediting  your  phone  or  fax  order,  please  have  the  model  and  serial 
number of your unit when you contact us.  A customer replacement parts list is included in this manual 
for your convenience.  ACS welcomes inquiries on all your parts needs and is dedicated to providing 
excellent customer service.

 

Service Department 

 

Call toll-free 8am–5pm CST [800] 423-3183 or call [262] 641-8600  
Emergencies after 5pm CST, call [847] 439-5655 
 
We have a qualified service department ready to help. Service contracts are available for most  
products. Service contracts are available for most of our products.  www.acscustomerservice.com 

Sales Department 

Call [262] 641-8600 Monday–Friday, 8am–5pm CST  
 
Our products are sold by a world-wide network of independent sales representatives. Contact our Sales 
Department for the name of the sales representative nearest you.

 

Contract Department 

Call [262] 641-8600 Monday–Friday, 8am–5pm CST  
 

Let us install your system. The Contract Department offers any or all of these services: project planning; system packages 
including drawings; equipment, labor, and construction materials; and union or non-union installations. 

 
 
 
 

ACS Group 

2900 S. 160

th

 Street 

New Berlin, WI 53151 

 
 

 
 
 

 

Содержание 882.03168.00

Страница 1: ...Compressed Air Dryer Models ACD SCD Part Number 882 03168 00 Bulletin Number DRY1 600 00 Effective 03 2014...

Страница 2: ...___ _________________________ _________________________ _________________________ _________________________ We are committed to a continuing program of product improvement Specifications appearance an...

Страница 3: ...A certified copy of our invoice is available upon request The original Bill of Lading is attached to our original invoice If the shipment was prepaid write us for a receipted transportation bill Advis...

Страница 4: ...wpoint Operation Optional 11 2 8 Microprocessor Controls 12 Identifying the Controller s Buttons and Indicators 13 Understanding the Controller s Parameters 14 2 9 Restoring Factory Default Settings 1...

Страница 5: ...Compressed Air Dryer v CHAPTER 7 APPENDIX 26 7 1 Warranty 26 7 2 Technical Specifications 27 Dryer Operating Parameters 28 Dimensions 29 Spare Parts List 30...

Страница 6: ...ter includes a description of electrical and mechanical controls in addition to information for operating the dryer safely and efficiently The Maintenance chapter is intended to ensure that your dryer...

Страница 7: ...ty of the handling equipment or cause it to become unstable Carefully test the condition of lifting cables chains ropes slings and hooks before using them to lift a load Be sure that all on current ca...

Страница 8: ...ve safety guards Such alteration is not only unsafe but will void the warranty on your equipment When changing control settings to perform a different mode of operation be sure selector switches are c...

Страница 9: ...onsidered in the selection of your drying system including type of materials residence time throughput of the extruder or injection molding machine Should your operating environment change the manufac...

Страница 10: ...ty of the personnel operating and maintaining the equipment to familiarize themselves with the safety procedures and the proper use of any safety devices High Temperature Safety System A high temperat...

Страница 11: ...r of a second plastic that actually separates the water vapor from the air This second coating allows air to pass through it over 20 000 times easier than it allows water to pass As a result moisture...

Страница 12: ...sed PID temperature controller for maintaining process air temperature The controller is a modular self contained unit that you can remove from the mounting housing All parameters except for the proce...

Страница 13: ...to decrease the set point temperature during operation It also decreases the parameter values in set up modes Up Arrow button The Up Arrow button is used to increase the set point temperature during...

Страница 14: ...ariables that had been modified previously The default value is OFF Temperature Input Shift Tns Can be set from 199 9 to 999 9 This setting is used to offset an error between the set point and the act...

Страница 15: ...ng Factory Default Settings If the preset parameters on the controller have been tampered with and it no longer properly controls temperature and displays dew point you can restore the controllers to...

Страница 16: ...ount it to the hopper Note In some cases depending on the drying hopper model an adapter may not be required If an adapter is not required attach the dryer to the hopper with the clamps provided and i...

Страница 17: ...llowing procedure to connect a floor mount dryer to a hopper 1 Using the clamps provided clamp a hose adaptor onto the dryer and the hopper See Figure 4 Note Depending on the drying hopper model the c...

Страница 18: ...ressed air supply must be regulated to 80 PSI 5 5 bars Low air pressure will create poor drying performance If the pressure in the system drops below 35 PSI the alarm light will activate and the proce...

Страница 19: ...he inlet of the compressed air dryer 2 Attach the large particle filter including the close nipple to the membrane drying kit Note The membrane drying kit must have the large particle and the coalesci...

Страница 20: ...Mode Key one time The PV display will read At 3 Press the Up Arrow button to change the value to ON 4 Press the Level button to begin auto tuning and return to the Operation level The unit will automa...

Страница 21: ...Arrow button to change the value to RUN 8 Press the Mode button to begin operation 9 After the proper pre drying time for the initial hopper fill has elapsed fully open the drying hopper slide gate No...

Страница 22: ...ty 5 2 Cleaning and Replacing the Filters The 10 cfm compressed air dryer uses a large particle air filter in the process air system to clean the compressed air before it enters the drying cabinet The...

Страница 23: ...1 Make sure that the main power to the dryer is shut off and locked out 2 Locate the fuse holder that houses the fuse for the dryer see picture below for fuse holder location 3 Using a standard flat h...

Страница 24: ...nufacturer s data sheet for proper drying temperature Make sure plant personnel are aware of the correct process temperature set point High temperature alarm not set properly Reset high temperature al...

Страница 25: ...trol power fuse for continuity Turn disconnect switch and control power switch ON The key protection switch is set to ON Set the key protection switch to OFF Alarm light is on and unit has no air pres...

Страница 26: ...uipment to be returned Reason for requesting the return must be given All returns are to be shipped prepaid The invoice number and date or purchase order number and date must be supplied After inspect...

Страница 27: ...40 F 40 C Heating capabilities up to 400 F Large particle compressed air filter Exhaust air cartridge filter 1 16 DIN PID temperature controller High process temperature alarm light Automatic shutoff...

Страница 28: ...48 120 2 4 0 16 0 01 4 6 2 1 9 2 4 2 10 4 4 7 PE Filled 185 85 3 4 0 5 0 02 4 6 2 1 9 2 4 2 10 4 4 7 PE 194 90 1 2 0 05 0 01 7 3 2 14 6 4 15 8 7 1 PEEK 302 150 4 3 5 1 6 7 3 2 7 9 3 6 PEI 302 150 4 0...

Страница 29: ...Compressed Air Dryer Chapter 7 Appendix 29 of 31 Dimensions 13 4 339 12 25 311 7 3 185 12 305 15 7 398 6 8 172...

Страница 30: ...Parts not included in this list must be replaced by the factory Part No Quantity Description 35452 1 Filter Regulator 725 00002 00 1 Fuse 110 volt 725 00001 00 1 Fuse 220 1 50 725 00001 00 2 Fuse 230...

Страница 31: ...e Service Department Call toll free 8am 5pm CST 800 423 3183 or call 262 641 8600 Emergencies after 5pm CST call 847 439 5655 We have a qualified service department ready to help Service contracts are...