![ACS 882.02569.00 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/acs/882-02569-00/882-02569-00_mechanical-manual_2841775025.webp)
Maintenance
25
Chapter 5:
Maintenance
5-1 Work Rules
The installation, operation, and maintenance of this equipment is to be conducted in accordance
with all applicable work and safety codes for the installation location. This may include, but is not
limited to, OSHA, NEC, CSA, and any other local, national, and international regulations.
In addition, you must observe the following specific work rules:
þ
Keep these operating instructions on hand and follow them when installing, operating, or
maintaining your CDS System.
þ
If these instructions become damaged or unreadable, you can obtain additional copies
from the manufacturer.
þ
Only qualified personnel familiar with this equipment should work on or with this unit.
þ
Work only with approved tools and devices.
Disconnect power before servicing your dryer. If the disconnect switch you installed has a
lockout, lock it in the
OFF
position before you perform any maintenance or service.
5-2
Optional Damper Valve Maintenance
1.
Damper Valve Housing
2.
Bearing Flange
3.
12mm Shaft
4.
12mm Fastener
5.
Damper Valve
#822.99894.00
6.
Actuator #044.01245.00
7.
M6 Flat Washer
8.
0.25 Lock Washer
9.
M6x1.0x16 SBHCS
10.
M4x0.7x10 SBHCS