background image

07.17

Technical manual

Applications

General applications in

• 

Machinery and plant engineering

• 

Air-conditioning and refrigeration plant engineering

• 

Hydraulic and pneumatic systems

• 

Process industry

• 

Environmental technology

• 

Facility and building automation

Precont CT

Pressure transmitter for general applications

Monitoring of absolute or relative pressure 

in gases, vapors, liquids and dust

 

Main features

Wide range of applications

• 

Finely graded measuring ranges from 100 mbar up to 16 bar

• 

Wide process temperature range –40°C to +125°C

• 

Wide variety of process connections 

• 

High protection class IP69K/IP67

• 

Wide environmental temperature range –40°C to +85°C

• 

Certification ATEX II 1 G Ex ia IIB/IIC Tx Ga 

Ceramic front-flush diaphragm
High accuracy – characteristic deviation to ≤ 0,1% of measuring 

range
Integrated evaluation electronic

• 

Current output 4…20mA

• 

Voltage output 0…10V

• 

Connector plug M12

• 

Connector plug EN 175-301-803-C / -A

• 

Connection cable with integrated reference air capillary

Содержание Precont CT

Страница 1: ...in features Wide range of applications Finely graded measuring ranges from 100 mbar up to 16 bar Wide process temperature range 40 C to 125 C Wide variety of process connections High protection class...

Страница 2: ...al manual and the relevant standards and rules This expert must have read and understood this technical manual and especially the safety notes The device may only be used within the permitted operatio...

Страница 3: ...ssure from 0 8 bar to 1 1 bar If the device is operated beyond these atmospheric conditions the EU type examination certificate can be used as a guide Additional tests for the special application cond...

Страница 4: ...and environmental temperature The installation of the device should be made if possible at temperature calmed places to get a reliable measuring result Strong temperature steps e g at filling of a hot...

Страница 5: ...M12 drill hole besides the plug Plug EN 175 301 803 C plug socket Plug EN 175 301 803 A plug socket Cable capillary inside the cable At the version with cable the environmental air pressure is lead t...

Страница 6: ...lation place of the device 4 3 Supply voltage The voltage applied to the terminal contacts may not exceed the maximum permitted supply voltage see chapter Technical data to avoid damage of the electro...

Страница 7: ...1 Electronic output 2 wire current 4 20mA Plug M12 Conductor color standard connection cable M12 A coded BN brown BU blue Plug EN 175 301 803 Cable Conductor color cable RD red BK black GNYE greenyel...

Страница 8: ...CS CONTROL SYSTEMGmbHlLauterbachstr 57lD 84307Eggenfeldenlwww acs controlsystem delinfo acs controlsystem de 8 Plug EN 175 301 803 Cable Conductor color cable RD red BK black WH white GNYE greenyellow...

Страница 9: ...rmation s must be enclosed An exact description of the application The chemical and physical characteristics of the product A short description of the occurred error 6 4 Return Before returning the de...

Страница 10: ......

Отзывы: