Acroprint ARES III Скачать руководство пользователя страница 15

 

Assignments (Tab)

 

 
Before you commence assignments, please effect the following preparation and verification sequence: 
 
1.  Make a sketch of your premises and a list of all the sites (recording stations), elements and persons you want to control. 
2.  Sketch on hand; take a thorough tour of your premises (you might want to bring a Security Advisor along with you). 
3.  Note on your list, the 16-character serial number of each iButton to be installed (recording station), confronted with its actual matching installation 

site-name. 

4.  Your sketch will be useful when you proceed to assign and install all iButtons.  
5.  All Recording Stations are best installed at a height of 45 inches from the floor level. The use of water sealant around the plate edges is recom-

mended to protect the ink of the 

paper labels from being washed out during the rain season. 

Always use both mount plates.

 iButton mounts can be 

installed in walls, doors, furniture, fences, metal surfaces, trees, etc.  

 
The Assignments data Tab was designed for simplicity; with it you will able to effect all assignations of Recording Stations, Guards, Supervisors, plus 
whatever elements you desire to control. 

 

Pre-assigned System Messages: 

 
At first hand you will see 3 pre-assigned messages: 

• 

Battery Disconnected: Each time the battery of any of your recorders is disconnected, the recorder will record the Time & Date of the event. This 
message will appear on the 

Recordings Screen

 confronted with the recorder’s serial number and the time & Date of the event.  

• 

Isolated Message: Every time a guard reports an incident not related to a particular Recording Station this message will appear on the 

Recordings 

Screen

 confronted with the Date, Time and Message name. 

• 

Low Battery: Every time any of your recorders enters a low battery status, the recorder will record the Time & Date of the event, this message will 
appear on the Recordings Screen confronted with the Recorder Serial number and the Date & Time of the event. 

 
How to add a new data item; one by one (recommended procedure for beginners):  

 
1.  Select the Assignments Tab. 
2.  Connect your M4000 reader to the appropriate free (not in use) Serial Comm., port. 
3. Press 

the 

“NEW”

 button located in the button bar.  

4.  Read/Touch with your M4000 reader, the iButton you want to assign. At this point in time 

do not read / touch

 any of the Booklet iButtons. 

5. In 

the 

window 

“Name”,

 key in the Recording Station name, Watchman name, Supervisor name, Vehicle Registration Tag number or the name and/or 

number of whatever person or element/site you want controlled. 

6. 

In the window 

“Type”,

 select through the drop list, the type (group) to which the iButton belongs. These types or groups can be: Recording Station, 

Supervisor, Watchman, Vehicle, Etc. 

Press the 

Add Type

 Button or Right click your mouse on top of the 

“Type”

 window to “EDIT/ADD additional 

types (groups or categories). 

7.  (Only for Recording Stations): In the window 

“Area”,

 select through the drop list, the Tour Area to where you want the station assigned. 

Press the 

Add Area

 Button or Right click your mouse on top of the 

“Area”

 window to “EDIT/ADD additional Areas.

 

8. 

(Only for Recording Stations): Press the 

STATION SCHEDULE

 button. You will be able to schedule the station’s recordings per each day of the 

week, per each hour of the day (amount of times per hour you want this station visited). Press the 

Edit

 button, select the amount of recordings per 

hour on the drop list (arrow) and click on each cell. To select the same rate of recordings per hour for all hours of the day press the 

Set All

 button.

 

Содержание ARES III

Страница 1: ..._________________________________________________________________________ Page 18 Messages__________________________________________________________________________ Page 20 Recordings Report Configura...

Страница 2: ...he security business This program allows you to program patrols in a loose and ever changing pattern but simultaneously enables you to appropriately follow up and evaluate patrolling When Where What a...

Страница 3: ...gs 5460 64K into any IBM or compatible PC Pentium II 300 MHz or higher processor It is a sturdy device capable of withstanding rain mud grease dust severe radio interference and 100 G impacts The unit...

Страница 4: ...required Due to its great reliability the iButton developed and manufactured by DALLAS SEMICONDUCTOR has positioned itself solidly in the international market as a universal identifier of Persons Obj...

Страница 5: ...e of the ID Keys will en sure an appropriate and efficient operation of the system Who where what and when is critical data in the security business The ID keys are manufac tured in Nylon 66 provide a...

Страница 6: ...rectly associate the incident if the above sequence is not followed For isolated messages in other words messages that are not or should not be related to recording stations persons or elements the su...

Страница 7: ...mory This data when downloaded into the PC will produce all the necessary reports to evaluate guard performance Recording Station Assembly Mounts iButton Mounts iButtons are provided with a multipurpo...

Страница 8: ...reas Please remember an overworked and fatigued guard will not perform efficiently and his life will be endangered Guard displacements along their assigned areas should not always follow the same time...

Страница 9: ...alizing System Once the system is installed you may start the application The system will reside within the program group manager called Ares III the application is also named Ares III Double click on...

Страница 10: ...ts messages Recordings Archiving Password About and a Help Button Each time a Tab is selected its contents and function buttons will be displayed in the center of your screen Initially you will not re...

Страница 11: ...se please effect a full download of data to your PC and then erase the memory to reset now your reader will be ready for the next load cycle of 5460 new recordings Recorders Tab Here is where you setu...

Страница 12: ...button 3 Make sure the correct RS232 is selected 4 Select Clock Setup 5 Your M4000 Time Date and PC Time Date will be Synchronized Daylight Savings Setup 1 Select the Recorders or Recordings either o...

Страница 13: ...cordings 1 Select the Recorders or Recordings either of the two Tabs 2 Press the Download Program button 3 Make sure the correct RS232 is selected 4 Select Download 5 A normal full Download will take...

Страница 14: ...y or institution s name it will serve as the header for all your reports and listings This is very important Do not skip this step as the name you insert in this module will also conform the name of y...

Страница 15: ...onfronted with the Date Time and Message name Low Battery Every time any of your recorders enters a low battery status the recorder will record the Time Date of the event this message will appear on t...

Страница 16: ...me Supervisor name Vehicle Registration Tag number or the name and or number of whatever person or element site you want controlled 9 In the window Type select through the drop list arrow the type gro...

Страница 17: ...ee driver equipment etc The forth column displays the Tour Area name or number to which the recording stations have been assigned The fifth column dis plays the Recordings per Hour desired RPH for eac...

Страница 18: ...h key button 5 and press Enter or select OK Touch key button 6 and press Enter or select OK Touch key button 7 and press Enter or select OK Touch key button 8 and press Enter or select OK Touch key bu...

Страница 19: ...Booklets Keypads assignment...

Страница 20: ...place then record the code of the incident in the keypad where and what and finally re cord touch the E enter button For isolated messages in other words messages that are not or should not be relate...

Страница 21: ......

Страница 22: ...orts recordings by Message Code Type When selected all recordings will be sorted by Type Area Select to view all recordings sorted by Tour Area Watchman Select to view all recordings sorted per Watchm...

Страница 23: ...Name Will filter and display recordings by all one or more Names Recorder Will filter and display recordings by all one or more Recorders Messages Will filter and display recordings associated to all...

Страница 24: ...Filtered Report...

Страница 25: ...station has been left unattended The RPH row Recordings per Hour displays the amount of times per hour that a station has been visited by a specific guard The name of the guard will appear to the lef...

Страница 26: ...while touring The scope of its analysis is focused on each station Export You can export reports to any database or to Excel for further processing Data will be exported in a txt file format How to e...

Страница 27: ...you desire to protect your data select the Password Tab enter your password verify it and press OK The next time you attempt to enter the program it will request you to key in the password you previou...

Страница 28: ...ted by a mouse click will popup a screen presenting the user with a list of all backups The user can select the file to be restored by a double click or single click on the desired file and a click on...

Страница 29: ...de the proper operation of your system it is possible your databases are damaged Please close your Ares Watchman System and immediately run your Data Base Repair utility You will find it residing with...

Страница 30: ......

Страница 31: ...ab of this program also contains online Help To access click on the Tab of your choosing click on any of its components and press F1 About Contains vendor contact information software version and manu...

Отзывы: