5.0 SPECIFICATIONS
5.1 Physical
Height
(carrier to top of module components)
: 12.5 mm (0.4921 in) [MAX]
Board Thickness:
1.0 mm (0.03937 in)
Length x Width:
70.0 mm x 30.0 mm (2.76 in x 1.18 in)
Unit Weight
(not including shipping material)
: 10.8g (0.382 oz)
5.2 Power Requirements
5.3 Environmental Considerations
All modules have an operational temperature range of -40°C to 85°C
1,2
.
Note 1
: An air cooled application with an AcroPack module will require a
minimum airflow of 200LFM.
Note 2
: A conduction cooled application with an AcroPack module will
require purchase of the Heatsink
AP-CC-01
.
Table 5.1 Power Requirements
Summarized below are the expected current draws for each of the specified
power supply voltages.
Power Supply
Voltage
Current Draw (Idle/Typical)
1
3.3 VDC ± 5%
130/200mA
5.0 VDC ± 5%
NOT USED
1.5 VDC ± 5%
NOT USED
12 VDC ± 5%
NOT USED
-12 VDC ± 5%
NOT USED
Note 1
:
Idle current draw was measured with no external loopbacks or termination
installed and no active communication on any port.
Typical current draw was measured with external loopbacks, actively
running a loopback test using Exar Serial Super GUI Test Utility at 1Mbps
baud rate.
Summarized below are the operating temperature range, airflow and other
environmental requirements and applicable standards for the AcroPack
module.
5.3.1 Operating Temperature