SERIES AP440 ACROPACK  

USER

’S MANUAL 

 

 

 

Acromag, Inc. Tel: 248-295-0310  

          - 30 -                                   http://www.acromag.com  

- 30 - 

www.acromag.com 

 

and 6 select/indicate the bank as follows: 

Table 3.19 Bank Select (Write) 
& Status (Read) Register 

BIT 7 Bit 6 

BANK OF REGISTERS 

00 

Bank 0 – Read Input Signals 

01 

Bank 1 – Event Status/Clear 

10 

Bank 2 – Event Debounce Control, Reset, and Duration 

11 

INVALID – DO NOT WRITE 

 

Software Reset Register (Read/Write, Base + 44H)   

 

 

Writing a 1 to the bit 1 position of this register will cause a software reset to 
occur.  This bit is not stored and merely acts as a trigger for software reset 
generation (this bit will always read back as 0).  The Interrupt Enable Bit of 
the Interrupt Enable and Status register is not cleared in response to a 
software reset.  Bits 2-7 of this register are not used and will always read 
high (1’s). 

XADC Status/Control Register (Read/Write) - (BAR0 + 48H)   

 

This read/write register will access the XADC register at the address set in 
the XADC Address Register allowing the module’s key supply voltages and 
FPGA junction temperature to be monitored. 

For example, the address of the XADC Status register that is to be accessed 
is first set via the XADC Address register at BAR0 plus 0x4CH.  Next, this 
register at BAR0 plus 0x48H is read.  Bits 22 to 16 of this register hold the 
address of the XADC register that is accessed.  Data bits 15 to 6 of this 
register hold the “ADCcode” temperature, Vccint, or Vccaux value.  Data bits 
5 to 0 are not used.  Valid addresses are given in column one of the table 
below. 

Reading or writing this register is possible via 32-bit data transfers. 

The 10-bits digitized and output from the ADC can be converted to 
temperature by using the following equation. 

15

.

273

1024

975

.

503

)

(

ADCcode

C

e

Temperatur

 

The 10-bits digitized and output from the ADC can be converted to voltage 
by using the following equation. 

V

ADCcode

volts

age

SupplyVolt

3

1024

)

(

 

 

 

Содержание Acropack AP440 Series

Страница 1: ...Module With Interrupts USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 2417 U S A Tel 248 295 0310 Fax 248 624 9234 Copyright 2016 Acromag Inc Printed in the USA Data and spec...

Страница 2: ...3 1 Ordering Information 5 1 3 2 Key Features 5 1 3 3 Key Features PCIe Interface 6 1 4 Signal Interface Products 7 1 5 Software Support 7 Windows 7 VxWorks 7 Linux 7 1 6 References 8 2 0 PREPARATION...

Страница 3: ...26 Event Interrupt Status Register for Ports 0 3 Enhanced Mode Bank 1 Port 6 Read Only 26 Table 3 13 Event Interrupt Status Register for Ports 0 3 26 Event Polarity Control Register For Ports 0 3 Enha...

Страница 4: ...ervice and Repair Assistance 38 5 2 Preliminary Service Procedure 38 5 3 Where to Get Help 38 6 0 SPECIFICATIONS 40 6 1 Physical 40 6 2 Power Requirements 40 6 3 Environmental Considerations 40 6 3 1...

Страница 5: ...ticular purpose Further Acromag assumes no responsibility for any errors that may appear in this manual and makes no commitment to update or keep current the information contained in this manual No pa...

Страница 6: ...olarity debounce and interrupt support Inputs also include hysteresis for increased noise immunity The AP440 utilizes state of the art Surface Mounted Technology SMT to achieve its wide functionality...

Страница 7: ...ust pass before the input transition is recognized as valid at the FPGA input This helps prevent false events and increases noise immunity Reverse Polarity Protection Bipolar inputs are not polarized...

Страница 8: ...consists of low level drivers and Dynamic Link Libraries DLLs that are compatible with a number of programming environments The DLL functions provide a high level interface to boards eliminating the n...

Страница 9: ...www acromag com 8 www acromag com 1 6 References The following resources regarding AcroPack modules are available for download on Acromag s website or by contacting your sales representative PCI Expre...

Страница 10: ...etic or radioactive fields unless the device is contained within its original manufacturer s packaging Be aware that failure to comply with these guidelines will void the Acromag Limited Warranty 2 1...

Страница 11: ...should be given to air filtering In a conduction cooled assembly adequate thermal conduction must be provided to prevent a temperature rise above the maximum operating temperature 2 3 Board Configura...

Страница 12: ...3 3 5 10 NC 37 28 6 9 Field I O 5 12 Reserved isolation 11 Reserved isolation 4 4 7 14 Field I O 6 38 29 8 13 Field I O 7 16 Reserved isolation 15 Reserved isolation 5 5 9 18 Field I O 8 39 30 10 17...

Страница 13: ...O 22 48 39 28 53 Field I O 23 56 Reserved isolation 55 Reserved isolation 15 15 29 58 Field I O 24 49 40 30 57 CCOM 60 Reserved isolation 59 Reserved isolation 16 16 31 62 Field I O 25 50 41 32 61 Fi...

Страница 14: ...5 NC 88 Reserved isolation 87 Reserved isolation 23 23 45 90 NC 57 48 46 89 NC 92 Reserved isolation 91 Reserved isolation 24 24 47 94 NC 58 49 48 93 NC 96 Reserved isolation 95 Reserved isolation 25...

Страница 15: ...dule Likewise pin assignments are identical to those of Acromag Model AP408 Note that the inputs of this device are bipolar and may be connected in any polarity with respect to the port common Further...

Страница 16: ...ule carriers and conduction cooling kit to provide additional stability for harsh environments Power supplies 5 12 and 12 Volt have been assigned to pins that are reserved in the mini PCIe specificati...

Страница 17: ...COEX1 1 4 GND 1 N C WAKE 1 2 3 3V3 Note 1 The following mini PCIe signals are not used by the AP440 USB_D USB_D WAKE LED_WPAN LED_WLAN LED_WWAN W_DISABLE COEX1 COEX2 UIM_C4 UIM_C8 Note 2 5 12 and 12 V...

Страница 18: ...card The system software accesses the configuration registers to determine how many blocks of memory space the module requires It then programs the board s configuration registers with the unique memo...

Страница 19: ...at the base address for the board BAR0 in memory space must be added to the addresses shown to properly access these AP440 registers Register accesses as 32 16 and 8 bit data in memory space are permi...

Страница 20: ...to determine the function required Standard Default Mode Memory Map Table 3 2 shows the memory map for the Standard Mode of operation This is the Default mode reached after power up or system reset S...

Страница 21: ...08 IN15 0x0000 0010 7 0 READ1 Port 2 Register IN16 IN23 0x0000 0014 7 0 READ1 Port 3 Register IN24 IN31 0x0000 0018 7 0 NOT USED2 0x0000 001C 7 0 NOT USED2 0x0000 0020 7 0 NOT USED2 0x0000 0024 7 0 RE...

Страница 22: ...18 7 0 NOT USED2 0x0000 001C 7 0 NOT USED2 0x0000 0020 7 0 NOT USED2 0x0000 0024 7 0 READ Port 7 Current Bank Status 0x0000 0024 7 0 WRITE Port 7 Bank Select Register 0x0000 0028 0x00000040 31 0 NOT U...

Страница 23: ...ent Bank Status Reg 0x0000 0024 7 0 WRITE Port 7 Bank Select Register 0x0000 0024 7 0 WRITE Port 7 Also Bank Select Register 0x0000 0028 0x00000040 31 0 NOT USED2 Table 3 6 Enhanced Mode Bank 2 Memory...

Страница 24: ...hen both enabled will allow interrupts to be generated Changing Debounce control registers while interrupts are enabled can cause false interrupts It is recommended that interrupts be disabled prior t...

Страница 25: ...rt assigns the least significant data line D0 to the least significant input line of the port grouping e g IN00 for port 0 to D0 A read of this register returns the status ON OFF of the input point Do...

Страница 26: ...ent Sense Status Clear Registers For IN00 IN31 Enhanced Mode Bank 1 Ports 0 3 Read Write Each input line of each port includes an event sense input Reading each port will return the status of each inp...

Страница 27: ...atus of input ports 0 3 bits 0 3 and the interrupt status flag bit 7 Bit 7 of this register indicates an event sense was detected on any of the 4 event sense ports 1 interrupt asserted event sensed No...

Страница 28: ...rough IN31 Bank Select Register Enhanced Mode Bank 1 Port 7 Write Only Bits 6 7 of this register are used to select monitor the bank of registers to be addressed In Enhanced Mode three banks banks 0 2...

Страница 29: ...nput ports or event signals to insure valid data Table 3 17 Debounce Control Register Note that any registers bits not mentioned will remain at the default value logic low Bit s FUNCTION 0 Port 0 IN00...

Страница 30: ...e Bank 2 Port 3 Write Only This register bit is used to reset the debounce circuitry If bit 0 of this register is 0 default value the debounce circuitry is not reset If bit 0 is set to 1 then the inte...

Страница 31: ...r Read Write BAR0 48H This read write register will access the XADC register at the address set in the XADC Address Register allowing the module s key supply voltages and FPGA junction temperature to...

Страница 32: ...m Temperature 0x25 Minimum Vccint 0x26 Minimum Vccaux Table 3 21 FPGA Voltage and Temperature Range Symbol Minimum Typical Maximum Vccint 0 95 1 0 1 05 Vccaux 1 71 1 8 1 89 Recommended Operating Tempe...

Страница 33: ...t lines a port are isolated and gated to the data bus D0 D7 lines A high input will read as 1 and all inputs include hysteresis and programmable debounce Enhanced Operating Mode In the Enhanced Mode o...

Страница 34: ...be detected On the AP440 if change of state detection for an input signal is desired two channels connected to the same input signal would be required one sensing positive transitions one sensing neg...

Страница 35: ...ut point while the state refers to its current level An enabled Event Sense bit and the board interrupt enabled when both enabled will allow interrupts to be generated Changing Debounce control regist...

Страница 36: ...tting bit 0 of the Debounce Control Register Write 01H to the Port 0 address of this bank Debounce Control Register If the module had been configured earlier you would first read this register to chec...

Страница 37: ...errupt Enable bit 0 1 To enable further interrupts to occur for an event that has already occurred for an I O point the Event Sense Status Register must be written with a 1 to reenable event sensing f...

Страница 38: ...ingle port share a common connection individual outputs are not isolated from each other within the same port However separate port commons are provided to facilitate port to port isolation Input opto...

Страница 39: ...ON POWER MUST BE TURNED OFF BEFORE SERVICING BOARDS Before beginning repair be sure that all of the procedures in the Preparation for Use section have been followed Also refer to the documentation of...

Страница 40: ...SERIES AP440 ACROPACK USER S MANUAL Acromag Inc Tel 248 295 0310 39 http www acromag com 39 www acromag com Email solutions acromag com Phone 248 295 0310...

Страница 41: ...AC peak 40oC to 85oC1 2 AP440 3E LF 38V to 60V DC or AC peak 40oC to 85oC1 2 Note 1 An air cooled application with an AcroPack module will require a minimum airflow of 200LFM Note 2 Applications requi...

Страница 42: ...trength test for one minute without breakdown 6 3 4 Vibration and Shock Standards The AcroPack complies with the following Vibration and Shock standards Vibration Sinusoidal Operating Complies with IE...

Страница 43: ...an appropriate pullup to 5V Input Hysteresis 80mV Typical Input Capacitance 45pF Typical Turn On Time Measured to the point of positive event interrupt detection 15us Typical 25 C for a 0 to threshol...

Страница 44: ...1 Line Speed Gen1 2 5Gbps Available through system connector Lane Operation 1 Lane 4K Memory Space Required One Base Address Register BAR Input Current Varies according to model number and input signa...

Страница 45: ...er is 20 Bytes with data payload of 4 Bytes for our typical AcroPack For each 4 Byte data sample 24 Bytes are sent 10 4 M samples sec or 41 6 M Bytes sec or 0 332 G bit sec Note 3 For our typical Acro...

Страница 46: ...Tel 248 295 0310 45 http www acromag com 45 www acromag com Appendix A AP CC 01 Heatsink Kit Installation This example will show how to install the AP CC 01 Heatsink kit with an APCe7020 carrier AP CC...

Страница 47: ...ACK USER S MANUAL Acromag Inc Tel 248 295 0310 46 http www acromag com 46 www acromag com 1 Install two standoffs and secure with two screws 2 Install the AcroPack module 3 Install the Heatsink and se...

Страница 48: ...S AP440 ACROPACK USER S MANUAL Acromag Inc Tel 248 295 0310 47 http www acromag com 47 www acromag com 4 AP CC 01 Installation is complete Note Make sure the thermal pad is making contact with the FPG...

Страница 49: ...ATED INPUT I O INTERFACE SIMPLIFIED INPUT CHANNEL NOTE FOUR PORTS OF EIGHT CHANNELS ARE PROVIDED SEPARATE PORT COMMONS ENSURE PORT TO PORT ISOLATION IO31 INPUT VOLTAGE RANGE AP440 1 4 18V DC OR AC PEA...

Страница 50: ...N AP440 PORT AND THE COMMON LINE OF AN AP445 PORT DO NOT NECESSARILY CONNECT TOGETHER THE AP440 AP445 INCLUDE 4 PORTS OF 8 CHANNELS EACH EACH PORT SHARES A PORT COMMON SEPARATE PORT COMMONS FACILITATE...

Страница 51: ...itize Power Down Type SRAM SDRAM etc Size User Modifiable Yes No Function Process to Sanitize Non Volatile Memory Does this product contain Non Volatile memory i e Memory of whose contents is retained...

Страница 52: ...tion of Revision 11 17 2015 Preliminary LMP LMP Preliminary Document Publication 7 19 2016 A LMP MJO Document Publication 8 02 2016 B LMP MJO Port to Port Isolation voltage added 10 05 2016 C LMP MJO...

Отзывы: