ACR STOVES Tenbury T400ECO Скачать руководство пользователя страница 2

Important!

• Before installation and/or use of this

appliance please read these instructions
carefully to ensure that all requirements are
fully understood.

• This appliance must be installed by a

registered engineer, or approved by building
control, failure to do so may endanger life and
property.

• All the instructions in this manual should work

in conjunction with building regulations
document J, if there is a variation the most
stringent requirement should be adhered to.

• The installation of this appliance must comply

with current Building Regulations and local
regulations, including those referring to
national and European standards need to be
complied with when installing the appliance.

• Do not operate this appliance if it becomes

damaged.

• Improper use, maintenance or fitting parts

other than those approved by the
manufacturer could lead to the appliance
becoming damaged or unsafe which in turn
could lead to personal injury or damage to
the property and will void the warranty.

• The appliance must not be modified in

anyway unless authorised by ACR Heat
Products Ltd.

• The appliance should be inspected regularly

to ensure the airways are clean and free from

obstruction and the chimney swept at least
once a year.

• The external surfaces of this appliance will be

very hot to the touch when in operation and
due care will need to be taken when
operating the appliance to ensure safety. A
fire guard should be fitted if it is likely that the
elderly, infirm or children may come into
contact with the appliance.

• This appliance has been designed for

intermittent operation. 

• This appliance must not be used as an

incinerator.

• Each installation is unique to the property, the

information contained in this manual may not
give exact installation requirements for your
installation.

• The installation must comply with Building

Regulations, European Standards and Local
authority bylaws. Asbestos This appliance
contains no asbestos, if there is the
possibility of disturbing any asbestos in the
installation of this appliance then specialist
advise must be sought and appropriate
precautions taken. Metal Parts This appliance
may contain sharp metal edges, take care
when installing or servicing this appliance to
avoid personal injury. Please use appropriate
personal protective equipment at all times.

To ensure that you gain the most from your purchase, please take a few minutes

to read through this manual before lighting the appliance for the first time.

Since April 2002 only registered competent installers can install solid fuel appliances. Installations

carried out by non-registered installers must be inspected by local authority building control. 

For more information please contact hetas at: www.hetas.co.uk or telephone: 0845 6345626

Before installation, please ensure that the correct model has been supplied. 

Please make a note of the serial number of your appliance in the space provided on the front cover of

this manual as this will be requested if you require technical assistance in the future.

Please also ensure that the commissioning checklist at the rear of the manual is completed in full.

2

Tenbury T400 install manual NEW 2020-0320-7  16/03/2020  14:05  Page 2

Содержание Tenbury T400ECO

Страница 1: ...rence Thank you for purchasing an ACR Heat Products stove T E C H N I C A L M A N U A L Document T400ECO 0101 Version 1 Date 02 03 20 Serial Number MULTI FUEL DEFRA EXEMPT AIRWASH SYSTEM 10 YEAR 10 YE...

Страница 2: ...contact with the appliance This appliance has been designed for intermittent operation This appliance must not be used as an incinerator Each installation is unique to the property the information co...

Страница 3: ...initial 3 minutes Height 550 mm Internal Box 588 mm External Trim Width 396 mm Internal Box 470 mm External Trim Depth 337 mm Recessed 347 mm External Trim Weight 60 kg Air Requirement N A Flue Mass G...

Страница 4: ...Technical Data Declaration of Performance 4 Tenbury T400 install manual NEW 2020 0320 7 16 03 2020 14 05 Page 4...

Страница 5: ...16 of the Environmental Better regulation Act Northern Ireland 2016 In Wales appliances are exempted by regulations made by Welsh Ministers The Tenbury T400Eco has been recommended as suitable for us...

Страница 6: ...od This appliance must be installed by a registered engineer or approved by building control failure to do so may endanger life and property All the below instructions should work in conjunction with...

Страница 7: ...onstructed of a non combustible material i e metal studwork Do not use combustible materials within the chequered area 200mm to the sides of the appliance and 300mm to the rear of the appliance Do not...

Страница 8: ...ce Flue Requirements The flue must comply with current Building Regulations Document J The construction of masonry flue block insulated flue systems and flexible flue liners must comply with the manuf...

Страница 9: ...place and replace the 6 x 10mm screws replace the baffle and install the trim if not already in place 3 4 5 6 7 8 Operating your stove Using your appliance for the first time To allow the appliance t...

Страница 10: ...combustion of the wood logs Open the secondary air slider to the left hand side of the door and open the primary air slider to the right hand side of the door by fully pushing the levers inwards Lay f...

Страница 11: ...Fuel overloading Never overload the stove it will work very well with two medium sized logs The amount of fuel specified in this manual should not be exceeded overloading can cause excess smoke Glass...

Страница 12: ...ite panels of the appliance should be checked regularly for soundness If any wear and tear is found we recommend these parts are replaced immediately Check the rope door seals are intact and are not w...

Страница 13: ...l starts to crumble and fall apart in chunks To prevent the issue from happening and prolong the life of your internal panels the homeowner should burn in the refractory panels in the new appliance by...

Страница 14: ...ke test Record flue draught reading Spillage test preformed in accordance with available guidance Check socket joints and seals on the flue and appliance Instruct user on correct fuels and fuel storag...

Страница 15: ...top removing tool 11 TB 02 11 05A Primary air slider 12 TB 02 11 04A Secondary Tertiary air slider 13 TB 02 30 01A Left hand vermiculite panel 14 TB 02 30 03A Right hand vermiculite panel 15 TB 02 30...

Страница 16: ...easoned wood 20 moisture content Low flue draught Consult your installer for advice on suitable flue system Incorrect use of air control See user instructions for correct use of air control Appliance...

Страница 17: ...t your installer for advice on suitable flue system Incorrect additional ventilation air into building Consult your installer Continuous smoke spillage into room when appliance in use Blocked flue Ope...

Страница 18: ...Address Postcode Daytime Tel Mobile Tel Model Name Model Number Serial Number Date of purchase Date of installation Installer s Name and address Installer s Registration Number Building Control Certif...

Страница 19: ...ordance with our instruction manual All Stoves are covered by a 10 year warranty which covers all stove body castings stove body steel panels It does not include consumable items such as glass door se...

Страница 20: ...ted Unit 1 Weston Works Weston Lane Tyseley Birmingham B11 3RP England Tel 0121 706 8266 E mail enquiries acrheatproducts co uk www acrheatproducts co uk Tenbury T400 install manual NEW 2020 0320 7 16...